VSP G400, G600 storage system specifications
The following table provides an overview of the system specifications for VSP G400, G600 storage systems.
Item | VSP G400, G600 specifications | |||
System | VSP G600 | VSP G400 | ||
Number of disk drives | Minimum | 4 (disk-in model) / 0 (diskless model) *10 | ||
Maximum | 720 | 480 | ||
Number of flash drives | Minimum | 4 (disk-in model) / 0 (diskless model) *10 | ||
Maximum | 720 | 480 | ||
Number of flash module drives | Minimum | 4 | ||
Maximum | 288 | 192 | ||
RAID level | RAID1, RAID5, RAID6 | |||
RAID group configuration | RAID6 | 6D+2P, 12D+2P, 14D+2P | ||
RAID5 | 3D+1P, 4D+1P, 6D+1P, 7D+1P | |||
RAID1 | 2D+2D, 4D+4D | |||
Maximum number of spare drives | 32 *1 | |||
Maximum number of LDEVs | 4,096 | |||
Maximum storage system capacity (physical capacity) | (SFF HDD/1.8 TB) 996 TB | (SFF HDD/1.8 TB) 664 TB | ||
(SSD/3.8 TB) 2,178 TB | (SSD/3.8 TB) 1,452 TB | |||
(LFF HDD/10 TB) 7,049 TB | (LFF HDD/10 TB) 4,699 TB | |||
(NF/14 TB) 4,053 TB | (NF/14 TB) 2,702 TB | |||
Maximum external configuration | 16 PB | |||
Memory | Cache memory capacity | 64 GB to 256 GB | 64 GB/128 GB | |
Cache memory capacity with NAS module is installed9 | 256 GB | 128 GB | ||
Cache flash memory | BM20/BM30 | |||
Storage I/F | DKC to drive interface | SAS/Dual Port | ||
Data transfer rate | 6Gbps/12Gbps | |||
Maximum number of HDD per SAS I/F | 144 | |||
Maximum number of DKB PCB | 2 | |||
Device I/F | Support channel Type | Open system | Fibre Channel Short Wavelength *2 / iSCSI*4 | |
NAS (NFS/CIFS) | ||||
Data transfer rate | Fibre Channel | 200/400/800/1,600/3,200 MB/s | ||
iSCSI | 100/1,000 MB/s | |||
NAS(NFS/CIFS) | 1,000 MB/s | |||
Maximum number of CHB | 8 (10:DKB Slot used) | |||
14*8 (16:DKB Slot used) | ||||
Maximum number of CHB with NAS module is installed | 6 | |||
Power | AC input | Single phase | 50Hz/60Hz : 200V to 240V | |
DC input*7 | N/A | |||
Acoustic level*3 | Operating | CBL | 60dB | |
CBSS/CBSL | N/A | |||
DBS/DBSC/DBL/DBLC/DBF | 60dB | |||
DBSD/DBLD | N/A | |||
DB60/DB60C | 71dB(*5 *6) | |||
Standby | CBL | 55dB | ||
CBSS/CBSL | N/A | |||
DBS/DBSC/DBL/DBLC/DBF | 55dB | |||
DBSD/DBLD | N/A | |||
DB60/DB60C | 71dB(*5 *6) | |||
Non-stop maintenance | Control PCB | Supported | ||
Cache memory | Supported | |||
Cache flash memory | Supported | |||
Power supply, fan | Supported | |||
Microcode | Supported | |||
Disk drive, flash drive, flash module drive | Supported | |||
Notes: *1: Available as spare or data disks. *2: By the replacing SFP transceiver of the fibre port on the CHB to the DKC-F810I-1PL8/1PL16, the port can be used for the long wavelength. *3: Measurement Condition: The point 1m far from floor and surface of the product. *4: Short Wavelength model is DW-F800-2HS10S, Copper model is DW-F800-2HS10B. *5: Sound pressure level [LA] changes from 66dB to 75dB according to the ambient temperature, drive configuration and operating status. The maximum could be 79dB during maintenance procedure for failed ENC or Power Supply. *6: Acoustic power level [LwA] measured by ISO7779 condition is 7.2B. And it changes from 7.2B to 8.1B according to the ambient temperature, drive configuration and operating status. *7: The DC power supply is unavailable. *8: SVOS6.3.1 or later *9: The capacity of the cache memory installed in RAID controller. A cache memory installed in NAS module is not included. *10: When NAS Module is installed, the Diskless configuration is not supported |