SIM codes
You can use the failure trap reference to identify trap reference codes (SIM codes) to see what section it affects and the alert levels.
Failure trap reference codes
The following table lists and describes the failure trap reference codes.
For details on alert levels, see the System Administrator Guide.
Trap reference code | Section | Description | Alert level | Host report1 | ||
SIM 22 | SIM 23 | SIM 13 | ||||
18 |
00 |
00 |
AuditLog lost |
DKC environment |
MODERATE |
Yes |
21 |
20 |
xx |
Channel port blocking |
Processor |
MODERATE |
Yes |
21 |
30 |
xx |
CHB blocking |
Environmental error |
MODERATE | Yes |
21 |
60 |
xx |
HIE blocking |
Cache |
MODERATE |
Yes |
21 |
61 |
xx |
ISW blocking |
Cache |
MODERATE |
Yes |
21 |
62 |
xx |
X path blocking |
Cache |
MODERATE |
Yes |
21 |
63 |
xx |
HIE warning |
Cache |
MODERATE |
Yes |
21 |
64 |
xx |
X path warning |
Cache |
MODERATE |
Yes |
21 |
80 |
xx |
Logical path(s) on the remote copy connections was logically blocked (Due to an error condition) |
Processor |
MODERATE |
Yes2 |
21 |
81 |
xx |
RIO PATH AUTOMATICALLY RECOVERED |
Processor |
SERVICE |
No |
21 |
90 |
xx |
AL_PA VALUE CONFLICT |
Processor |
SERVICE |
No |
21 |
93 |
xx |
LINK FAILURE |
Processor |
SERIOUS |
Yes |
21 |
94 |
xx |
LINK FAILURE2 |
Processor |
SERIOUS |
Yes |
21 |
a3 |
xx |
HTP blocking |
Processor |
MODERATE |
Yes |
21 |
a8 |
xx |
SFP wrong type |
Processor |
MODERATE |
No |
21 |
aa |
xx |
SFP TxFault |
Processor |
MODERATE |
No |
21 |
bx |
xx |
HTP hard error |
Processor |
MODERATE |
Yes |
21 |
d0 |
xx |
External storage system connection path blocking |
Processor |
MODERATE |
Yes |
21 |
d1 |
xx |
External storage system connection path restore |
Processor |
SERVICE |
No |
21 |
d2 |
xx |
Threshold over by external storage system connection path response time-out |
Processor |
SERVICE |
Yes |
21 |
d4 |
xx |
Blocking the Data Migration path |
Processor |
MODERATE |
No |
21 |
d5 |
xx |
Data Migration Path Recovery |
Processor |
SERVICE |
No |
30 |
70 |
xx |
CHK1A THRESHOLD OVER |
Processor |
SERVICE |
No |
30 |
71 |
xx |
CHK1B THRESHOLD OVER |
Processor |
SERVICE |
No |
30 |
72 |
xx |
CHK3 THRESHOLD OVER |
Processor |
SERVICE |
No |
30 |
73 |
xx |
PROCESSOR BLOCKING |
Processor |
MODERATE |
Yes |
30 |
75 |
xx |
FM ERROR |
Processor |
MODERATE |
Yes |
30 |
76 |
xx |
Incorrect SUM value of FM |
Processor |
SERVICE |
No |
30 |
77 |
xx |
PROCESSOR MEMORY TEMPORARY ERROR |
Processor |
SERVICE |
No |
30 |
78 | xx |
BFM error |
Processor |
SERIOUS |
Yes |
30 |
80 |
xx |
WCHK1 dump |
Processor |
MODERATE |
No |
30 |
a1 |
00 |
DKC Blockade |
Processor |
ACUTE |
Yes |
38 |
8f |
00 |
P/S OFF IMPOSSIBLE |
PS(DKC) |
MODERATE |
No |
38 |
9f |
00 |
P/S OFF IMPOSSIBLE(DEVICE RESERVED) |
PS(DKC) |
MODERATE |
No |
39 |
90 |
xx |
Undefined Package is mounted |
Processor |
MODERATE |
No |
39 |
91 |
xx |
V-R OR SERIAL NUMBER IS INCONSISTENT |
Processor |
MODERATE |
No |
39 |
93 |
xx |
REPLACE FAILED |
Processor |
MODERATE |
No |
39 |
9d |
xx |
Injustice DC voltage control |
Processor |
MODERATE |
Yes |
39 |
9e |
xx |
Injustice CEMODE |
Processor |
MODERATE |
Yes |
39 |
9f |
xx |
Injustice CEDT |
Processor |
MODERATE |
Yes |
39 |
b0 |
xx |
SMA SLAVE ERROR |
Processor |
SERVICE |
No |
39 | b2 | 00 | CPU frequency setting failure |
Processor | SERVICE |
No |
3a |
0x |
xx |
LDEV Blockade (Effect of microcode error) |
Processor |
MODERATE |
Yes |
3c |
95 |
00 |
CHB/DKB Type disagreement |
Processor |
MODERATE |
No |
3c |
96 |
00 |
No CHB mounted |
CHB/DKB error |
MODERATE |
No |
3c |
97 |
xx |
iSCSI firmware update warning |
CHB/DKB error |
MODERATE |
Yes |
41 |
00 |
xx |
Format complete |
Drive |
SERVICE |
No |
41 |
01 |
00 |
Quick Format finish |
Drive |
SERVICE |
No |
43 |
4x |
xx |
DRIVE MEDIA ERROR6 |
Drive |
SERVICE |
No |
43 |
5x |
xx |
Drive media error |
Drive |
SERVICE |
Yes |
43 |
ax |
xx |
Drive blockade (media)(with redundancy) |
Drive |
SERIOUS |
Yes |
43 |
bx |
xx |
Drive blockade (media)(with redundancy)6 |
Drive |
SERIOUS |
Yes |
43 |
cx |
xx |
Drive blockade (media)(without redundancy)6 |
Drive |
SERIOUS |
Yes |
43 |
dx |
xx |
Drive blockade (media)(without redundancy) |
Drive |
SERIOUS |
Yes |
45 |
1x |
xx |
CORRECTION COPY START6 |
Drive |
SERVICE |
Yes |
45 |
2x |
xx |
CORRECTION COPY NORMAL END6 |
Drive |
SERVICE |
Yes |
45 |
3x |
xx |
CORRECTION COPY ABNORMAL END6 |
Drive |
SERIOUS |
Yes |
45 |
4x |
xx |
CORRECTION COPY DISCONTINUED6 |
Drive |
SERVICE |
No |
45 |
5x |
xx |
Correction copy warning end(With blockade LDEV or some error)6 |
Drive |
SERVICE |
Yes |
46 |
1x |
xx |
DYNAMIC SPARING(DRIVE COPY)START6 |
Drive |
SERVICE |
Yes |
46 |
2x |
xx |
DYNAMIC SPARING(DRIVE COPY)NORMAL END6 |
Drive |
SERVICE |
Yes |
46 |
3x |
xx |
DYNAMIC SPARING(DRIVE COPY)ABNORMAL END6 |
Drive |
MODERATE |
Yes |
46 |
4x |
xx |
DYNAMIC SPARING(DRIVE COPY)DISCONTINUED6 |
Drive |
SERVICE |
No |
46 |
5x |
xx |
Dynamic sparing warning end(With blockade LDEV or some error)(Drive copy)6 |
Drive |
SERVICE |
Yes |
46 |
8x |
xx |
Collection Copy/Copyback disabled(drive replace) |
Drive |
MODERATE |
No |
46 |
9x |
xx |
Collection Copy/Copyback disabled(drive replace) |
Drive |
MODERATE |
No |
46 |
ax |
xx |
Drive Copy/Correction Copy delay |
Drive |
MODERATE |
Yes |
46 |
bx |
xx |
Drive Copy/Correction Copy delay |
Drive |
MODERATE |
Yes |
47 |
dx |
xx |
SIMF/SI Copy abnormal end |
Failure with paired volumes |
MODERATE |
Yes |
47 |
e5 |
00 |
All FlashCopy(R) Option abnormal end by SM volatile |
Failure with paired volumes |
MODERATE |
Yes |
47 |
e7 |
00 |
Forcible suspend by SM volatile (SIMF/SI) |
Failure with paired volumes |
MODERATE |
Yes |
47 |
ec |
00 |
Thin Image ABNORMAL END BY SM VOLATILE |
Failure with paired volumes |
MODERATE |
Yes |
47 |
fx |
xx |
Volume Migration Abnormal End |
Volume Migration |
MODERATE |
No3 |
49 |
10 |
00 |
CACHE WRITE PENDING RATIO IS OVER 65% |
Cache |
SERVICE |
No |
4a |
80 |
xx |
Expander Micro Exchange failed |
Processor |
MODERATE |
No |
4b |
2x |
xx |
Compatible FlashCopy(R) ABNORMAL END |
Failure with paired volumes |
MODERATE |
Yes |
4b |
3x |
xx |
Thin Image ABNORMAL END |
Failure with paired volumes |
MODERATE |
Yes |
4b |
4x |
xx |
FlashCopy(R) Hierarchical memory access error |
Failure with paired volumes |
MODERATE |
Yes |
4b |
6x |
xx |
Correction copy start |
Failure with paired volumes |
SERVICE |
Yes |
4b |
7x |
xx |
Correction copy start |
Failure with paired volumes |
SERVICE |
Yes |
4b |
8x |
xx |
Correction copy normal end |
Failure with paired volumes |
SERVICE |
Yes |
4b |
9x |
xx |
Correction copy normal end |
Failure with paired volumes |
SERVICE |
Yes |
4b |
ax |
xx |
Correction copy abnormal end |
Failure with paired volumes |
SERIOUS |
Yes |
4b |
bx |
xx |
Correction copy abnormal end |
Failure with paired volumes |
SERIOUS |
Yes |
4b |
cx |
xx |
Correction copy discontinued |
Failure with paired volumes |
SERVICE |
No |
4b |
dx |
xx |
Correction copy discontinued |
Failure with paired volumes |
SERVICE |
No |
4b |
ex |
xx |
Correction copy warning end (With blockade LDEV or some error) |
Failure with paired volumes |
SERVICE |
Yes |
4b |
fx |
xx |
Correction copy warning end (With blockade LDEV or some error) |
Failure with paired volumes |
SERVICE |
Yes |
4c |
10 |
xx |
PDEV Erase Start |
Drive |
SERVICE |
No |
4c |
20 |
xx |
PDEV Erase Normal End |
Drive |
SERVICE |
No |
4c |
30 |
xx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
No |
4c |
4x |
xx |
Flash module drive initialization failed |
Drive |
MODERATE |
Yes |
4c |
5x |
xx |
Flash module drive initialization failed |
Drive |
MODERATE |
Yes |
4c |
6x |
xx |
Dynamic sparing start (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
7x |
xx |
Dynamic sparing start (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
8x |
xx |
Dynamic sparing normal end (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
9x |
xx |
Dynamic sparing normal end (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
ax |
xx |
Dynamic sparing abnormal end (Drive copy) |
Drive |
MODERATE |
Yes |
4c |
bx |
xx |
Dynamic sparing abnormal end (Drive copy) |
Drive |
MODERATE |
Yes |
4c |
cx |
xx |
Dynamic sparing discontinued (Drive copy) |
Drive |
SERVICE |
No |
4c |
dx |
xx |
Dynamic sparing discontinued (Drive copy) |
Drive |
SERVICE |
No |
4c |
ex |
xx |
Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy) |
Drive |
SERVICE |
Yes |
4c |
fx |
xx |
Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy) |
Drive |
SERVICE |
Yes |
4d |
1x |
xx |
Differential area blocking |
Drive |
SERIOUS |
Yes |
4d |
6x |
xx |
PDEV Erase Start |
Drive |
SERVICE |
Yes |
4d |
7x |
xx |
PDEV Erase Start |
Drive |
SERVICE |
Yes |
4d |
8x |
xx |
PDEV Erase Normal End |
Drive |
SERVICE |
Yes |
4d |
9x |
xx |
PDEV Erase Normal End |
Drive |
SERVICE |
Yes |
4d |
ax |
xx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
Yes |
4d |
bx |
xx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
Yes |
50 |
0x |
xx |
Drive temporary error |
Drive |
SERVICE |
No |
50 |
1x |
xx |
DRIVE TEMPORARY ERROR |
Drive |
SERVICE |
No |
50 |
2x |
xx |
DRIVE MEDIA ERROR6 |
Drive |
SERVICE |
No |
50 |
3x |
xx |
Drive media error |
Drive |
SERVICE |
No |
50 |
5x |
xx |
Flash module drive internal battery error (ORM)6 |
Drive |
SERVICE |
No |
50 |
8x |
xx |
Flash module drive internal battery error6 |
Drive |
MODERATE |
No |
50 |
ax |
xx |
Flash drive End of life |
Drive |
SERVICE |
Yes |
50 |
bx |
xx |
Flash drive End of life6 |
Drive |
SERVICE |
Yes |
50 |
cx |
xx |
Flash module drive End of life6 |
Drive |
SERVICE |
Yes |
50 |
dx |
xx |
Flash module drive battery warning6 |
Drive |
SERVICE |
No |
60 |
2x |
xx |
Pool blocking7 |
Thin Image pool |
MODERATE |
Yes |
60 |
30 |
00 |
SM Space Warning |
SM |
MODERATE |
Yes4 |
60 |
4x |
xx |
Exceeded Threshold of pool use rate |
Thin Image pool |
MODERATE |
Yes |
60 |
5x |
xx |
Actual pool use rate reaches upper limit |
Thin Image pool |
MODERATE |
Yes |
60 |
6x |
xx |
Exceeded Fixed outage Threshold of pool use rate |
Thin Image pool |
MODERATE |
Yes |
61 |
00 |
xx |
BACKUP/RESTORE SM INFORMATION FAILED |
SM |
MODERATE |
No |
62 |
3x |
xx |
The DP POOL error is detected (XXX : Pool ID) |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
40 |
00 |
SM(DP/TI) AREA DEPLETION |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
7x |
xx |
The DP POOL LDEV blockade |
Dynamic Provisioning pool |
SERIOUS |
Yes |
62 |
80 |
00 |
DP Protect attribute setting of DRU |
Dynamic Provisioning pool |
SERIOUS |
Yes |
62 |
9x |
xx |
Exceeded Warning Threshold of DP pool use rate |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
ax |
xx |
DP pool use rate reaches upper limit |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
b0 |
00 |
Threshold of DP pool use rate remains exceeded |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
cx |
xx |
Exceeded Depletion Threshold of DP pool use rate |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
dx |
xx |
Exceeded Fixed outage Threshold of DPpool use rate |
Dynamic Provisioning pool |
MODERATE |
Yes |
62 |
ex |
xx |
Exceeded DP pool depletion threshold for TI pairs |
Dynamic Provisioning pool |
MODERATE |
Yes |
63 |
1x |
xx |
Auto pool expansion failed due to system error |
Dynamic Provisioning pool |
MODERATE |
Yes |
63 |
2x |
xx |
Auto pool expansion failed due to pool error |
Dynamic Provisioning pool |
MODERATE |
Yes |
63 |
3x |
xx |
Failed to create, expand, or delete pools |
Pool error |
MODERATE |
Yes |
63 |
4x |
xx |
Auto pool expansion failed due to no more LDEV IDs |
Dynamic Provisioning pool |
MODERATE |
Yes |
64 |
1x | xx |
Tier relocation is not completed | Dynamic Tiering pool |
SERVICE |
Yes |
66 |
01 |
00 |
No free encryption key |
Encryption key |
MODERATE |
Yes |
66 |
02 |
00 |
Remaining free encryption key warning |
Encryption key |
SERVICE |
Yes |
66 |
10 | xx |
Acquisition of encryption key from KMS failed |
Encryption key |
MODERATE |
Yes |
66 |
20 | xx |
Encryption key setting abnormality |
Processor |
SERIOUS |
Yes |
67 |
00 |
00 |
Warning for depletion of cache management devices |
Thin Image |
MODERATE |
Yes |
68 | 00 | xx | Dedupe and compression abnormality detect | DKC environment | MODERATE | Yes |
68 |
1x | xx |
dedupe System Volume delection abnormal end |
dedupe and compression failure |
MODERATE |
Yes |
68 |
20 |
00 |
dedupe System Volume delection suspended |
dedupe and compression failure |
MODERATE |
Yes |
70 |
xx |
00 |
Logical inconsistency |
SVP failure |
MODERATE |
No |
71 |
xx |
00 |
Heap error |
SVP failure |
MODERATE |
No |
72 |
xx |
00 |
File error |
SVP failure |
MODERATE |
No |
73 |
xx |
00 |
LAN error |
SVP failure |
MODERATE |
No |
74 |
xx |
xx |
SSVP error |
SVP failure |
MODERATE |
Yes |
75 |
xx |
00 |
Windows error |
SVP failure |
MODERATE |
No |
76 |
00 |
00 |
CUDG3 detected error |
SVP failure |
MODERATE |
No |
76 |
04 |
00 |
CUDG3 detected error |
SVP failure |
MODERATE |
No |
76 |
10 |
00 |
LCDG3 detected error |
SVP failure |
MODERATE |
No |
7a |
00 |
00 |
NORMAL END |
SVP failure |
SERVICE |
No |
7a |
01 |
00 |
ABNORMAL END(SVP) |
SVP failure |
SERVICE |
No |
7a |
02 |
00 |
ABNORMAL END(MP) |
SVP failure |
SERVICE |
No |
7a |
03 |
xx |
VERSION CHK ERROR |
SVP failure |
SERVICE |
No |
7a |
04 |
xx |
Sum check error |
SVP failure |
SERVICE |
No |
7a |
05 |
xx |
HTP patch error |
SVP failure |
SERVICE |
No |
7a |
10 |
00 |
WARNING(CONFIGURATION INCONSISTENCY) |
SVP failure |
SERVICE |
No |
7a |
11 |
00 |
WARNING(S-SVP BUSY) |
SVP failure |
SERVICE |
No |
7a |
12 |
xx |
Warning (HTP busy) |
SVP failure |
SERVICE |
No |
7a |
20 |
00 |
INTERNET DOWNLOAD ERROR |
SVP failure |
SERVICE |
No |
7a |
23 |
00 |
Discontinuation by the user |
SVP failure |
SERVICE |
No |
7b |
00 |
03 |
ISDN Router failure |
SVP failure |
MODERATE |
Yes |
7c |
00 |
00 |
SVP reboot stop (FD Inserted) |
SVP failure |
MODERATE |
No |
7c |
02 |
00 |
Audit Log failure of Host instruction configuration change |
SVP failure |
MODERATE |
No |
7c |
03 |
00 |
Audit Log FTP Transfer failed |
SVP failure |
MODERATE |
Yes |
7c |
04 |
00 |
Dump Tool failed |
SVP failure |
SERVICE |
Yes |
7c |
05 |
00 |
Invalid SIM data detection |
SVP failure |
SERVICE |
No |
7c | 08 | 00 | Dump collection starts | SVP failure | SERVICE | No |
7c | 09 | 00 | Dump collection ends normally | SVP failure | SERVICE | No |
7c | 0a | 00 | Dump collection ends abnormally | SVP failure | SERVICE | No |
7c | 0b | 00 | Cancellation of the dump collection completed | SVP failure | SERVICE | No |
7d |
00 |
xx |
GUM error |
GUM detection error |
MODERATE |
No |
7d |
01 |
xx |
LAN error(Internal Network) |
GUM detection error |
MODERATE |
Yes |
7d |
02 |
xx |
LAN error(CTL1-CTL2) |
GUM detection error |
MODERATE |
Yes |
7d |
06 |
xx |
MP error |
GUM detection error |
MODERATE |
Yes |
7d |
07 |
xx |
GUM security error detected |
GUM detection error |
MODERATE |
Yes |
7d |
08 |
xx |
Failed to recover GUM configuration information |
GUM detection error |
MODERATE |
Yes |
7d |
09 |
0x |
DKC warning |
GUM detection error |
SERIOUS |
Yes |
7d |
0a |
xx |
GUM version warning |
GUM detection error |
MODERATE |
Yes |
7e |
12 |
xx |
MP Operating Ratio Error |
Monitor |
MODERATE |
Yes |
7e |
20 |
xx |
Loss Of Signal Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
21 |
xx |
Bad Received Character Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
22 |
xx |
Loss Of Synchronization Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
23 |
xx |
Link Failure Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
24 |
xx |
Received EOFa Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
25 |
xx |
Discarded Frame Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
26 |
xx |
Bad CRC Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
27 |
xx |
Protocol Error Count(Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
28 |
xx |
Expired Frame Count (Fibre) Excess |
Monitor |
MODERATE |
No |
7e |
29 |
xx |
HTP/FNP Multiplicity Excess |
Monitor |
MODERATE |
No |
7e |
2a |
xx |
FEC Un-correctable Count(Fibre) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
2c |
xx |
HTP/FNP Read Data Transfer Ratio Error |
Monitor |
MODERATE |
No |
7e |
2d |
xx |
HTP/FNP Write Data Transfer Ratio Error |
Monitor |
MODERATE |
No |
7e |
2e |
xx |
HTP/FNP Operating Ratio Error |
Monitor |
MODERATE |
No |
7e |
30 |
00 |
Read Hit Ratio Excess |
Monitor |
MODERATE |
No |
7e |
50 |
xx |
MAC CRC Error Count(iSCSI) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
51 |
xx |
IP Error Packet Count(iSCSI) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
52 |
xx |
IPv6 Error Packet Count(iSCSI) threshold exceeded |
Monitor |
MODERATE |
No |
7e |
53 |
xx |
TCP Retransmit Timer Expired Count(iSCSI) exceeded |
Monitor |
MODERATE |
No |
7e |
54 |
xx |
iSCSI Header Digest Error Count(iSCSI) exceeded |
Monitor |
MODERATE |
No |
7e |
55 |
xx |
iSCSI Data Digest Error Count(iSCSI) exceeded |
Monitor |
MODERATE |
No |
7e |
ax |
xx |
Cache Use Ratio Error |
Monitor |
MODERATE |
No |
7e |
bx |
xx |
Cache Write Pending Ratio Error |
Monitor |
MODERATE |
No |
7e |
cx |
xx |
Cache MCU Side File Use Ratio Error |
Monitor |
MODERATE |
No |
7f |
f1 |
00 |
TCMF/TC |
SVP failure |
SERVICE |
No |
7f |
f1 |
02 |
SIMF/SI |
SVP failure |
SERVICE |
No |
7f |
f1 |
03 |
URMF/UR |
SVP failure |
SERVICE |
No |
7f |
f1 |
04 |
TI |
SVP failure |
SERVICE |
No |
7f |
f1 |
05 |
FlashCopy(R) |
SVP failure |
SERVICE |
No |
7f |
f1 |
06 |
Volume Migration |
SVP failure |
SERVICE |
No |
7f |
f2 |
xx |
STANDBY SVP FAIL |
SVP failure |
MODERATE |
No |
7f |
f3 |
xx |
SVP FAIL OVER |
SVP failure |
MODERATE |
No |
7f |
f7 |
xx |
The term of validity is over |
License key |
MODERATE |
Yes |
7f |
f8 |
xx |
The capacity of validity is over |
License key |
MODERATE |
Yes |
7f |
f9 |
xx |
The PP is invalid by assumption PP invalidity |
License key |
MODERATE |
Yes |
7f |
fa |
0x |
Synchronization time failure |
SVP failure |
SERVICE |
Yes |
ac |
50 |
xx |
DB power off |
PS(DKU) |
MODERATE |
Yes |
ac |
51 |
xx |
DB power recovered |
PS(DKU) |
SERVICE |
Yes |
ac |
60 |
00 |
DKC was set to power error mode |
PS(DKC) |
MODERATE |
No |
ac |
61 |
00 |
DKC was released from power error mode |
PS(DKC) |
SERVICE |
No |
ac |
62 |
00 |
When DKC was set to power error mode, Urgent Destaging start succeeded |
PS(DKC) |
SERVICE |
No |
ac |
63 |
00 |
When DKC was set to power error mode, Urgent Destaging start failed. |
PS(DKC) |
MODERATE |
No |
af |
00 |
xx |
Injustice JP Warning |
Environmental error |
MODERATE |
Yes |
af |
10 |
xx |
MP Temperature abnormality warning |
Environmental error |
MODERATE |
Yes |
af |
11 |
xx |
External temperature warning |
Environmental error |
MODERATE |
Yes |
af |
12 |
xx |
External temperature alarm |
Environmental error |
MODERATE |
Yes |
af |
13 |
xx |
Thermal monitor warning |
Environmental error |
MODERATE |
Yes |
af |
20 |
xx |
DKCPS warning |
Environmental error |
MODERATE |
Yes |
af |
21 |
xx |
DKCPS input voltage abnormality |
Environmental error |
MODERATE |
Yes |
af |
30 |
xx |
Environmental microcontroller warning |
Environmental error |
MODERATE |
Yes |
af |
31 |
xx |
Device movement mode warning |
Environmental error |
MODERATE |
Yes |
af |
32 |
xx |
Environmental Firmware Update warning |
Environmental error |
MODERATE |
Yes |
af |
33 |
xx |
Voltage change setting warning |
Environmental error |
MODERATE |
Yes |
af |
40 |
xx |
BKM/BKMF warning |
Environmental error |
MODERATE |
Yes |
af |
41 |
xx |
Battery replacement should be scheduled |
Environmental error |
MODERATE |
Yes |
af |
4d |
xx |
Panel switch warning |
Environmental error |
MODERATE |
Yes |
af |
4e |
xx |
Invalid PS ON warning |
Environmental error |
MODERATE |
Yes |
af |
51 |
xx |
DBPS-1 warning |
PS(DKU) |
MODERATE |
Yes |
af |
52 |
xx |
DBPS-2 warning |
PS(DKU) |
MODERATE |
Yes |
af |
61 |
xx |
DBPS-1 input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af |
62 |
xx |
DBPS-2 input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af |
70 |
00 |
DB External temperature warning |
Environmental error |
MODERATE |
Yes |
af |
71 |
00 |
DB External temperature Alarm |
Environmental error |
MODERATE |
Yes |
af |
81 |
xx |
ENC-1 warning |
Environmental error |
MODERATE |
Yes |
af |
82 |
xx |
ENC-2 warning |
Environmental error |
MODERATE |
Yes |
af |
b0 |
xx |
HSNBX ambient temperature warning |
Environmental error |
MODERATE |
Yes |
af |
b1 |
xx |
ISW PS warning |
Environmental error |
MODERATE |
Yes |
af |
b2 |
xx |
ISW FAN warning |
Environmental error |
MODERATE |
Yes |
af |
b3 |
xx |
ISW PS input voltage abnormality |
Environmental error |
MODERATE |
Yes |
af |
b4 |
xx |
ISW warning |
Environmental error |
MODERATE |
Yes |
af |
b5 |
xx |
HSNBX thermal monitor warning |
Environmental error |
MODERATE |
Yes |
af |
b6 |
xx |
HSNBX PANEL JP setting abnormality |
Environmental error |
MODERATE |
Yes |
af |
b7 |
xx |
HSNBX PANEL JP setting warning |
Environmental error |
MODERATE |
Yes |
af |
b8 |
xx |
HSNBX PSONOFF I/F inconsistent |
Environmental error |
MODERATE |
Yes |
af |
f0 |
xx |
SSW data disagreement |
DKC environment |
MODERATE |
No |
af |
f1 |
xx |
GUM warning |
Environmental error |
MODERATE |
Yes |
af |
f2 |
xx |
CFM error |
Processor |
MODERATE |
Yes |
af |
f3 |
xx |
FAN warning |
Environmental error |
MODERATE |
Yes |
bf |
85 |
a3 |
JP remains |
Environment |
MODERATE |
Yes |
bf |
86 |
a3 |
JP remains |
Environment |
MODERATE |
Yes |
bf |
aa |
a0 |
DKCPS I/F disagreement |
DKC environment |
MODERATE |
No |
bf |
aa |
a4 |
DKCPS I/F disagreement |
DKC environment |
MODERATE |
No |
bf |
ab |
a0 |
DKCPS I/F disagreement |
DKC environment |
MODERATE |
No |
bf |
ab |
a4 |
DKCPS I/F disagreement |
DKC environment |
MODERATE |
No |
bf |
ac |
a0 |
Communication Error between MN and MN |
Environment |
MODERATE |
No |
bf |
ac |
a1 |
Communication Error between MN and MN |
Environment |
MODERATE |
No |
bf |
ac |
a4 |
Communication Error between MN and MN |
Environment |
MODERATE |
No |
bf |
ac |
a5 |
Communication Error between MN and MN |
Environment |
MODERATE |
No |
bf |
ad |
a3 |
Cable connection error |
Environment |
MODERATE |
No |
bf |
ad |
a4 |
Cable connection error |
Environment |
MODERATE |
No |
bf |
ae |
a1 |
Cable connection error |
Environment |
MODERATE |
No |
bf |
af |
a0 |
PCTL/PNL abnormally |
Environment |
MODERATE |
No |
bf |
af |
a4 |
PCTL/PNL abnormally |
Environment |
MODERATE |
No |
bf |
bx |
xx |
HSNPANEL error |
Environmental error |
MODERATE |
No |
bf |
c0 |
10 |
DKC ALARM LED light on |
DKC environment |
SERIOUS |
Yes |
bf |
e3 |
a2 |
Duplex SVP Setup fail |
SVP failure |
MODERATE |
Yes |
bf |
e4 |
00 |
SVP FAN0 error |
SVP failure |
MODERATE |
No |
bf |
e4 |
01 |
SVP FAN1 error |
SVP failure |
MODERATE |
No |
bf |
e4 |
02 |
SVP FAN2 error |
SVP failure |
MODERATE |
No |
bf |
e4 |
04 |
SVP disk error (SMART) |
Environmental error |
MODERATE |
No |
bf |
e4 |
06 |
EXTENDER Hardware error |
SVP failure |
MODERATE |
No |
bf |
e4 |
07 |
USB interface error |
Environmental error |
MODERATE |
No |
bf |
e4 |
08 |
SVP receiving voltage error (CL1) |
SVP failure |
MODERATE |
No |
bf |
e4 |
09 |
SVP receiving voltage error (CL2) |
SVP failure |
MODERATE |
No |
cf |
10 |
xx |
SAS CTL blocking |
Processor |
MODERATE |
Yes |
cf |
11 |
xx |
SAS Port (WideLink) is partially blocked |
Processor |
SERVICE |
No |
cf |
12 |
xx |
SAS PORT blocked |
Processor |
MODERATE |
Yes |
cf |
13 |
xx |
Abnormal error detection |
Processor |
SERIOUS |
Yes |
cf |
20 |
xx |
PSW blockade |
Processor |
MODERATE |
Yes |
cf |
22 |
xx |
NVMe port blockade |
Processor |
MODERATE |
Yes |
cf |
88 |
xx |
CTL blocking |
Processor |
MODERATE |
Yes |
d0 |
0x |
xx |
TCMF/TC started the initial copy or out of sync for this volume |
Failure with paired volumes |
SERVICE |
Yes |
d0 |
1x |
xx |
TCMF/TC completed the initial copy for this volume |
Failure with paired volumes |
SERVICE |
Yes |
d0 |
2x |
xx |
TCMF/TC for this volume was deleted(Operation from an SVP/Web Console or a host processor) |
Failure with paired volumes |
SERVICE |
Yes |
d0 |
6x |
xx |
TCMF completed the Create pair (No copy suspend) |
Pair volume status error |
SERVICE |
Yes |
d1 |
0x |
xx |
Remote Copy pair status change (MCU Command) (From Simplex to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
1x |
xx |
Remote Copy pair status change (MCU Command) (From Simplex to Duplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
2x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Duplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
3x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
4x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex to Suspend) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
5x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex to Simplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
6x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Simplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
7x |
xx |
Remote Copy pair status change (MCU Command) (From Suspend to Simplex) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
8x |
xx |
Remote Copy pair status change (MCU Command) (From Suspend to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
9x |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend(continue)) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
ax |
xx |
Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend(complete)) |
Failure with paired volumes |
SERVICE |
Yes |
d1 |
bx |
xx |
Remote Copy pair status change (MCU Command) (From Suspend (continue) to Suspend) |
Failure with paired volumes |
SERVICE |
Yes |
d4 |
0x |
xx |
TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
1x |
xx |
TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the P-VOL or the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
2x |
xx |
TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the S-VOL) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
3x |
xx |
TCMF for this volume was suspended (Caused by DFW to the S-VOL was prohibited) |
Pair volume status error |
SERIOUS |
Yes |
d4 |
4x |
xx |
TCMF/TC for this volume was suspended (Due to an internal error condition detected by the RCU) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
5x |
xx |
TCMF/TC for this volume was suspended (Caused by Delete pair operation was issued to the S-VOL) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
6x |
xx |
The S-VOL has suspended. (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
7x |
xx |
The S-VOL has suspended (Due to an unrecoverable failure on the S-VOL) |
Failure with paired volumes |
SERIOUS |
Yes |
d4 |
fx |
xx |
Status of the P-VOL was not consistent with the S-VOL |
Failure with paired volumes |
SERIOUS |
Yes |
d5 |
7x |
xx |
Command device operation execution of command device in state of ONLINE |
Drive |
SERVICE |
No |
d8 |
0x |
xx |
A volume to be used by the URMF/UR was defined |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
1x |
xx |
The volume being used by the URMF/UR began a copying |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
2x |
xx |
The volume being used by the URMF/UR completed a copying |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
3x |
xx |
The volume being used by the URMF/UR received a request for suspension |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
4x |
xx |
The volume being used by the URMF/UR completed a suspension transaction |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
5x |
xx |
The volume being used by the URMF/UR received a request for deletion |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
6x |
xx |
The volume being used by the URMF/UR completed the deletion |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
7x |
xx |
The volume being used by the URMF/UR was defined (placed in the PSUS status immediately) |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
8x |
xx |
A Delta volume to be used by the URMF/UR was defined |
Failure with paired volumes |
SERVICE |
Yes5 |
d8 |
9x |
xx |
A Delta volume to be used by the URMF/UR was redefined |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
0x |
xx |
A change to an S-VOL was received from the MCU (From Simplex to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
1x |
xx |
A change to an S-VOL was received from the MCU (From Simplex to Duplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
2x |
xx |
A change to an S-VOL was received from the MCU (From Duplex Pending to Duplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
3x |
xx |
A change to an S-VOL was received from the MCU (From Duplex Pending to Suspend) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
4x |
xx |
A change to an S-VOL was received from the MCU (From Duplex to Suspend) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
5x |
xx |
A change to an S-VOL was received from the MCU (From Duplex to Simplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
6x |
xx |
A change to an S-VOL was received from the MCU (From Duplex Pending to Simplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
7x |
xx |
A change to an S-VOL was received from the MCU (From Suspend to Simplex) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
8x |
xx |
A change to an S-VOL was received from the MCU (From Suspend to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
9x |
xx |
A change to an S-VOL was received from the MCU (HOLD -> PAIR) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
ax |
xx |
A change to an S-VOL was received from the MCU (HOLD -> COPY) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
bx |
xx |
A change to an S-VOL was received from the MCU (HOLD -> SMPL) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
cx |
xx |
A change to an S-VOL was received from the MCU (From Simplex to Suspend) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
dx |
xx |
A change to an S-VOL was received from the MCU (SMPL -> HOLD) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
ex |
xx |
A change to an S-VOL was received from the MCU (PSUx(Suspend) -> HOLD) |
Failure with paired volumes |
SERVICE |
Yes5 |
d9 |
fx |
xx |
A change to an S-VOL was received from the MCU (From Duplex to Duplex Pending) |
Failure with paired volumes |
SERVICE |
Yes5 |
da |
0x |
xx |
A change to an S-VOL was received from the RCU (A request for suspension was received.) |
Failure with paired volumes |
SERVICE |
No |
da |
1x |
xx |
A change to an S-VOL was received from the RCU (A suspension transaction was completed.) |
Failure with paired volumes |
SERVICE |
No |
da |
2x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Suspend status.) |
Failure with paired volumes |
SERVICE |
No |
da |
3x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Duplex Pending status.) |
Failure with paired volumes |
SERVICE |
No |
da |
4x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Duplex status.) |
Failure with paired volumes |
SERVICE |
No |
da |
5x |
xx |
A change to an S-VOL was received from the RCU (A pair deletion was completed.) |
Failure with paired volumes |
SERVICE |
No |
da |
6x |
xx |
A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Hold status.) |
Failure with paired volumes |
SERVICE |
No |
db |
0x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
Yes |
db |
1x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
Yes |
db |
2x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
Yes |
db |
3x |
xx |
Drive port temporary error |
Drive error |
SERVICE |
Yes |
db |
4x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
5x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
6x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
7x |
xx |
Drive port blockade |
Drive error |
MODERATE |
Yes |
db |
8x |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
9x |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
ax |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
bx |
xx |
LDEV blockade (Effect of Drive port blockade) |
Drive error |
SERIOUS |
Yes |
db |
cx |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
db |
dx |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
db |
ex |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
db |
fx |
xx |
Drive Link Rate Abnormality |
Drive error |
SERVICE |
Yes |
dc |
0x |
xx |
PAIR SUSPEND(RIO PATH CLOSE) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
1x |
xx |
PAIR SUSPEND(MVOL ERROR) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
2x |
xx |
PAIR SUSPEND(RVOL ERROR) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
4x |
xx |
PAIR SUSPEND(SUSPEND REPORT) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
5x |
xx |
PAIR SUSPEND(SIMPLEX REPORT) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
6x |
xx |
PAIR SUSPEND(COMMUNICATION ERROR AT RCU) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
7x |
xx |
PAIR SUSPEND(ERROR DETECTED AT RCU) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
8x |
xx |
A volume being used by an S-VOL was suspended (PS OFF on the MCU side was detected) |
Failure with paired volumes |
SERVICE |
No |
dc |
9x |
xx |
ERASE FAIL |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
ax |
xx |
Pair suspend (Spread by error of another Affiliate) |
Failure with paired volumes |
SERIOUS |
Yes5 |
dc |
e0 |
xx |
URMF/UR M-JNL Meta overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
e1 |
xx |
URMF/UR M-JNL Data overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
e2 |
xx |
URMF/UR R-JNL Meta overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
e3 |
xx |
URMF/UR R-JNL Data overflow warning |
Failure with paired volumes |
MODERATE |
No |
dc |
f0 |
xx |
The URMF/UR Read JNL was interrupted for one minute (A failure on the MCU side was detected) |
Failure with paired volumes |
MODERATE |
No |
dc |
f1 |
xx |
The URMF/UR Read JNL was interrupted for five minutes (A failure on the MCU side was detected) |
Failure with paired volumes |
SERIOUS |
No |
dc |
f2 |
xx |
The URMF/UR Read JNL was interrupted for one minute (A failure on the RCU side was detected) |
Failure with paired volumes |
MODERATE |
No |
dc |
f3 |
xx |
The URMF/UR Read JNL was interrupted for five minutes (A failure on the RCU side was detected) |
Failure with paired volumes |
SERIOUS |
No |
dc |
f4 |
xx |
URMFxURMF/URxUR M-JNL Meta full Warning |
Failure with paired volumes |
MODERATE |
No |
dc |
f5 |
xx |
URMFxURMF/URxUR M-JNL Data full Warning |
Failure with paired volumes |
MODERATE |
No |
dd |
0x |
xx |
GAD for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
1x |
xx |
GAD for this volume was suspended (Due to a failure on the volume) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
2x |
xx |
GAD for this volume was suspended (Due to an internal error condition detected) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
3x |
xx |
Status of the P-VOL was not consistent with the S-VOL |
Failure with paired volumes |
SERIOUS |
Yes |
de |
e0 |
xx |
Quorum Disk Restore |
Drive |
SERVICE |
Yes |
de |
f0 |
xx |
Quorum Disk Blocked |
Drive |
SERIOUS |
Yes |
df |
6x |
xx |
Drive port temporary error (Drive path: Boundary 0)6 |
Drive |
SERVICE |
No |
df |
7x |
xx |
Drive port temporary error (Drive path: Boundary 1)6 |
Drive |
SERVICE |
No |
df |
8x |
xx |
DRIVE PORT BLOCKADE(PATH 0)6 |
Drive |
MODERATE |
Yes |
df |
9x |
xx |
DRIVE PORT BLOCKADE(PATH 1)6 |
Drive |
MODERATE |
Yes |
df |
ax |
xx |
LDEV blockade(Drive path: Boundary 0/Effect of Drive port blockade)6 |
Drive |
SERIOUS |
Yes |
df |
bx |
xx |
LDEV blockade(Drive path: Boundary 1/Effect of Drive port blockade)6 |
Drive |
SERIOUS |
Yes |
df |
cx |
xx |
Drive Link Rate Abnormality (Path 0)6 |
Drive |
SERVICE |
Yes |
df |
dx |
xx |
Drive Link Rate Abnormality (Path 1)6 |
Drive |
SERVICE |
Yes |
df |
ex |
xx |
Response late Drive |
Drive |
SERVICE |
Yes |
df |
fx |
xx |
Response late Drive6 |
Drive |
SERVICE |
No |
eb |
0x |
xx |
Drive blockade (drive)(with redundancy) |
Drive |
SERIOUS |
Yes |
eb |
1x |
xx |
Drive blockade (drive)(with redundancy) |
Drive |
SERIOUS |
Yes |
eb |
2x |
xx |
Drive blockade (drive)(without redundancy) |
Drive |
SERIOUS |
Yes |
eb |
3x |
xx |
Drive blockade (drive)(without redundancy) |
Drive |
SERIOUS |
Yes |
eb |
4x |
xx |
Drive blockade (Effect of Dynamic sparing normal end) |
Drive |
SERVICE |
Yes |
eb |
5x |
xx |
Drive blockade (Effect of Dynamic sparing normal end) |
Drive |
SERVICE |
Yes |
eb |
6x |
xx |
Correction access occurred |
Drive |
SERIOUS |
Yes |
eb |
7x |
xx |
Correction access occurred |
Drive |
SERIOUS |
Yes |
eb |
8x |
xx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
No |
eb |
9x |
xx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
No |
ee |
00 |
00 |
Volume I/O upper limit reached |
QoS alert |
SERVICE |
Yes |
ef |
0x |
xx |
Drive blockade (drive)(with redundancy)6 |
Drive |
SERIOUS |
Yes |
ef |
1x |
xx |
Drive blockade (drive) (without redundancy)6 |
Drive |
SERIOUS |
Yes |
ef |
2x |
xx |
DRIVE BLOCKADE(EFFECT OF DRIVE COPY NORMAL END)6 |
Drive |
SERVICE |
Yes |
ef |
4x |
xx |
PINNED SLOT |
Drive |
MODERATE |
No |
ef |
5x |
xx |
Abnormal end of Write processing in External storage system |
Drive |
MODERATE |
No |
ef |
8x |
xx |
LDEV blockade (Effect of drive blockade) |
Drive |
SERIOUS |
Yes |
ef |
9x |
xx |
LDEV blockade (Effect of drive blockade)6 |
Drive |
SERIOUS |
Yes |
ef |
ax |
xx |
DRIVE TEMPORARY ERROR6 |
Drive |
SERVICE |
No |
ef |
bx |
xx |
Drive temporary error |
Drive |
SERVICE |
Yes |
ef |
cx |
xx |
Correction access occurred6 |
Drive |
SERIOUS |
Yes |
ef |
d0 |
00 |
External storage system connection device blockade |
Drive |
SERIOUS |
Yes |
ef |
d4 |
00 |
Blocking the Data Migration source device |
Drive |
MODERATE |
No |
ef |
fd |
xx |
Expander failure |
Environmental error |
SERIOUS |
Yes |
ef |
fe |
xx |
UNIT CONNECTION ERROR |
DKC environment |
MODERATE |
Yes |
fe |
00 |
00 |
Cache battery is being charged |
Cache |
SERIOUS |
Yes |
fe |
01 |
0x |
End of Cache Write Through |
Cache |
SERVICE |
No |
fe |
02 |
0x |
Start of Cache Write Through |
Cache |
MODERATE |
Yes |
fe |
03 |
0x |
Cache SSD mounting capacity shortage |
Cache |
SERIOUS |
No |
fe |
04 |
xx |
No CHB mounted |
Cache |
SERIOUS |
Yes |
ff |
21 |
xx |
LANB blocking |
Processor |
MODERATE |
Yes |
ff |
4x |
xx |
PINNED SLOT |
Cache |
MODERATE |
No |
ff |
5x |
xx |
Abnormal end of Read processing in External storage system |
Drive |
MODERATE |
No |
ff |
c3 |
0x |
CACHE PACKAGE BLOCKADE PROCESSING END |
Cache |
SERVICE |
Yes |
ff |
cb |
xx |
CTL patrol check error |
Cache |
SERVICE |
No |
ff |
cc |
xx |
CFM patrol check error |
Cache |
MODERATE |
No |
ff |
cd |
0x |
Area is volatilized |
Cache |
SERVICE |
No |
ff |
cf |
xx |
Package is volatilized |
Cache |
SERVICE |
No |
ff |
d4 |
xx |
Constitution definition error |
Processor |
MODERATE |
No |
ff |
de |
xx |
WDCP loss of duplicated information |
SM |
SERVICE |
No |
ff |
e4 |
0x |
REPLACE FAILED |
Cache |
SERIOUS |
No |
ff |
e7 |
00 |
Rebooted with volatilization after an instantaneous down |
SM |
SERIOUS |
Yes |
ff |
e8 |
00 |
Definition/Installation mismatch |
SM |
ACUTE |
No |
ff |
ea |
0x |
RECOVERY OF AREA BLOCKED TEMPORARILY WAS COMPLETED |
SM |
SERVICE |
Yes |
ff |
eb |
00 |
Configuration information restore by backup failed |
SM |
SERIOUS |
Yes |
ff |
ee |
0x |
AREA TEMPORARY BLOCKING |
SM |
SERVICE |
Yes |
ff |
ef |
00 |
Rebooted without volatilization after an instantaneous down |
SM |
SERVICE |
No |
ff |
f0 |
xx |
DIMM Correctable error |
Cache |
SERVICE |
No |
ff |
f3 |
0x |
PACKAGE BLOCKING |
Cache |
MODERATE |
Yes |
ff |
f4 |
00 |
AREA BLOCKING |
Cache |
SERIOUS |
Yes |
ff |
f4 |
01 |
AREA BLOCKING |
Cache |
SERIOUS |
Yes |
ff |
f5 |
0x |
Both areas failed |
Cache |
MODERATE |
No |
ff |
f6 |
xx |
CM Injustice dc voltage control |
Cache |
MODERATE |
No |
ff |
f7 |
xx |
GUM blocking |
Cache |
MODERATE |
Yes |
ff |
f9 |
0x |
REPLACE FAILED |
Cache |
SERVICE |
No |
ff |
fa |
xx |
Battery warning |
Battery |
MODERATE |
No |
ff |
fb |
xx |
CMBK warning |
Cache |
MODERATE |
No |
ff |
fc |
xx |
CM Temperature abnormality warning |
Cache |
MODERATE |
No |
ff |
fe |
xx |
Warning for forcible volatile mode |
Cache |
MODERATE |
No |
Legend:
|
Converting CDEV and RDEV numbers to box and drive numbers
To identify the location of an error, convert the CDEV and RDEV numbers to box and drive numbers.
CDEV and RDEV numbers are output as hexadecimal numbers in the following format:
The base drive box number is a three-digit octal number that is mapped to a specific two-digit hexadecimal CDEV number. The following table lists drive box numbers based on the first and second digits of the CDEV numbers.
Second digit of CDEV |
First digit of CDEV | |||||
0_ |
1_ |
2_ |
3_ |
4_ |
5_ | |
_0 | 000 | 020 | 040 | 100 | 120 | 140 |
_1 | 002 | 022 | 042 | 102 | 122 | 142 |
_2 | 004 | 024 | 044 | 104 | 124 | 144 |
_3 | 006 | 026 | 046 | 106 | 126 | 146 |
_4 | 001 | 021 | 041 | 101 | 121 | 141 |
_5 | 003 | 023 | 043 | 103 | 123 | 143 |
_6 | 005 | 025 | 045 | 105 | 125 | 145 |
_7 | 007 | 027 | 047 | 107 | 127 | 147 |
_8 | 010 | 030 | 050 | 110 | 130 | 150 |
_9 | 012 | 032 | 052 | 112 | 132 | 152 |
_A | 014 | 034 | 054 | 114 | 134 | 154 |
_B | 016 | 036 | 056 | 116 | 136 | 156 |
_C | 011 | 031 | 051 | 111 | 131 | 151 |
_D | 013 | 033 | 053 | 113 | 133 | 153 |
_E | 015 | 035 | 055 | 115 | 135 | 155 |
_F | 017 | 037 | 057 | 117 | 137 | 157 |
For example:
- CDEV 42 corresponds to drive box 124.
- CDEV 5F corresponds to drive box 157.
The base drive number is the RDEV number converted from hexadecimal to a two-digit decimal number. For example:
- RDEV 0C corresponds to drive 12.
- RDEV 22 corresponds to drive 16.
The format for a specific drive in a specific drive box is:
- Drive box number
HDU-<mapped-CDEV-number>
- Drive number
HDD<mapped-CDEV-number>-<converted-RDEV-number>
The following table provides examples of CDEV and RDEV numbers and their corresponding drive box and drive numbers.
CDEV#/RDEV# | Drive box number | Drive number |
04/02 | HDU-001 | HDD001-02 |
3F/0A | HDU-117 | HDD117-10 |
45/15 | HDU-123 | HDD123-21 |