Hardware overview
The storage system consists of a controller chassis and one or more drive chassis mounted in a 19-inch rack.
Controller chassis
The controller chassis contains the following components:
- Controller boards (CTLs, also called DKCs.)
- Front-end modules (FEMs), also called channel boards (CHBs)
- Back-end modules (BEMs), also called disk boards (DKBs)
- Power supply (PS)
- Backup fan module (BKMF)
- Accelerator FAN Module (ACFL)
The CTLs contain the cache memory (CM) and cache flash memory (CFM) for the storage system. The VSP E1090 supports 1,024 GiB of cache memory.
Number | Item | Description |
1 | LED (POWER, READY, WARNING, ALARM) | Status LEDs for the controller chassis. |
2 | POWER ON/OFF (main switch) |
Switch that controls power to the storage system. |
3 | Lock | Use to lock and unlock front bezel. |
Number | Item | Description |
1 | POWER LED | Green: Storage system is powered on. Amber: Storage system is receiving power. |
2 | READY LED | Green: Normal operation. |
3 | WARNING LED | Off: Normal operation. Amber: Component requires maintenance. Blink: Failure requires maintenance. Note: When system option mode (SOM) 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIMs) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. |
4 | ALARM LED | Off: Normal operation. Red: Processor failure (system might be down). For assistance, contact customer support: https://support.hitachivantara.com/en_us/contact-us.html. |
Number | Item | Description |
1 | Controllers | Controller 1 (bottom) and Controller 2 (top). |
2 | Backup module | N/A |
3 | BACKUP LED | Green: Power restoration in progress following
power outage. Fast blink green: Restoring. Slow blink green: Restoring, or sequential shutdown in progress. |
4 | Cache flash memory | N/A |
5 | ALM LED (for cache flash memory) | Red: Cache flash memory can be removed. |
6 | CTL ALM LED | Red: Controller can be removed. Blink red: Failure with the power supply unit of the controller. Amber: LAN reset switch was pressed. |
7 | LAN-RST switch | Use only when instructed by customer support. |
8 | STATUS LED (for BKMF) | Green: Charging of the battery in the backup
module is complete. Red: Backup module can be removed. Blink red one time: Main battery failure. Blink red two times: Backup battery failure. Blink red three times: Both batteries failed or preventive maintenance replacement of batteries can run. Off: Battery is not mounted, battery-mounting failure occurred, or firmware is being upgraded. Off is normal status for configurations without batteries. |
9 | POWER ON/OFF (main switch) | Powers the storage system. |
10 | POWER, READY, WARNING, and ALARM LEDs | Note: When system option mode (SOM) 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIMs) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. |
Number | Item |
1 | Power supply |
2 | Disk board module |
3 | LAN board |
4 | Channel board module |
Number | Item | Description |
1 | ALM / RDY LED | Red: Power supply unit can be replaced. |
2 | RDY LED | Green: Normal operation. |
Controller board
Number | Item | Description |
1 | STATUS | LED Off: Battery is uninstalled, installed
improperly or BKMF firmware is replaced (in case of a configuration
with no battery installed, the LEDs for BKMF-10 and BKMF-20 go out).
Green On: Battery is fully charged. Green Blinking: Battery is charged or discharged. Red On: BKMF has an error. Red Blinking: BKMF can be removed. A failure occurred in the battery or preventive maintenance replacement of the batteries is possible. |
2 | LAN-RST | This is a switch for GUM reset. If GUM reboot fails, reset GUM forcibly from the hardware. |
3 | CTL ALM | Red On: The controller board is ready to be removed
(when the maintenance work requiring insertion and removal of the
controller board is performed). A failure is detected in the
controller board (when the maintenance work mentioned above is not
performed). Red Blinking: A failure is detected in the controller board, cache memory, or cache flash memory (CFM). Amber On: Indicates that the LAN RESET switch is pressed. |
4 | BACKUP STS | Green On : Indicates that power
outage has occurred or power restoration is in progress after power
outage.
|
5 | ALARM | Red On: Cache Flash Memories are removable. |
Number | Item | Description |
1 | ACT/LINK LED | Amber: Link status/data transfer status. |
2 | SPEED LED | On: Link speed = 1 Gbps. Off: Link speed = 10 Mbps/100 Mbps. |
3 | LAN ALARM LED | Red: The removal of the LAN Board is possible. |
Front-end modules
The front-end modules (FEMs), also called channel boards (CHBs), control the transfer of data between the host and cache memory. The storage system supports Fibre Channel (FC) and iSCSI front-end modules (FEMs) for attachment to host servers. The front-end module LEDs indicate the operating status of the module.
Specification | Fibre 32-Gbps Ready | iSCSI 10G | iSCSI 10G BASE-T | |
Model number | DKC-F910I-4HF32R | DKC-F910I-2HS10S | DKC-F910I-2HS10B | |
Number of PCBs | 1 | 1 | 1 | |
Host interface | FCP | iSCSI (optical) | iSCSI (copper) | |
Data transfer rate (MB/s) | 16Gbps: 400/800/1,600 32Gbps: 800/1,600/3,200 | 1,000 | 100/1,000 | |
Number of options installed( ): DKB slot used | 2/4/6/8/12/14/16 (14/16/18/20) | 2/4/6/8/12/14/16 (14/16/18/20) | 2/4/6/8/12/14/16 (14/16/18/20) | |
Number of ports per PCB | 4 | 2 | 2 | |
Number of ports per storage system( ): DKB slot used | 8/16/24/32/48/56/64 (56/64/72/80) | 4/8/12/16/24/28/32 (28/32/36/40) | 4/8/12/16/24/28/32 (28/32/36/40) | |
Maximum cable length | Short wave1 | 400m/190m/125m/100m | 550m | - |
Long wave | 10km | - | - | |
Copper | - | - | 50m (cat 6a) | |
|
10-Gbps iSCSI board LEDs and connectors (optical)
Number | Item | Description |
1 | STATUS LED | Green: Front-end module is in the
power-on state. Red: Front-end module can be removed safely. |
2 | PORT LED | Red: Small-form factor (SFF) pluggable can be removed. Blue: Normal link status. Blue Blinking: Front-end module is in communication status. |
3 | iSCSI connectors | Connect to Ethernet cables. |
10-Gbps iSCSI board LEDs and connectors (copper)
Number | Item | Description |
1 | STATUS LED | Green: Front-end module is in the
power-on state. Red: Front-end module can be removed safely. |
2 | PORT (Link/Speed) LED | Yellow: 1-Gbps link. Green: 10-Gbps link. Off: No link connection. |
3 | PORT LED | Green: Link connection is
established. Blinking: Communication is in progress. Off: No link connection or not ready to communicate. |
4 | iSCSI connectors | Connect to Ethernet cables. |
16-Gbps or 32-Gbps Fibre Channel (4-port) board LEDs and connectors
Number | Item | Description |
1 | Fibre Channel connectors | Connect to Fibre Channel cables. |
2 | STATUS LED | Green: Front-end module is in
power-on state. Red: Front-end module can be removed safely. |
3 | PORT LED | Red: Small-form factor (SFF) pluggable can be removed. Blue: Normal link status at 16 Gbps (16 Gbps). Blue: Normal link status at 32 Gbps (32 Gbps). Green: Normal link status at 4 Gbps or 8 Gbps (16 Gbps). Green: Normal link status at 8 Gbps or 16 Gbps (32 Gbps). |
The following table lists the Fibre Channel port assignments
CHB number | 16-Gbps, or 32-Gbps Fibre Channel ports (left to right) | |||
Port 1 | Port 2 | Port 3 | Port 4 | |
CHB-1A | 1A | 3A | 5A | 7A |
CHB-1B | 1B | 3B | 5B | 7B |
CHB-1C | 1C | 3C | 5C | 7C |
CHB-1D | 1D | 3D | 5D | 7D |
CHB-1E | 1E | 3E | 5E | 7E |
CHB-1F | 1F | 3F | 5F | 7F |
CHB-1G | 1G | 3G | 5G | 7G |
CHB-1H | 1H | 3H | 5H | 7H |
CHB-2A | 2A | 4A | 6A | 8A |
CHB-2B | 2B | 4B | 6B | 8B |
CHB-2C | 2C | 4C | 6C | 8C |
CHB-2D | 2D | 4D | 6D | 8D |
CHB-2E | 2E | 4E | 6E | 8E |
CHB-2F | 2F | 4F | 6F | 8F |
CHB-2G | 2G | 4G | 6G | 8G |
CHB-2H | 2H | 4H | 6H | 8H |
Back-end modules
The back-end modules (BEMs), also called disk boards (DKBs), control the transfer of data between the drives and cache memory. The back-end module LEDs indicate the operating status of the module.
Item | Specification |
Model number | DKC-F910I-BN8G |
Number of PCBs | 1 |
Number of ports per PCB | 4 |
Performance | 8 Gbps |
Data encryption | Not supported |
Number of PCBs per storage system | 4 or 8 |
Number of NVMe ports per system | 8 or 16 |
Number | Item | Description |
1 | STATUS LED | Green: Back-end module is in the power-on state. Red: Back-end module can be removed safely. |
2 | PORT LED | Blue: Link status is normal. |
3 | PATH 0 connector | Connect to a drive tray. |
4 | PATH 1 connector | Connects to a drive tray. |
LAN blade LEDs and connectors
Number | Item | Description |
1 | LINK LED | Green: Link status is normal. |
2 | ACT LED | Orange: Data is being transferred. |
3 | LAN 2 | LAN port used by the user. |
4 | LAN 1 | Maintenance LAN port used by service personnel. |
5 | LAN ALARM LED | Red: LAN blade can be removed. |
6 | Uninterruptible power supply (UPS) port | N/A |
PCIe module
Number | Item | Description |
1 | STATUS LED | Green: PCIe module is in the power-ON status. Red: PCIe module failure occurred. Off: PCIe module can be removed safely. |
2 | Link | Green: PCIe is Gen-3 (8-Gbps) and is linked up normally. Off: PCIe is not linked up (PCIe cable might not be connected). If a PCIe cable is connected, it can be removed safely. |
NVMe drive tray (DBN)
The following table describes the physical specifications of the NVMe drive tray.
Name |
Model name |
Height |
Number of drive slots |
Drive type |
DBN |
DW-F850-DBN |
2U (88.2 mm) |
24 |
2.5 inch |
DBNE |
DW-F1000-DBNE |
2U (88.2 mm) |
24 |
2.5 inch |
NVMe display LEDs
Number | Item | Description |
1 | ALM | Red: Indicates that the removal of the HDD/SSD is possible when the storage system is powered on. |
2 | ACT | Green: Indicates that the drives are powered on. Blinking Green: Indicates that the drives are active. |
3 | POWER | Green: Indicates that power is supplied to the ENC. |
4 | READY | Green: Indicates that the ENC is operating normally. |
5 | LOCATE | Amber: An LED to specify the chassis location on the
rear of the chassis. The LED can be lit/turned off by Maintenance Utility. |
NVMe rear panel
Number | Item | Description |
1 | POWER | Green: Indicates that power is supplied to the ENC. |
2 | LOCATE | Amber: An LED to specify the chassis location on
the rear of the chassis. The LED can be lit/turned off by Maintenance Utility. |
3 | ALARM | Red: Indicates that the removal of the drive is possible when the storage system is powered on. |
4 | LINK | Blue: Indicates that PCIe between DKBN and ENC is linked up. |
NVMe AC power supply LED
Number | Item | Description |
1 | RDY2 | Green: Normal operation Off: Erroneous operation or out of operation |
2 | RDY1 | Green: Normal operation Off: Erroneous operation or out of operation |
3 | AC IN | Green: Indicates that AC input is normal. |
4 | ALM (REPLACE) | Red: Indicates when the power supply can be replaced. |
Small-form-factor drive tray (DBS)
The following table describes the physical specifications of the small-form-factor drive tray.
Name |
Model name |
Height |
Number of drive slots |
Drive type |
DBS |
DW-F1000-DBS |
2U (88.2 mm) |
24 |
2.5 inch (SFF) |
DBSE |
DW-F1000-DBSE |
2U (88.2 mm) |
24 |
2.5 inch (SFF) |
SFF front panel with bezel
Number | Item | Description |
1 | POWER LED |
Green: Drive tray is powered on. |
2 | READY LED |
Green: Drive tray is operational. |
3 | Locate LED |
Amber:
|
4 | Lock |
Locks and unlocks the front panel bezel by using the supplied key. |
SFF front panel without bezel
Number | Item | Description |
1 |
POWER, READY, and LOCATE LEDs |
Green: Drive tray is powered on. |
Green: Drive tray is operational. | ||
Amber:
| ||
2 |
ALM LED | Red: Drive stopped due to a failure and can be replaced. |
3 |
ACT LED |
Green: Normal operation. Blink green: Drive is being accessed. |
4 | Small-form-factor drives |
The twenty-four 2.5-inch SFF drives are positioned vertically. The slots are organized from 0 to 23. |
SFF rear panel
Number | Item | Description |
1 | ENC | N/A |
2 | POWER LED |
Green: ENC is in the power-on state. |
3 | Locate LED |
Amber:
|
4 | ALARM LED |
Red: ENC can be replaced. |
5 | PATH (IN) LED |
Blue: IN side port is linked up. |
6 | PATH (IN) connector |
Connects to a controller or drive tray. |
7 | PATH (OUT) LED |
Blue: OUT side port is linked up. |
8 | PATH (OUT) connector |
Connects to a drive tray. |
9 | Console |
This port is reserved. |
10 | Power supply unit | N/A |
11 | Receptacle |
Connects to the power cable provided with the storage system. |
12 | AC IN LED |
Green: Normal operation. |
13 | ALM LED |
Red: Power supply unit can be replaced. |
14 | RDY LED |
Green: Normal operation. |
AC power supply unit LEDs and connectors
Both SFF and LFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display their operating status.
Number | Item | Description |
1 | RDY LED |
Green: Normal operation. |
2 | ACI IN LED |
Green: AC input is operating normally. |
3 | ALM LED |
Red: Power supply unit can be replaced. |
Small-form-factor drive tray (DBS2)
The following table describes the physical specifications of the small-form-factor drive tray.
Name |
Model name |
Height |
Number of drive slots |
Drive type |
DBS2 |
DW-F1000-DBS2 |
2U (88.2 mm) |
24 |
2.5 inch (SFF) |
DBS2E |
DW-F1000-DBS2E |
2U (88.2 mm) |
24 |
2.5 inch (SFF) |
SFF front panel with bezel
Number | Item | Description |
1 | POWER LED |
Green: Drive tray is powered on. |
2 | READY LED |
Green: Drive tray is operational. |
3 | Locate LED |
Amber:
|
4 | Lock |
Locks and unlocks the front panel bezel by using the supplied key. |
SFF front panel without bezel
Number | Item | Description |
1 |
POWER, READY, and LOCATE LEDs |
Green: Drive tray is powered on. |
Green: Drive tray is operational. | ||
Amber:
| ||
2 |
ALM LED | Red: Drive stopped due to a failure and can be replaced. |
3 |
ACT LED |
Green: Normal operation. Blink green: Drive is being accessed. |
4 | Small-form-factor drives |
The twenty-four 2.5-inch SFF drives are positioned vertically. The slots are organized from 0 to 23. |
SFF rear panel
Number | Item | Description |
1 | PATH (IN) connector |
Connects to a controller or drive tray. |
2 | PATH (OUT) connector |
Connects to a drive tray. |
3 | ENC | N/A |
4 | PATH (IN) LED |
Blue: IN side port is linked up. |
5 | PATH (OUT) LED |
Blue: OUT side port is linked up. |
6 | Console |
These ports are reserved. |
7 | POWER LED |
Green: ENC is in the power-on state. |
8 | LOCATE LED |
Amber:
|
9 | ALARM LED | Red: ENC can be replaced. |
10 | Power supply unit | N/A |
11 | Receptacle |
Connects to the power cable provided with the storage system. |
12 | ALM LED |
Red: Power supply unit can be replaced. |
13 | AC IN LED |
Green: Normal operation. |
14 | RDY1 LED |
Green: Normal operation. |
15 | RDY2 LED |
Green: Normal operation. |
AC power supply unit LEDs and connectors
SFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display their operating status.
Number | Item | Description |
1 | RDY2 LED |
Green: Normal operation. |
2 | RDY1 LED |
Green: Normal operation. |
3 | Receptacle |
Connects to the power cable provided with the storage system. |
4 | AC IN LED |
Green: Normal operation. |
5 | ALM LED |
Red: Power supply unit can be replaced. |
Large-form-factor drive tray (DBL)
The following table describes the physical specifications of the large-form-factor (LFF) drive tray.
Name |
Model name |
Height |
Number of drive slots |
Drive type |
DBL |
DW-F1000-DBL |
2U (88.2 mm) |
12 |
3.5 inch (LFF) |
DBLE |
DW-F1000-DBLE |
2U (88.2 mm) |
12 |
3.5 inch (LFF) |
LFF front panel with bezel
Number | Item | Description |
1 | POWER LED |
Green: Drive tray is powered on. |
2 | READY LED |
Green: Drive tray is operational. |
3 | Locate LED |
Amber:
|
4 | Lock |
Locks and unlocks the front panel bezel by using the supplied key. |
LFF front panel without bezel
Number | Item | Description |
1 |
POWER, READY, and LOCATE LEDs |
Green: Drive tray is powered on. |
Green: Drive tray is operational. | ||
Amber:
| ||
2 | ACT LED |
Green: Normal operation. Blink green: Drive is being accessed. |
3 |
ALM LED | Red: Drive stopped due to a failure and can be replaced. |
4 | Large-form-factor drives |
The twelve 3.5-inch LFF drives are positioned horizontally. The slots are organized in the following order: 8 9 10 11 4 5 6 7 0 1 2 3 |
LFF rear panel
Number | Item | Description |
1 | ENC | N/A |
2 | POWER LED |
Green: ENC is in the power-on state. |
3 | Locate LED |
Amber:
|
4 | ALARM LED |
Red: ENC can be replaced. |
5 | PATH (IN) LED |
Blue: IN side port is linked up. |
6 | PATH (IN) connector |
Connects to a controller or drive tray. |
7 | PATH (OUT) LED |
Blue: OUT side port is linked up. |
8 | PATH (OUT) connector |
Connects to a drive tray. |
9 | Console |
This port is reserved. |
10 | Power supply unit | N/A |
11 | Receptacle |
Connects to the power cable provided with the storage system. |
12 | AC IN LED |
Green: Normal operation. |
13 | ALM LED |
Red: Power supply unit can be replaced. |
14 | RDY LED |
Green: Normal operation. |
AC power supply unit LEDs and connectors
Both SFF and LFF drive trays are equipped with AC power supply units. The AC power supply units include LEDs to display their operating status.
Number | Item | Description |
1 | RDY LED |
Green: Normal operation. |
2 | ACI IN LED |
Green: AC input is operating normally. |
3 | ALM LED |
Red: Power supply unit can be replaced. |
High-density intermix drive tray (DB60)
The following table describes the physical specifications of the high-density drive tray.
Name |
Model name |
Height |
Number of drive slots |
Drive type |
DB60 |
DW-F1000-DB60 |
4U (176 mm) |
60 |
3.5 inch (LFF) |
DB60E |
DW-F1000-DB60E |
4U (176 mm) |
60 |
3.5 inch (LFF) |
Dense intermix drive tray front panel with bezel
Number | Item | Description |
1 | POWER LED |
Green: Drive tray is powered on. |
2 | READY LED |
Green: Drive tray is operational. |
3 | Locate LED |
Amber:
|
4 | Lock |
Locks and unlocks the front panel bezel by using the supplied key. |
Dense intermix drive tray display LEDs
Number | Item | Description |
1 |
ACT |
Green: Normal operation. Blink: Drive is being accessed. |
2 | ALM LED |
Red: Drive stopped due to a failure and can be replaced. |
- Rear of drive tray: 48-59
- 36-47
- 24-35
- 12-23
- Front of drive tray: 00-11
Dense intermix drive tray rear panel
Number | Item | Description |
1 | Power supply unit | N/A |
2 | RDY LED |
Green: Normal operation. |
3 | AC IN LED |
Green: Normal operation. |
4 | ALM LED |
Red: Power supply unit can be replaced. |
5 | Receptacle |
Connects to the power cable provided with the storage system. |
6 | ENC | N/A |
7 | PATH (OUT) LED |
Blue: OUT side port is linked up. |
8 | PATH (OUT) connector |
Connects to a drive tray. |
9 | PATH (IN) LED |
Blue: IN side port is linked up. |
10 | PATH (IN) connector |
Connects to a controller or drive tray. |
11 | Console | This port is reserved. |
12 | ALARM LED |
Red: ENC can be replaced. |
13 | Locate LED |
Amber:
|
14 | POWER LED |
Green: ENC is in the power-on state. |
Host port expansion chassis
The host port expansion chassis contains various interconnect adapters that connect a host system to storage and other network devices. The interconnect adapters include PCIe boards and iSCSI and FC cards.
Host port expansion chassis front-panel bezel LEDs
Number | Item | Description |
1 | POWER LED | Green: Host port expansion is turned on. Amber: PCIe module is turned on. Off: PCIe module is turned off. |
2 | Safety lock | Lock or unlock the front bezel. |
PCIe switchboard
Number | Item | Description |
1 | STATUS LED | Green: PCIe switchboard is powered on.
Red: PCIe switchboard can be replaced safely. Off: PCIe switchboard is powered off. |
Host port expansion chassis fan
Number | Item | Description |
1 | ALM LED | Red: Fan failure has occurred.
Off: Normal operation. |
PCIe cable connector
Number | Item | Description |
1 | STATUS LED | Green: PCIe cable connector is powered on. Red: PCIe cable connector can be replaced safely. Off: PCIe cable connector is powered off. |
2 | Link Basic LED | Green: Basic PCIe Gen-3.0 (8-Gbps) is linked up normally. Off: Basic PCIe is not linked up (PCIe cable might not be connected). If a cable is connected, it can be removed safely. |
3 | InAct Basic LED | Amber: Basic PCIe status changed from link up to link down and cables. Cables can be removed safely. Off: Basic PCIe is normal or not set. |
4 | Link Option LED | Green: Option PCIe Gen-3.0 (8-Gbps) is linked up normally. Off: Option PCIe is not linked up (PCIe cable might not be connected). If a cable is connected, it can be removed safely. |
5 | InAct Option LED | Amber: Option PCIe status changed from link up to link down and cables. Cables can be removed safely. Off: Option PCIe is normal or not set. |
Host port expansion chassis power supply
Number | Item | Description |
1 | ALM / RDY LED | Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. |
2 | AC IN LED | Blue: AC input is normal. |
Rack support
The storage system can be installed in the Hitachi Universal V3 Rack, Universal V2B Rack, or Universal V2 Rack as well as non-Hitachi 19-inch racks that meet the storage system's specifications.
Non-Hitachi racks must be 4-post, EIA 310-D compliant with adequate airflow and weight capacity. The PDUs must be mounted properly to avoid any issues for servicing the storage system. The PDU receptacles must face toward the back (not toward each other). The area behind the storage system and between the vertical 19-inch mounting posts must be free of PDUs and cable loops.