Troubleshooting data export

Troubleshooting for Export Tool operations involves identifying the cause of the error and resolving the problem.

Troubleshooting Export Tool for Performance Monitor

The following table explains possible problems with Export Tool and probable solutions to the problems.

Possible problems

Probable causes and recommended action

You cannot run the batch file.

The path to the Java Virtual Machine (Java.exe) might not be defined in the PATH environment variable. If this is true, you must add that path to the PATH environment variable. For information about how to add a path to the environment variable, see the documentation for your operating system.

An incorrect version of Java Runtime Environment (JRE) might be installed on your computer. To check the JRE version, enter the following command at the Windows command prompt or the UNIX console window:

Java -version

If the version is incorrect, install the correct version of JRE.

Export Tool stops and the processing does not continue.

  • The command prompt window might be in pause mode. The command prompt window will be in pause mode if you click the command prompt window when Export Tool is running. To cancel pause mode, activate the command prompt window and then press the <ESC> key. If a timeout of RMI occurs during pause mode, the login will be canceled and an error will occur when you cancel pause mode after the timeout. The error message ID will be (0001 4011).
  • If a memory size is not specified in a batch file, the Out Of Memory Error occurs in JRE, Export Tool might stop and the processing might not continue. Confirm whether the specified memory size is correct or not.

The command prompt window was displaying progress of the export processing, but the window stopped displaying progress before the processing stopped. The progress information does not seem to be updated anymore.

An error occurs and the processing stops.

If the error message ID is (0001 4011), the user is forcibly logged off and the processing stops because Export Tool did not issue any request to SVP within the timeout period specified by the -Dmd.rmitimeout parameter of the Java command (default: 20 minutes). The computer running Export Tool could be slow. Confirm whether you are using a computer that is not supported, or whether the computer is slow. To continue running Export Tool, first increase the value of the -Dmd.rmitimeout parameter (maximum: 1,440 minutes (24 hours), and then run Export Tool. For details about -Dmd.rmitimeout, see the Operands table for the Java command in Operands. If the error persists, contact the customer support.

If the error message ID is (0002 5510), probable error causes and solutions are:

  • An internal processing is being performed in the storage system. Alternatively, another user is changing configurations. Wait for a while and then run Export Tool again.
  • Maintenance operations are being performed on the storage system. Wait until the maintenance operations finish and then run Export Tool again.

If the error message ID is none of the above, see Messages issued by Export Tool.

The monitoring data in the CSV file includes (-1).

For details on invalid monitoring data, see Causes of invalid monitoring data.

  • When Export Tool terminated abnormally due to error, the row of Check License is shown as Unmarshal Exception in the log file.
  • Export Tool terminated abnormally because the processing did not continue. version unmatched is shown in the log file.

(VSP G1x00 and VSP F1500) It might be an unsuitable combination of the DKCMAIN/SVP program version and the Export Tool version. Confirm whether versions of these programs are correct.

(VSP Gx00 models and VSP Fx00 models) It might be an unsuitable combination of the DKCMAIN firmware version, the Device Manager - Storage Navigator software version, and the Export Tool version. Confirm whether versions of these programs are correct.

Export Tool terminated abnormally. NoSuchObjectException is shown in the log file.

The computer workload might be high. Perform potential fixes to lower the workload as shown below. Then execute Export Tool again.

  • Reduce the number of Export Tool applications running concurrently.
  • Execute Export Tool while virus scan is not being performed by anti-virus software.

When a CSV file is opened, the parity group ID and volume ID appear as follows:

  • The parity group IDs appear as dates.
  • The volume IDs appear with a decimal point.

To display a CSV file correctly, you need to perform the following operations:

1. Start Microsoft Excel.

2. On the menu bar, select Data, Import External Data, and Import Text File, and specify a CSV file to import. The Text Import.zip - Step 1 of 3 dialog box is displayed.

3. In the Text Import.zip - Step 1 of 3 dialog box, click Next. Text Import.zip - Step 2 of 3 dialog box is displayed.

4. In the Text Import.zip - Step 2 of 3 dialog box, check only Comma in the Delimiter area, and click Next. The Text Import.zip - Step 3 of 3 dialog box is displayed.

5. In the Text Import.zip - Step 3 of 3 dialog box, select all columns of Date preview, and check Text in the Column data format area on the upper right of this dialog box.

6. Click Finish. The imported CSV file is displayed.

When you run Export Tool with many volumes specified, Export Tool terminated abnormally while collecting monitoring data.

Because too many volumes are specified, a timeout error might have occurred due to a heavy workload imposed on the computer where Export Tool was running. The error message ID is (0001 4011). Specify fewer volumes. It is recommended that the number of volumes to be specified is 16,384 or less.

When you switch the master and the standby SVP for the SVP in which SVP High Availability Feature is installed, short-range monitoring data disappears. (VSP G1x00 and VSP F1500)

When you switch the master and the standby SVP for the SVP in which SVP High Availability Feature is installed, only the long-range monitoring data is kept. When you switch the SVP, run Export Tool beforehand as necessary, and acquire the short-range monitoring data.

"404 Not found." or other errors appear when you run Export Tool.

This error occurred because the Export Tool execution has failed. Possible causes are as follows:

  • The svpip value is wrong.
  • The SVP version you are using is old.

"Specified "ip" is wrong." appears when you run Export Tool. (VSP Gx00 models and VSP Fx00 models)

This error occurred because the network connection with the SVP could not established. Possible causes are as follows:

  • The IP address or host name specified by the ip subcommand is incorrect.
  • The connection port number (default is 1099) specified by the ip subcommand is incorrect.*
  • The connection port number (default is 1099) for RMI connection used by the SVP is changed or used by other applications.*
  • The SVP is not working correctly or does not have a network connection.

* For the connection port number, see the hardware reference guide for your model.

Messages issued by Export Tool

If an error occurs when running Export Tool, error messages are issued to the standard output (for example, the command prompt) and the log file. The following table lists Export Tool messages, descriptions and recommended actions against errors.

Export Tool messages

Description

Recommended action

Connection to the server has not been established.

Connection to the server has not been established.

Use the login subcommand.

Execution stops.

Processing was stopped.

Remove errors.

Illegal character: character

An illegal character is used.

Use legal characters.

Invalid length: token

The length is invalid.

Specify a value that has a correct length.

Invalid Mode: startup-mode

Operation has failed due to invalid mode.

Specify a correct mode.

Invalid range: range

The specified range is invalid.

Specify the correct range.

Invalid URL: URL

The specified URL is invalid.

Check the URL.

Invalid value: value

The specified value is invalid.

Specify a correct value.

Login failed

An attempt to log on to the storage system or SVP failed. Probable causes are:

1. An incorrect operand is used for the following subcommands:

  • (VSP G1x00 and VSP F1500) svpip
  • (VSP Gx00 models and VSP Fx00 models) ip
  • (VSP Gx00 models and VSP Fx00 models) dkcsn

2. An incorrect operand is used for the login subcommand.

3. The specified user ID is used by another user, and the user is logging in to the storage system or SVP.

4. Another user is using the Server Priority Manager window.

5. Another user is running Export Tool.

6. (VSP G1x00 and VSP F1500) The combination of DKCMAIN/SVP and Export Tool is invalid.

7. (VSP Gx00 models and VSP Fx00 models) Versions of Device Manager - Storage Navigator and Export Tool do not match.

If the error is not caused by the conditions listed above, see Troubleshooting Export Tool for Performance Monitor.

For 1 and 2, specify the correct operand.

For 3, determine the user logging in with same user ID and ask the user to log off.

For 4 and 5, take one of the following actions:

  • Ask the other user to close the Server Priority Manager window.
  • Ask the other user to log off.
  • Wait for the other user to quit Export Tool.

(VSP G1x00 and VSP F1500) For 6, use the correct combination of versions for DKCMAIN/SVP and Export Tool.

(VSP Gx00 models and VSP Fx00 models) For 7, match the versions of Device Manager - Storage Navigator and Export Tool.

Missing command file

The command file is not specified.

Specify the name of the command file correctly.

Missing group name

No operand is specified in the group subcommand.

Specify operands for the subcommand.

Missing host name

No host name is specified.

Specify a host name.

Missing output directory

No directory is specified for saving files.

Specify the directory for saving files.

Missing password

Export Tool cannot find the user password, which is used to log on to the storage system.

Specify the password.

Missing svpip (VSP G1x00 and VSP F1500)

The svpip subcommand is not used.

Use the svpip command.

Missing ip (VSP Gx00 models and VSP Fx00 models)

The ip subcommand is not specified.

Specify the ip subcommand first.

Missing dkcsn (VSP Gx00 models and VSP Fx00 models)

The dkcsn subcommand is not specified.

Specify the dkcsn subcommand first.

Missing time range

The time range is not specified.

Specify the time range.

Missing user ID

Export Tool cannot find the user ID, which is used to log on to the storage system.

Specify the user ID.

Out of range: range

The value is outside the range.

If the shortrange subcommand or the longrange subcommand is used, specify a value within the range from the monitoring start time to the monitoring end time. For specification required when you narrow down the file save period with a longrange subcommand, see longrange (VSP G1x00 and VSP F1500).

If the set subcommand is used with the switch operand, specify a value within the range of 1 to 15.

Permission Denied

The user ID does not have the required permission.

Assign the applicable storage administrator’s role (performance management) to the user ID.

RMI server error (part-code, error-number)

An error occurs at the RMI server.

See the Hitachi Device Manager - Storage Navigator Messages.

Serial-No not found (VSP Gx00 models and VSP Fx00 models)

The serial number of the system in which to obtain monitoring data cannot be found.

Specify the serial number of the system connected to the SVP.

Same log path: path

Same path is specified for el.logpath and el.logfile parameters, or md.logpath and md.logfile parameters.

Check the path you have specified.

Unable to display help message

Export Tool cannot display the online help due to a system error.

Run Export Tool again. If the problem occurs again, contact customer support.

Unable to execute ExportTool.

Failed to run Export Tool.

The downloaded file is damaged or an error might have occured while running Export Tool.

Run Export Tool again. If the problem occurs again, contact customer support.

Unable to get ExportTool from the server : URL=URL [,code=error-code]

Failed to obtain Export Tool from the server. HTTP might have failed to obtain the file.

Check the URL and the HTTP error codes. No error code is displayed for errors that occur while data is being obtained.

Unable to get serial number

Export Tool cannot obtain the serial number due to a system error.

Check the following:

- SVP is operating correctly.

- SVP is connected to the network.

Unable to get time range for monitoring

SVP does not contain monitoring data.

Accumulate monitoring data before using Export Tool.

Unable to read command file: file

Export Tool cannot read the command file.

Specify the name of the command file correctly.

Unknown host: host-name

Export Tool cannot resolve the host name.

Specify the correct host name.

Unsupported command: command

Export Tool does not support the specified command.

Specify a correct command.

Unsupported operand: operand

The specified operand is not supported.

Correct the specified operand.

Unsupported option: option

The specified option is not supported.

Correct the specified option.

Some file exists in path. What do you do? clear(c)/update(u)/stop(p) You selected "action". Is it OK? (y/n)

Files exist in path.

If you want to clear the files, press the <c> key.

If you want to overwrite the files, press the <u> key.

If you want to stop the operation, press the <p> key.

When you press a key, a message appears and asks whether to perform the specified action.

To perform the specified action, press the <y> key.

To cancel the specified action, press the <n> key.

Specified "ip" is wrong. (VSP Gx00 models and VSP Fx00 models)

The IP address, the host name, or the connection port number is not correct.

Check the IP address, host name, or connection port number of the SVP. If you do not specify the connection port number, 1099 (default) is used. If the probable cause is not applicable, see Troubleshooting Export Tool for Performance Monitor

Specify the following subcommand before login subcommand: retry

The retry subcommand is written in an incorrect position in the command file.

Write the retry subcommand before the login subcommand.

Syntax error: line

A syntax error is detected in a command line in your command file.

Check the command line for the syntax error and then correct the script.

Some operands must be enclosed by double quotation marks ("). Check the command line to find whether double quotation marks are missing.

Unable to connect to the server : host:port

Failed to access the server.

Check the hostname and port number.

Unable to create temporary directory: tmp

Failed to create a temporary directory.

Check the access permission to the directory, and make sure if there are any files.

[login]version unmatched (VSP Gx00 models and VSP Fx00 models)

The Export Tool version does not correspond to the Device Manager - Storage Navigator software version.

Upgrade Export Tool to match the Export Tool and Device Manager - Storage Navigator. software versions.