Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

VSP G200 storage system components

The VSP G200 includes essential building blocks such as controllers, drive trays, and other optional front and back end components.

Model lists

Hitachi Virtual Storage Platform G200 controller model list

CBSS controller components

Part number

Part name

Quantity

DW800-CBSS 2U chassis 1
AC power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Backup module (BKM) 2
Front bezel (2U) 1
Binder 1
SAS cable label 2
Controller 2
DW-F800-BM10 Cache flash memory 2
CBSS controller optional components

Part number

Part name

Quantity

DW-F800-CTLS Controller Board 2
DW-F800-CTLSE Controller Board (Encryption) 2
DW-F800-2HS10S Front end module (10-Gbps SFP iSCSI optical) 2-4
DW-F800-2HS10B Front end module (10-Gbps SFP iSCSI copper) 2-4
DW-F800-4HF8 Front end module (8-Gbps 4-port FC) 2-4
DW-F800-2HF16 Front end module (16-Gbps 2-port FC) 2-4
DW-F800-4HF32R Front end module (32-Gbps, 16-Gbps 4-port FC) 2-4
DKC-F810I-CM8G Cache memory (8 GB) 4
DKC-F810I-CM16G Cache memory (16 GB) 4
DW-F800-BM10 Cache Flash Memory (CFM) 2
DKC-F810I-200MEM1 200 GB, 2.5-inch, MLC, SSD 0-24
DKC-F810I-300KCM1 300 GB, 2.5-inch, 15k, SAS, HDD (contains BNST) 0-24
DKC-F810I-300KCMC1 300 GB, 2.5-inch,15k, SAS, HDD 0-24
DKC-F810I-400MEM 1 400 GB, 2.5-inch, MLC, SAS, SSD 0-24
DKC-F810I-480MGM1 480 GB, 2.5-inch, MLC, SAS, SSD 0-24
DKC-F810I-600JCM1 600 GB, 2.5-inch, 10k, SAS, HDD (contains BNST) 0-24
DKC-F810I-600JCMC1 600 GB, 2.5-inch, 10k, SAS, HDD 0-24
DKC-F810I-600KGM1 600 GB, 2.5-inch, 15k, SAS, HDD 0-24
DKC-F810I-960MGM 960 GB, 2.5-inch, MLC, SAS, SSD 0-24
DKC-F810I-1R2JCM 1.2 TB, 2.5-inch, 10k, SAS, HDD (contains BNST) 0-24
DKC-F810I-1R2JCMC 1.2 TB, 2.5-inch, 10k, SAS, HDD 0-24
DKC-F810I-1R8JGM 1.8 TB, 2.5-inch, 10k, SAS, HDD 0-24
DKC-F810I-1R9MEM 1.9 TB, 2.5-inch, MLC, SAS, SSD 0-24
DKC-F810I-3R8MGM 3.8 TB, 2.5-inch, MLC, SAS, SSD 0-24
DKC-F810I-6R4FN 7 TB (6.4 TiB), 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-14RFP 14 TB, 12-Gbps SAS, Flash Module Drive DC2 0-12
DW-F800-1PS8 SFP for 8-Gbps shortwave 0-16
DW-F800-1PL8 SFP for 8-Gbps longwave 0-16
DW-F800-1PS16 SFP for 16-Gbps shortwave 0-16
DW-F800-1PL16 SFP for 16-Gbps longwave 0-16
DKC-F810I-1PS32 SFP for 32-Gbps shortwave 0-16

Notes:

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

CBSSD controller components

Part number

Part name

Quantity

DW800-CBSSD 2U chassis 1
DC power supply unit 2
Power cable (1.5 m) 2
Power cable (3 m) 2
Backup module (BKM) 2
Front bezel (2U) 1
Air filter 1
Binder 1
SAS cable label 2
Controller 2
DW-F800-BM10 Cache flash memory 2
CBSSD controller optional components

Part number

Part name

Quantity

DW-F800-CTLS Controller Board 2
DW-F800-CTLSE Controller Board (Encryption) 2
DW-F800-2HS10S Front end module (10-Gbps SFP iSCSI optical) 2-4
DW-F800-2HS10B Front end module (10-Gbps SFP iSCSI copper) 2-4
DW-F800-4HF8 Front end module (8-Gbps 4-port FC) 2-4
DW-F800-2HF16 Front end module (16-Gbps 2-port FC) 2-4
DW-F800-4HF32R Front end module (32-Gbps, 16-Gbps 4-port FC) 2-4
DKC-F810I-CM8G Cache memory (8 GB) 4
DKC-F810I-CM16G Cache memory (16 GB) 4
DW-F800-BM10 Cache Flash Memory (CFM) 2
DKC-F810I-200MEM1 200 GB, 2.5-inch, MLC, 12-Gbps, SSD 0-24
DKC-F810I-300KCM1 300 GB, 2.5-inch, 15k, 6-Gbps, SAS, HDD (contains BNST) 0-24
DKC-F810I-300KCMC1 300 GB, 2.5-inch,15k, 6-Gbps, SAS, HDD 0-24
DKC-F810I-400MEM1 400 GB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-24
DKC-F810I-480MGM1 480 GB, 2.5-inch, MLC, 12 Gbps, SAS, SSD 0-24
DKC-F810I-600JCM1 600 GB, 2.5-inch, 10k, 6-Gbps, SAS, HDD (contains BNST) 0-24
DKC-F810I-600JCMC1 600 GB, 2.5-inch, 10k, 6-Gbps, SAS, HDD 0-24
DKC-F810I-600KGM1 600 GB, 2.5-inch, 15k, 12-Gbps, SAS, HDD 0-24
DKC-F810I-960MGM 960 GB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-24
DKC-F810I-1R2JCM 1.2 TB, 2.5-inch, 10k, 6-Gbps, SAS, HDD (contains BNST) 0-24
DKC-F810I-1R2JCMC 1.2 TB, 2.5-inch, 10k, 6-Gbps, SAS, HDD 0-24
DKC-F810I-1R8JGM 1.8 TB, 2.5-inch, 10k, 6-Gbps, SAS, HDD 0-24
DKC-F810I-1R6FN 1.6 TB, 12-Gbps SAS, Flash Module Drive DC2 0-24
DKC-F810I-1R9MEM 1.9 TB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-24
DKC-F810I-3R2FN 3.2 TB, 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-3R8MGM 3.8 TB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-12
DKC-F810I-6R4FN 7 TB (6.4 TiB), 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-14RFP 14 TB, 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-1PS8 SFP for 8-Gbps shortwave 0-16
DKC-F810I-1PL8 SFP for 8-Gbps longwave 0-16
DKC-F810I-1PS16 SFP for 16-Gbps shortwave 0-16
DKC-F810I-1PL16 SFP for 16-Gbps longwave 0-16
DKC-F810I-1PS32 SFP for 32-Gbps shortwave 0-16

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

CBSL controller components

Part number

Part name

Quantity

DW800-CBSL 2U chassis 1
AC power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Backup module 2
Front bezel (2U) 1
Binder 1
SAS cable label 2
Controller 2
DW-F800-BM10 Cache flash memory 2
CBSL controller optional components

Part number

Part name

Quantity

DW-F800-CTLS Controller Board 2
DW-F800-CTLSE Controller Board (Encryption) 2
DW-F800-2HS10S Front end module (10-Gbps SFP iSCSI optical) 2-4
DW-F800-2HS10B Front end module (10-Gbps SFP iSCSI copper) 2-4
DW-F800-4HF8 Front end module (8-Gbps 4-port FC) 2-4
DW-F800-2HF16 Front end module (16-Gbps 2-port FC) 2-4
DW-F800-4HF32R Front end module (32-Gbps, 16-Gbps 4-port FC) 2-4
DKC-F810I-CM8G Cache memory (8 GB) 4
DKC-F810I-CM16G Cache memory (16 GB) 4
DW-F800-BM10 Cache Flash Memory (CFM) 2
DKC-F810I-400M6M1 400 GB, LFF SSD 0-12
DKC-F810I-1R2J5M1 1.2 TB, 3.5-inch, 10k, SAS HDD (contains BNST) 0-12
DKC-F810I-1R2J5MC1 1.2 TB, SAS, LFF HDD 0-12
DKC-F810I-1R8J61 1 1.8 TB, 3.5-inch, 10k, SAS, HDD 0-12
DKC-F810I-4R0H3M1 4 TB, 7.2K 3.5-inch, SAS, HDD (contains BNST) 0-12
DKC-F810I-4R0H3MC1 4 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-4R0H4M1 4 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-6R0H9M1 6 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-10RH9M 10 TB 7.2K, 3.5-inch, SAS, HDD 0-12
DKC-F810I-6R4FN 7 TB (6.4 TiB), 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-14RFP 14 TB, 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-1PS8 SFP for 8-Gbps shortwave 0-16
DKC-F810I-1PL8 SFP for 8-Gbps longwave 0-16
DKC-F810I-1PS16 SFP for 16-Gbps shortwave 0-16
DKC-F810I-1PL16 SFP for 16-Gbps longwave 0-16
DKC-F810I-1PS32 SFP for 32-Gbps shortwave 0-16

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

CBSLD controller components

Part number

Part name

Quantity

DW800-CBSLD 2U chassis 1
DC power supply unit 2
Power cable (1.5 m) 2
Power cable (3 m) 2
Backup module 2
Front bezel (2U) 1
Binder 1
Air filter 1
SAS cable label 2
Controller 2
DW-F800-BM10 Cache flash memory 2
CBSLD controller optional components

Part number

Part name

Quantity

DW-F800-CTLS Controller Board 2
DW-F800-CTLSE Controller Board (Encryption) 2
DW-F800-2HS10S Front end module (10-Gbps SFP iSCSI optical) 2-4
DW-F800-2HS10B Front end module (10-Gbps SFP iSCSI copper) 2-4
DW-F800-4HF8 Front end module (8-Gbps 4-port FC) 2-4
DW-F800-2HF16 Front end module (16-Gbps 2-port FC) 2-4
DW-F800-4HF32R Front end module (32-Gbps, 16-Gbps 4-port FC) 2-4
DKC-F810I-CM8G Cache memory (8 GB) 4
DKC-F810I-CM16G Cache memory (16 GB) 4
DW-F800-BM10 Cache Flash Memory (CFM) 2
DKC-F810I-400M6M1 400 GB, 3.5-inch, flash drive 0-12
DKC-F810I-1R2J5M1 1.2 TB, 3.5-inch, 10k, SAS, HDD (contains BNST) 0-12
DKC-F810I-1R8J6M1 1.8 TB, 3.5-inch, 10k, SAS, HDD 0-12
DKC-F810I-4R0H3M1 4 TB, 7.2K 3.5-inch, SAS, HDD (contains BNST) 0-12
DKC-F810I-4R0H4M1 4 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-4R0H3MC 1 4 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-6R0H9M1 6 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-6R0HLM 6 TB, 7.2K 3.5-inch, SAS, HDD 0-12
DKC-F810I-10RH9M 10 TB 7.2K, 3.5-inch, SAS, HDD 0-12
DKC-F810I-6R4FN 7 TB (6.4 TiB), 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-14RFP 14 TB, 12-Gbps SAS, Flash Module Drive DC2 0-12
DKC-F810I-1PS8 SFP for 8-Gbps shortwave 0-16
DKC-F810I-1PL8 SFP for 8-Gbps longwave 0-16
DKC-F810I-1PS16 SFP for 16-Gbps shortwave 0-16
DKC-F810I-1PL16 SFP for 16-Gbps longwave 0-16
DKC-F810I-1PS32 SFP for 32-Gbps shortwave 0-16

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

Drive tray model lists

SFF drive tray components (AC power)

Model number

Part name

Quantity

DW-F800-DBS and DW-F800-DBSC 2U chassis 1
ENC 2
AC power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Front bezel (2U) 1
SFF drive tray components (DC power)

Model number

Part name

Quantity

DW-F800-DBSD 2U chassis 1
ENC 2
DC power supply unit 2
Power cable (1.5 m) 2
Power cable (3 m) 2
Front bezel (2U) 1
Air filter 1
SFF drive tray optional components

Model number

Part name

Quantity

DKC-F810I-200MEM1 200 GB, MLC, 12-Gbps, SFF, SSD 0-24
DKC-F810I-300KCM1 300 GB, 15k, 6-Gbps, SAS, SFF, drive (contains BNST) 0-24
DKC-F810I-400MEM1 400 GB, MLC, 12-Gbps, SAS, SFF, SSD 0-24
DKC-F810I-480MGM1 480 GB, MLC, 12-Gbps, SAS, SFF, SSD 0-24
DKC-F810I-960MGM 1 960 GB, MLC, 12-Gbps, SAS, SFF, SSD 0-24
DKC-F810I-600JCM1 600 GB, 10kmin, 6-Gbps, SAS, SFF, drive (contains BNST) 0-24
DKC-F810I-600KGM1 600 GB, 15kmin, 6-Gbps, SAS, SFF, drive 0-24
DKC-F810I-1R2JCM1 1.2 TB, 10kmin, 6-Gbps, SAS, SFF, drive (contains BNST) 0-24
DKC-F810I-1R9MEM1 1.9 TB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-24
DKC-F810I-3R8MGM 1 3.8 TB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-24

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

LFF drive tray components (AC power)

Model number

Part name

Quantity

DW-F800-DBL and DW-F800-DBLC 2U chassis 1
ENC 2
AC power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Front bezel (2U) 1
LFF drive tray components (DC power)

Model number

Part name

Quantity

DW-F800-DBLD 2U chassis 1
ENC 2
DC power supply unit 2
Power cable (1.5 m) 2
Power cable (3 m) 2
Front bezel (2U) 1
Air filter 1
Optional LFF drive tray components

Model number

Part name

Quantity

DKC-F810I-400M6M1 400 GB, LFF, Flash drive 0-12
DKC-F810I-1R2J5MC1 1.2 TB, SAS, LFF, drive 0-12
DKC-F810I-1R8J6M1 1.8 TB, 10k, 6-Gbps, SAS, LFF, drive 0-12
DKC-F810I-4R0H3M1 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive (contains BNST) 0-12
DKC-F810I-6R0H9M1 6 TB, 7.2K, 12-Gbps, SAS, LFF, drive 0-12
DKC-F810I-10RH9M 10 TB, 7.2K, 12-Gbps, SAS, LFF, drive 0-12

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

FMD tray components

Model number

Part name

Quantity

DW-F800-DBF

2U chassis 1
ENC 2
Power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Front bezel (2U) 1
FMD tray optional components

Model number

Part name

Quantity

DKC-F710I-1R6FM1 1.75 TB, MLC, 6-Gbps, Flash Module Drive 0-12
DKC-F710I-3R2FM1 3.5, TB, MLC, 6-Gbps, Flash Module Drive 0-12
DKC-F810I-1R6FN1 1.75 TB, Flash Module Drive 0-12
DKC-F810I-3R2FN1 3.5 TB, Flash Module Drive 0-12
DKC-F810I-6R4FN1 7 TB, Flash Module Drive 0-12
DKC-F810I-7R0FP1 7 TB, MLC, 12-Gbps, Flash Module Drive 0-12
DKC-F810I-14RFP1 14 TB, MLC, 12-Gbps, Flash Module Drive 0-12

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

Dense intermix drive tray components

Model number

Part name

Quantity

DW-F800-DB60 and DW-F800-DB60C 4U box 1
ENC 2
Power supply unit 2
Power cable (0.9 m) 2
Power cable (2.5 m) 2
Front bezel (dense intermix drive tray) 1
DW-F800-SCQ3 SAS cable (3 m), including 2 omega clips

(DW-F800-SCQ3)

2
Dense intermix drive tray optional components (VSP Gx00 models only)

Model number

Part name

Quantity

DKC-F810I-400M8M1 400 GB, MLC, 12-Gbps, flash drive 0-60
DKC-F810I-1R2J7M1 1.2 TB, 10k, 6-Gbps, SAS, SFF, drive (contains BNST) 0-60
DKC-F810I-1R2J7MC1 1.2 TB, 10k, 6-Gbps, SAS, SFF, drive 0-60
DKC-F810I-1R8J8M1 1.8 TB, 10k, 6-Gbps, SAS, LFF drive 0-60
DKC-F810I-3R8MGM 1 3.8 TB, 2.5-inch, MLC, 12-Gbps, SAS, SSD 0-60
DKC-F810I-4R0H4M1 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive (contains BNST) 0-60
DKC-F810I-4R0H4MC1 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive 0-60
DKC-F810I-6R0HLM1 6 TB, 7.2K, 12-Gbps, SAS, LFF, drive 0-60
DKC-F810I-10RHLM1 10 TB, 7.2K, 12-Gbps, SAS, LFF, drive 0-60

1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes.

Cable model list

Numbers in parentheses show the quantities of the components.

Power cables

Model number

Specification

DW-F800-J1K 2.5 m, 2-pole power cable with grounding terminal (AC 125 V, 13 A or 15 A)
DW-F800-J2H 2.5 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A)
DW-F800-J2H5 5.0 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A)
DW-F800-J2H10 10.0 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A)
A-F6516-P620 Power cable for PDU (1)
A-F6516-P630 Power cable for PDU (1)
SAS cables

Model number

Specification

DW-F800-SCQ1 1 m SAS cable, including omega clips (2)
DW-F800-SCQ1F 1.5 m SAS cable, including omega clips (2)
DW-F800-SCQ3 3 m SAS cable, including omega clips (2)
DW-F800-SCQ5 5 m SAS cable, including omega clips (2)
DW-F800-SCQ10A 10 m SAS optical cable
DW-F800-SCQ30A 30 m SAS optical cable
DW-F800-SCQ1HA 100 m SAS optical cable
Optical cables

Model number

Specification

A-6515-GM5L 5 m LC-LC optical cable for optical
A-6515-GM10L 10 m LC-LC optical cable for optical
A-6515-GM20L 20 m LC-LC optical cable for optical
A-6515-GM30L 30 m LC-LC optical cable for optical
A-6515-GM40L 40 m LC-LC optical cable for optical
A-6515-GM50L 50 m LC-LC optical cable for optical
A-6515-GM1JL 100 m LC-LC optical cable for optical
A-6515-GS10L 10 m LC-LC optical cable for optical
A-6515-GS20L 20 m LC-LC optical cable for optical
A-6515-GS30L 30 m LC-LC optical cable for optical
A-6515-GS50L 50 m LC-LC optical cable for optical
A-6515-GS1JL 100 m LC-LC optical cable for optical
A-6515-HM5L 5 m LC-LC optical cable for optical
A-6515-HM10L 10 m LC-LC optical cable for optical
A-6515-HM20L 20 m LC-LC optical cable for optical
A-6515-HM30L 30 m LC-LC optical cable for optical
A-6515-HM50L 50 m LC-LC optical cable for optical
A-6515-HM100L 100 m LC-LC optical cable for optical
A-6515-HM200L 200 m LC-LC optical cable for optical
A-6515-HM300L 300 m LC-LC optical cable for optical
A-6515-JM5L 5 m LC-LC optical cable for optical
A-6515-JM10L 10 m LC-LC optical cable for optical
A-6515-JM20L 20 m LC-LC optical cable for optical
A-6515-JM30L 30 m LC-LC optical cable for optical
A-6515-JM50L 50 m LC-LC optical cable for optical
A-6515-JM100L 100 m LC-LC optical cable for optical
A-6515-JM200L 200 m LC-LC optical cable for optical
A-6515-JM300L 300 m LC-LC optical cable for optical

Battery specifications

The following table shows the lifetime expectancy of the batteries installed in the storage system.

Storage system intake temperature CBSS CBSL

Up to 75.2º F (24º C)

5 years 5 years

Up to 86º F (30º C)

5 years 4 years

Up to 93.2º (34º C)

4 years 3 years

Up to 104º (40º C)

3 years 2 years

RAID specifications

Item

SFF, LFF, dense intermix drive trays (range for setup)

RAID level

VSP G200: SAS, SAS 7.2k, flash drives mounted: 1, 5, 6

RAID configuration (unit of addition) RAID 1 2D+2D, 4D+4D
RAID 5 3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID 6 6D+2P, 12D+2P, 14D+2P
NoteAlthough certain RAID configurations support redundancy in the event of a drive failure, best practices dictate that you back up data on a regular basis.