Introduction
The Hitachi Virtual Storage Platform E590 (VSP E590) and Hitachi Virtual Storage Platform E790 (VSP E790) storage systems are high-performance, large-capacity data storage systems utilizing all-flash NVMe solid-state drives. The storage system consists of a controller chassis and internal components such as fans and PCIe switches.
The NVMe architecture delivers consistent, low-microsecond latency which reduces the transaction costs of latency-critical applications and delivers predictable performance to optimize storage resources.
Key features
- Multiple controller configuration distributes processing to each controller
- High-speed processing facilitated by up to 768 GiB of cache
- I/O processing speed increased by NVMe flash drives
- High-speed front-end data transfer up to 3.2 GB/s for FC and 1 GB/s for iSCSI
- Response times as low as 66 microseconds
- Integrated with Hitachi Ops Center to improve IT operational efficiencies
- Service continuity by main components in redundant configuration
- RAID 1, RAID 5, and RAID 6 support (RAID 6 including 14D+2P)
- Data security by transferring data to cache flash memory at the time of a power outage
- Scalable capacity up to .36 PB (internal), 144 PB (external), and 4M IOPS for VSP E590 .36 PB (internal), 216 PB (external), and 6.8M IOPS for VSP E790.
- Heterogeneous connectivity supporting concurrent attachment to a variety of hosts, including VMware, Linux, UNIX, and Windows
Storage system specifications
The storage system offers superior performance, resiliency, and agility, featuring response times as low as 64 microseconds, all backed up with the industry’s first and most comprehensive 100% data availability guarantee. The following table lists the key operational and performance specifications for the storage system.
Item |
Specification | |||
System |
Number of NVMe flash drives |
Minimum |
4 | |
Maximum |
24 | |||
RAID group configuration | RAID 6 |
| ||
RAID 5 |
| |||
RAID 1 |
| |||
Maximum number of spare drives |
8 | |||
Maximum number of volumes |
49,152 | |||
Maximum storage system capacity (physical capacity) |
15 TB 2.5-inch SSD used |
.33 PiB (.36 PB) | ||
Maximum external configuration |
192 PiB (216 PB) | |||
Memory |
Cache memory capacity |
768 GiB | ||
Storage interface |
DKC-drive interface |
NVMe/Dual Port | ||
Data transfer rate |
8 Gbps | |||
Device interface |
Supported channel types |
| ||
Data transfer rate |
Fibre Channel |
up to 4 GB/s | ||
iSCSI (Optical) |
10 Gbps | |||
Maximum number of front-end modules |
6 |
Item |
Specification | |||
System |
Number of NVMe flash drives |
Minimum |
4 | |
Maximum |
24 | |||
RAID group configuration | RAID 6 |
| ||
RAID 5 |
| |||
RAID 1 |
| |||
Maximum number of spare drives |
8 | |||
Maximum number of volumes |
32,768 | |||
Maximum storage system capacity (physical capacity) |
15 TB 2.5-inch SSD used |
.33 PiB (.36 PB) | ||
Maximum external configuration |
128 PiB (144 PB) | |||
Memory |
Cache memory capacity |
384 GiB to 768 GiB | ||
Storage interface |
DKC-drive interface |
NVMe/Dual Port | ||
Data transfer rate |
8 Gbps | |||
Device interface |
Supported channel types |
| ||
Data transfer rate |
Fibre Channel |
up to 4 GB/s | ||
iSCSI (Optical) |
10 Gbps | |||
Maximum number of front-end modules |
6 |