Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

UR CLI reference

You can use lists of Universal Replicator operations and the corresponding CLI commands (CCI) as a reference guide.

Configuration operations

The following table lists the UR configuration operations and provides the corresponding CCI commands.

Operation

Options

In HDvM - SN?

CCI command and options

Edit Ports (VSP 5000 series)

Port Attribute

Yes

raidcom modify port

-port_attribute port attribute

Add Remote Connection

Connection Type (VSP 5000 series)

Yes

None

Remote Storage System

Yes3

raidcom add rcu

-rcu serial# mcu# rcu# id

Remote Paths

Yes3

raidcom add rcu

-cu_free serial# id pid

RIO MIH Time

Yes3

raidcom modify rcu

-rcu_option mpth rto rtt[fzd|fze]

Create Journals (VSP 5000 series)

System Type

Yes

raidcom add journal

[-timer_type timer_type]1

Journal ID

Yes

raidcom add journal

-journal_id journal ID#

Journal Type Options2: Data Overflow Watch, Cache Mode, and Timer Type

Yes

raidcom modify journal

[-data_overflow_watchtime] [-cache_mode {y | n}][-timer_type timer type]

Journal Type Options2: Path Blockade Watch

Yes

raidcom modify journal

-path_blocked_watchtime [-mirror_id mu#]

Journal Type Options2:Specifies MP Unit

Yes

raidcom modify journal

-mp_blade_id mp#

Create Journal ( VSP E series)

Journal ID

Yes

raidcom add journal

-journal_id journal ID#

MP Unit ID2

Yes

raidcom modify journal

-mp_blade_id mp#

Data Overflow Watch2

Yes

raidcom modify journal

-data_overflow_watch time

Cache Mode2

Yes

raidcom modify journal

-cache_mode {y|n}

Edit Journal Options ( VSP E series)

Data Overflow Watch2

Yes

raidcom modify journal

-data_overflow_watch time

Cache Mode2

Yes

raidcom modify journal

-cache_mode {y|n}

Assign Journal Volume

None

Yes

raidcom add journal

-journal_id journalID#

Add Reserve Journal Volume (VSP 5000 series)

None

Yes

raidcom add journal

-journal_id journalID#

-ldev_id ldev#

Assign MP Unit ID

MP Unit ID

Yes

raidcom add journal

[ -mp_blade_id mp# ]

Edit Remote Replica Options

Copy Type

Yes

None

Maximum Initial Copy Activities

Yes

None

Notes:

  1. (VSP 5000 series) The journal will be created as an open system journal if you do not specify the -timer_type option. If you specify -timer_type, the journal will be created for mainframe systems.
  2. Data Overflow Watch, Cache Mode, Timer Type, Path Blockade Watch, and MP Unit ID can only be specified all at once during the create journal operation using Device Manager - Storage Navigator. You can only specify them one-by-one with CCI and also you can modify the journal type options. For details, see the Command Control Interface User and Reference Guide.

Pair operations

For you to be able to manage UR pairs, you should know commands and options that control those pairs.

The following table lists the UR pair operations and provides the corresponding CCI commands.

Operation

Options

In HDvM - SN?

CCI command and options

Create UR Pairs

Copy Type (VSP 5000 series)

Yes

paircreate

None

LU Selection

Yes

paircreate1

None

Base Secondary Volume

Yes

paircreate2

None

Mirror Selection

Yes

paircreate1

None

CTG ID

Yes

paircreate

-f[g] fence [CTG ID]

Initial Copy Type

Yes

paircreate

[-nocopy | -nocsus]

Initial Copy Priority

Yes

paircreate

None

Error Level

Yes

None

Split Pairs

Secondary Volume Write

Yes

pairsplit

-rw

Split Mirrors

Secondary Volume Write

Yes

None

Split Mode

Yes

pairsplit

[-P]

Resync Pairs

Copy Priority

Yes

pairresync

None

Error Level

Yes

pairresync

-nomsg

Resync Mirrors

None

Yes

None

Delete Pairs

None

Yes

pairsplit

-S

Delete Mirrors

Delete Mode

Yes

None

Switch host control3

None

No

pairsplit

-R[-S|B]

Notes:

  1. The LU and Mirror options cannot be specified with the paircreate command. Instead, you must specify them in the configuration definition file, in advance, and then run the pair create command.
  2. The Base Secondary volume and the Secondary volumes options cannot be specified with the paircreate command. Instead, you must specify them in the configuration definition file, in advance, and then run the pair create command.
  3. Switches the control from the primary site host to the secondary site host.

Monitoring operations

The following table lists the UR monitoring operations and provides the corresponding CCI commands.

Operation

Options

In HDvM - SN?

CCI command and options

View Pair Properties

None

Yes

pairdisplay

-m mode

View Pair Synchronization Rate

None

Yes

pairdisplay

-fc

View Remote Connection Properties

None

Yes

pairdisplay

-m mode

Maintenance operations

The following table lists the UR maintenance operations and provides the corresponding CCI commands.

Operation

Options

In HDvM - SN?

CCI command and options

Edit Pair Options

Error Level

Yes

pairresync

None

Force Delete Pairs (UR Pairs)

None

Yes

None

Edit Journal Options

None

Yes

raidcom modify journal

None

Edit Mirror Options

None

Yes

None

Assign Journal Volumes

None

Yes

raidcom add journal

-journal_id journal ID#

Delete Journals

None

Yes

raidcom delete journal

-journal_id journal ID#

Edit Remote Connection Options

RIO MIH Time

Yes

raidcom modify rcu

-rcu_option

Add Remote Paths

None

Yes

raidcom add rcu_path

None

Remove Remote Paths

None

Yes

raidcom delete rcu_path

None

Remove Remote Connections

None

Yes

raidcom delete rcu

None

Assign Remote Command Devices

None

Yes

None

Release Remote Command Devices

None

Yes

None

Parameter range for CCI options

The following table shows the range of parameters that can be set for CCI options. For details about CCI commands, see the Command Control Interface Command Reference.

Parameter

Range

Mirror ID (MU#)

0 to 3

CTG ID

  • VSP E590, VSP E790, VSP F350, VSP F370, VSP F700, VSP G350, VSP G370, VSP G700: 0 to 127
  • VSP E990, VSP F900, VSP G900, VSP 5000 series: 0 to 255

Journal ID

  • VSP E590, VSP E790, VSP F350, VSP F370, VSP F700, VSP G350, VSP G370, VSP G700: 0 to 255
    • For VSP E590, VSP E790, VSP G/F370, VSP G/F700, 256 journal IDs are available, but you can use only 128 of those IDs.
    • For VSP G/F350, 256 journal IDs are available, but you can use only 32 of those IDs. If shared memory "Extension1" is implemented, you can use up to 128.
  • VSP E990, VSP F900, VSP G900, VSP 5000 series: 0 to 255

Path group ID

  • VSP F350, VSP F370, VSP F700, VSP F900, VSP G350, VSP G370, VSP G700, VSP G900, VSP E series: 0 to 255
  • VSP 5000 series: 0 to 63

Consistency group operations

The following table lists the UR consistency group operations and provides the corresponding CCI commands.

Operation

In HDvM - SN

CCI command and options

Create or add pairs to the CTG

Yes

paircreate

-f[g] fence[CTG ID]

Split pairs in the CTG (no reservation time)

No

pairsplit

-S

Resync pairs in the CTG

No

pairresync

-f[g] fence[CTG ID]

Delete pairs in the CTG

No

pairsplit

-S

Switch the control from the primary site host to the secondary site host

No

pairsplit