The Hitachi Virtual Storage Platform F800 is a modular, rack-mountable all-flash array storage system, with various fixed storage capacity configurations of FMD DC2 flash storage devices. To deliver consistent low latency host response times and highest IOP performance across all host connection ports, no hard-disk drives are included.

The storage systems contain dual controllers for communicating with a data host. Each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. Each controller also has an Ethernet connection for out-of-band management. If the data path through one controller fails, all hard drives remain available to data hosts using a redundant data path through the other controller. The storage system controllers are replaceable.

The storage system can be equipped with network-attached storage (NAS) modules. The NAS modules provide file access through CIFS and NFS protocols and block access by using iSCSI protocols, in addition to the block access provided directly by iSCSI and Fibre Channel I/O modules.

All storage system models allow defective drives to be replaced without the interruption of data availability to host computers. A hot spare drive can be configured to replace a failed drive automatically, securing the fault-tolerant integrity of the logical drive. Self-contained, hardware-based RAID logical drives provide maximum performance in compact external enclosures.

Key components are implemented with a redundant configuration, so that the storage system can remain operational in the unlikely event that a component should fail. Adding and replacing components, along with firmware upgrades, can be conducted while the storage system is active.

Block configuration

 

A block-level storage provides the ability to access and provision raw storage volumes using protocols such as Fibre Channel and iSCSI.

A block configuration consists of the following:

  • Two controllers
  • One or more drive trays
  • One 1U block service processor server (SVP)

Unified configuration

 

A unified configuration includes NAS modules that support file system protocols such as CIFS and NFS operate across a block-level setup using iSCSI or FC connections.

  • Two controllers
  • Two NAS modules for file operations and storage
  • One or more drive trays for block-level storage
  • One 1U block service processor server (SVP)

VSP F800 model

 

The VSP F800 is a highly reliable all-flash system that offers high storage capacity with full redundancy to better protect data and manage storage operations.

The storage system consists of a 4U enclosure that includes two controllers, but without disk drives. Drives are supported using drive trays connected to the controllers.

Controller

Controller chassis

Controller model

Height

CBLH DW800-CBL DW‑F800‑CTLH 4U (174.3 mm)

Drive tray

Drive tray model name

Supported drive type

Number of drives supported

Height

FMD tray DW-F800-DBF 5.25-inch FMD 12 2U (86.2 mm)

High-speed memory cache

The storage system supports 512 GB of high-speed memory cache, arranged as 128 GB per controller.

FMD DC2 and FMD HD drives

The maximum number of FMD DC2 and FMD HD drives supported is 576, with a total raw flash capacity of 8,106 TB.

Pcode

Drive size

Raw capacity

DKC-F810I-1R6FN 1.75 TB 1759.21 GB
DKC-F810I-3R2FN 3.5 TB 3518.43 GB
DKC-F810I-6R4FN 7 TB 7036.87 GB
DKC-F810I-7R0FP 7 TB 7036.87 GB
DKC-F810I-14RFP 14 TB 14,073.74 GB

Interface ports

Interface ports are provided on front end modules. The system supports 24 front end modules.

Pcode

Description

Maximum number of ports supported
DW-F800-2HS10S 10-Gbps iSCSI (optical) front end module 24
DW-F800-2HS10B 10-Gbps iSCSI (copper) front end module 24
DW-F800-4HF8 8-Gbps Fibre Channel (4-port) front end module 48
DW-F800-2HF16 16-Gbps Fibre Channel (2-port) front end module 24
DW-F800-4HF32R 32/16-Gbps Fibre Channel (4-port) front end module 48

Features

 

The features described in the table are included with VSP F800

Feature

Value

Maximum cache memory supported 512 GB
Maximum number of spare drives 8

Maximum number of RAID groups

480

Maximum volume size

3 TB (4 TB when using the LDEVs of other Storage Systems)

Maximum number of volumes per host groups

2,048

Maximum number of volumes per RAID group

2,048

Maximum number of DP pool volumes

4,096

Maximum number of DP pools

64

Maximum number of iSCSI hosts connected through a network switch

255

Maximum number of Fibre Channel devices connected through a Fibre Channel switch

255

Scalability

 

All storage systems offer pay-as-you-grow scalability by allowing you to hot-add drives as you need them.

Examples of supported VSP F800 configurations

 

Drive tray

Maximum number of drive trays supported

Maximum number of drives supported

FMD2 drive tray 48 48 DC2 flash module drives

Supported all-flash array configurations

 

The following table lists the supported number of drive trays and drives in an all-flash array configuration.

 

Maximum number of drive trays supported Maximum number of drives supported
FMD FMD2 FMD FMD2
4 N/A 48 N/A
2 N/A 24 N/A
1 N/A 12 N/A
N/A 4 N/A 48
N/A 2 N/A 24
N/A 1 N/A 12

Maximum number of mounted drive trays

 

The following table lists the maximum number of mountable drive trays and mountable drives for each drive type.

 

VSP F800 Controller

Drive trays

Maximum number of trays

Maximum number of drives

CBLH

SFF

48

1152 HDDs or SSDs

LFF

48

576 HDDs or SSDs

FMD

48

576 FMDs (HAF)

FMD

4

40 FMDs + 2 spares (DC2)

48 FMDs