VSP G400, G600 storage system specifications

The following table provides an overview of the system specifications for VSP G400, G600 storage systems.

Item VSP G400, G600 specifications
System VSP G600 VSP G400
Number of disk drives Minimum 4 (disk-in model) / 0 (diskless model) *10
Maximum 720 480
Number of flash drives Minimum 4 (disk-in model) / 0 (diskless model) *10
Maximum 720 480
Number of flash module drives Minimum 4
Maximum 288 192
RAID level RAID1, RAID5, RAID6
RAID group configuration RAID6 6D+2P, 12D+2P, 14D+2P
RAID5 3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID1 2D+2D, 4D+4D
Maximum number of spare drives 32 *1
Maximum number of LDEVs 4,096
Maximum storage system capacity (physical capacity) (SFF HDD/1.8 TB) 996 TB (SFF HDD/1.8 TB) 664 TB
(SSD/3.8 TB) 2,178 TB (SSD/3.8 TB) 1,452 TB
(LFF HDD/10 TB) 7,049 TB (LFF HDD/10 TB) 4,699 TB
(NF/14 TB) 4,053 TB (NF/14 TB) 2,702 TB
Maximum external configuration 16 PB
Memory Cache memory capacity 64 GB to 256 GB 64 GB/128 GB
Cache memory capacity with NAS module is installed9 256 GB 128 GB
Cache flash memory BM20/BM30
Storage I/F DKC to drive interface SAS/Dual Port
Data transfer rate 6Gbps/12Gbps
Maximum number of HDD per SAS I/F 144
Maximum number of DKB PCB 2
Device I/F Support channel Type Open system Fibre Channel Short Wavelength *2 / iSCSI*4
NAS (NFS/CIFS)
Data transfer rate Fibre Channel 200/400/800/1,600/3,200 MB/s
iSCSI 100/1,000 MB/s
NAS(NFS/CIFS) 1,000 MB/s
Maximum number of CHB 8 (10:DKB Slot used)
14*8 (16:DKB Slot used)
Maximum number of CHB with NAS module is installed 6
Power AC input Single phase 50Hz/60Hz : 200V to 240V
DC input*7 N/A
Acoustic level*3 Operating CBL 60dB
CBSS/CBSL N/A
DBS/DBSC/DBL/DBLC/DBF 60dB
DBSD/DBLD N/A
DB60/DB60C 71dB(*5 *6)
Standby CBL 55dB
CBSS/CBSL N/A
DBS/DBSC/DBL/DBLC/DBF 55dB
DBSD/DBLD N/A
DB60/DB60C 71dB(*5 *6)
Non-stop maintenance Control PCB Supported
Cache memory Supported
Cache flash memory Supported
Power supply, fan Supported
Microcode Supported
Disk drive, flash drive, flash module drive Supported

Notes:

*1: Available as spare or data disks.

*2: By the replacing SFP transceiver of the fibre port on the CHB to the DKC-F810I-1PL8/1PL16, the port can be used for the long wavelength.

*3: Measurement Condition: The point 1m far from floor and surface of the product.

*4: Short Wavelength model is DW-F800-2HS10S, Copper model is DW-F800-2HS10B.

*5: Sound pressure level [LA] changes from 66dB to 75dB according to the ambient temperature, drive configuration and operating status. The maximum could be 79dB during maintenance procedure for failed ENC or Power Supply.

*6: Acoustic power level [LwA] measured by ISO7779 condition is 7.2B. And it changes from 7.2B to 8.1B according to the ambient temperature, drive configuration and operating status.

*7: The DC power supply is unavailable.

*8: SVOS6.3.1 or later

*9: The capacity of the cache memory installed in RAID controller. A cache memory installed in NAS module is not included.

*10: When NAS Module is installed, the Diskless configuration is not supported