Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

Introduction

The Hitachi Virtual Storage Platform E590 (VSP E590) and Hitachi Virtual Storage Platform E790 (VSP E790) storage systems are high-performance, large-capacity data storage systems utilizing all-flash NVMe solid-state drives. The storage system consists of a controller chassis and internal components such as fans and PCIe switches.

The NVMe architecture delivers consistent, low-microsecond latency which reduces the transaction costs of latency-critical applications and delivers predictable performance to optimize storage resources.

Key features

High performance
  • Multiple controller configuration distributes processing to each controller
  • High-speed processing facilitated by up to 768 GiB of cache
  • I/O processing speed increased by NVMe flash drives
  • High-speed front-end data transfer up to 3.2 GB/s for FC and 1 GB/s for iSCSI
  • Response times as low as 66 microseconds
  • Integrated with Hitachi Ops Center to improve IT operational efficiencies
High reliability
  • Service continuity by main components in redundant configuration
  • RAID 1, RAID 5, and RAID 6 support (RAID 6 including 14D+2P)
  • Data security by transferring data to cache flash memory at the time of a power outage
Scalability and versatility
  • Scalable capacity up to .36 PB (internal), 144 PB (external), and 4M IOPS for VSP E590 .36 PB (internal), 216 PB (external), and 6.8M IOPS for VSP E790.
  • Heterogeneous connectivity supporting concurrent attachment to a variety of hosts, including VMware, Linux, UNIX, and Windows

Storage system specifications

The storage system offers superior performance, resiliency, and agility, featuring response times as low as 64 microseconds, all backed up with the industry’s first and most comprehensive 100% data availability guarantee. The following table lists the key operational and performance specifications for the storage system.

VSP E790 specifications

Item

Specification

System

Number of NVMe flash drives

Minimum

4

Maximum

24

RAID group configuration

RAID 6

  • 6D+2P
  • 12D+2P
  • 14D+2P
RAID 5

  • 3D+1P
  • 4D+1P
  • 6D+1P
  • 7D+1P
RAID 1

  • 2D+2D
  • 4D+4D

Maximum number of spare drives

8

Maximum number of volumes

49,152

Maximum storage system capacity (physical capacity)

15 TB 2.5-inch SSD used

.33 PiB (.36 PB)

Maximum external configuration

192 PiB (216 PB)

Memory

Cache memory capacity

768 GiB

Storage interface

DKC-drive interface

NVMe/Dual Port

Data transfer rate

8 Gbps

Device interface

Supported channel types

  • Fibre Channel (shortwave, longwave)
  • iSCSI (optical)

Data transfer rate

Fibre Channel

up to 4 GB/s

iSCSI (Optical)

10 Gbps

Maximum number of front-end modules

6

VSP E590 specifications

Item

Specification

System

Number of NVMe flash drives

Minimum

4

Maximum

24

RAID group configuration

RAID 6

  • 6D+2P
  • 12D+2P
  • 14D+2P
RAID 5

  • 3D+1P
  • 4D+1P
  • 6D+1P
  • 7D+1P
RAID 1

  • 2D+2D
  • 4D+4D

Maximum number of spare drives

8

Maximum number of volumes

32,768

Maximum storage system capacity (physical capacity)

15 TB 2.5-inch SSD used

.33 PiB (.36 PB)

Maximum external configuration

128 PiB (144 PB)

Memory

Cache memory capacity

384 GiB to 768 GiB

Storage interface

DKC-drive interface

NVMe/Dual Port

Data transfer rate

8 Gbps

Device interface

Supported channel types

  • Fibre Channel (shortwave, longwave)
  • iSCSI (optical)

Data transfer rate

Fibre Channel

up to 4 GB/s

iSCSI (Optical)

10 Gbps

Maximum number of front-end modules

6