Hitachi Unified Compute Platform (UCP) Advisor 2.0 Patch 1 Release Notes

About this document

This document (RN-92UCP099, October 2017) provides late-breaking information about Unified Compute Platform (UCP) Advisor 2.0.0 Patch 1. It includes information that was not available at the time the technical documentation for this product was published, as well as a list of known problems and solutions.

Intended audience

This document is intended for customers and Hitachi Vantara partners who license and use Unified Compute Platform (UCP) Advisor.

About this release

This release includes minor enhancements.

New features and enhancements

·         UCP advisor now has the ability to onboard more than 25 servers at a time.

·         Support of JDK 8U51 update for Java bug fixes and security enhancement.

Supported hardware

Compute

The UCP Advisor compute hardware and firmware requirements are identified, as follows:

Model

Firmware

DS120
(D52B-1U1N)

BIOS

3A08.H2

BMC

3.16.06_HDS

D51B-2U1N

BIOS

S2B_3B09.01

BMC

3.52.00

T41S-2U4N

BIOS

S2S_3B08.02

BMC

3.52.00

Ethernet Switch

The UCP Advisor Ethernet switch models and firmware requirements are identified, as follows:

Model

Firmware

Cisco Nexus 93180YC-EX NX-OS version

7.0(3)I4(6)

Cisco Nexus 93180LC-EX NX-OS version

7.0(3)I7(1)

Cisco Nexus 9372PX NV-OS version

7.0.(3)I2(4)

Cisco Nexus 9332PQ NX-OS version

7.0.(3)I2(4)

Brocade VDX 6740

v7.0.0a

Brocade VDX 6940

v7.0.0a

Ethernet Switch (management)

Model

Firmware

Cisco Nexus 3048 NX-OS Version

7.0(3)I4(6)

Brocade ICX 7450

08040

Quanta T1048 LB9

Cumulus Linux 2.5.8

Fibre Channel Switch

The UCP Advisor Fibre Channel switch models and firmware requirements
are identified, as follows:

Model

Firmware

Brocade G620

v8.0.1

Brocade 6505

V7.4.1d

Brocade 6510

V7.4.1d

Storage

The UCP Advisor storage models and microcode requirements are identified, as follows:

Model

Microcode1

VSP G200

83-04-26-20/00

VSP G400

83-04-26-40/00

VSP G600

83-04-26-40/00

VSP G800

83-04-26-60/00

VSP G1500

80-05-01-00/00

VSP F400

83-04-26-40/00

VSP F600

83-04-26-40/00

VSP F800

83-04-26-60/00

VSP F1500

80-05-01-00/00

1. The listed microcode versions are the minimum versions.

Supported software

The UCP Advisor environment can include the following software programs. Prior to deploying UCP Advisor, verify that the required software is installed and configured.

VMware

Component

Version

ESXi

6.5 U1 (Build 5969303)

vCSA

6.5 U1 (Build 5973321)

VMware Tools

10.1.7.5541682

VMware PowerCLI

6.5.2.6268016

vSAN

6.6.1

vRealize Orchestrator (vRO)

7.3

vRealize Log Insight (vRLI)

4.5

Hitachi Vantara

Hitachi Vantara

Version

UCP Advisor Controller

2.0.0.1528

UCP Advisor Gateway

5.2.0.2971

Hitachi Automation Director

8.5.3

HiTrack

8.0 or greater

Other software

Software

Version

Java

8u151 (64-bit)

Python

2.7.6 (64-bit)

Redis

3.0.503

OpenSSH

7.5.1

Known issues

Defect ID

Problem

Workaround

159

Two Toolbox items show up in "Files in use" window during uninstallation.

There is no difference between the two items.
Choose either Toolbox item.

309

You can onboard host names or IP addresses. However, there is no capability to convert or compare IP addresses to host names with vCenter.

For example, if the host is registered in vCenter using its host name, and the node is on-boarded with its IP address, some features, such as vSAN drives,  do not display any information.

Use the IP address.

464

All tabs under Administration fail to load after the system is left idle.

This issue occurs after adding servers and navigating to the Servers tab, then leaving the UI idle.

Upon returning to the Administration section, all of the tabs such as Configuration, Compute, Storage, Network, Backup, Log Bundle fails to load and displays errors such as, "Loading configuration failed" or  "Loading Compute failed" with no data shown in the windows.

This is a session ID timeout issue. The session timeout occurs after 25 minutes.

Navigate back from vCenter Home > UCP Advisor icon, select an appliance, and access the Administration tab or navigate further.

553

vSAN: Refresh doesn't work after a host is disconnected.

1. Create a vSAN and check for its fields in the UCP Advisor UI.

2. Disconnect one of the hosts in the vSAN cluster.

3. In the vCenter UI, all disk information goes blank and the status of the host is disconnected.

4. In the UCP Advisor UI, the status remains the same even after multiple refreshes. The disks also continue to appear in the vSAN inventory screen.

Navigate back from vCenter Home > UCP Advisor icon. Select a UCP Appliance and navigate further.

649

Provisioning datastore to cluster fails.

Create a host group and add WWNs for both hosts in the host group.

1. Go to Storage > DataStore > Provision a DataStore and select both hosts.

2. Create DataStore task failed.

Verify that there is only one host per host group.

657

The confirmation window will not close after the power operation fails, due to the same power state.

This occurs while attempting to perform the same power operation that the server state is already in (for example, power ON while the server is already ON). Even after the operation fails, the confirmation box remains open.

Close the confirmation window by selecting the close button or the X icon on the window.

720

UI displays error message 'Loading <Resource> failed" for all storage resources

UI can fail to load storage resources such as logical units or host groups right after performing tasks to create these resources, or after a refresh of the storage system. 

Navigate back from vCenter Home > UCP Advisor icon. Select a UCP Appliance, access the storage resource, and attempt loading the storage resources.

746

ESXi deployment issue: Datacenter name is missing from the Summary window and deployment is performed to the wrong datacenter with duplicate cluster name.

In the Summary window of vCenter Hosts and Clusters, the datacenter name is not displayed. However, this information is displayed after the deployment is completed. Since the UI does not display the datacenter name, in the case of two clusters with the same name in two datacenters, the host is deployed to a wrong datacenter cluster.

Make sure you don't have two clusters with the same name in different datacenters. If necessary, rename the datacenter.

791

Error message "Onboarding Storage failed" is displayed due to a missing command device.

Message: "Error occurred while adding storage. Error occurred while connection to storage device 56227. Server internal error: missing configuration info for storage id: 56227" is displayed when adding a storage resource. The command device on the UCP Gateway host is unavailable.

Provision a storage array command device and present it to the UCP Gateway VM host.

835

All device-related operations do not work with host name/FQDN.

Use the host IP address instead.

855

Upgrading Brocade G620 and Cisco switches can fail due to SSH host keys.

Upgrading Cisco 3048, 93180YC, 93180LC, and Brocade G620 switches can fail if the SCP server host key changes. This is expected and is a security design.

Clear the SSH host keys on the Cisco and Brocade switches.

To clear Cisco 93180YC and 93180LC switches:

R1-93180LC-EX-B# clear ssh hosts

To clear Brocade FC G620 switches:

R1-G620-A: admin> sshutil delknownhost -all

This command deletes all the known host keys.

Please confirm with Yes (Y,y), No (N,n) [N]: y

All known hosts are deleted successfully.

869

The create command device operation can fail from Toolbox when the proxy settings are enabled.

Enable bypass proxy server for the local addresses option in the proxy settings.

872

Unable to download files through the Swagger UI.

Downloaded files appear corrupted when they are downloaded from Swagger UI.

Use an https call in a browser, use postman client, or other methods to download files.

This is a known Swagger issue:

https://github.com/swagger-api/
swagger-ui/issues/1605

876

vRO Storage workflows: Storage systems do not appear in the menu for selection.

The added storage is not listed in the HitachiStorageConnector list.

1) Add the storage device using a vRO workflow.

2) Open the workflow Create LU in dynamic Pool and try selecting the added storage in the Hitachi storage array field.

Use the Filter tab to identify and select the storage system, or use the vRO web client.

882

Swagger UI cannot handle very large files.

The

UndefinedNameError: reference to undefined name 'UploadFirmwareBundle' (click for details)
Callstack:
    at (Documents/Converged/UCP_Advisor/2.0/Release_Notes/Hitachi_Unified_Compute_Platform_(UCP)_Advisor_2.0_Patch_1_Release_Notes), /content/body/div/div[7]/table/tr[16]/td[2]/p[2]/span[2]/code/span, line 1, column 1
REST API call cannot be executed through the Swagger UI because the firmware bundle is large (file size is greater than 3.5 GB).

The Swagger UI returns a no content response, and the operation is not executed.

Use a curl command to execute this API.

893

Edit Zone removes existing WWN member if it is not in any alias.

In the UCP Advisor UI, for creating or editing a zone, it accepts only alias name and not WWN directly.

But in the switch CLI, the user can create a zone with WWN as well.

Consider that the zone has WWN as a member and not the alias. When you select that zone and click Edit Zone, the WWN is not listed in the list of members.

When you make any changes like selecting a new alias name and click Submit, the existing WWN is removed automatically.

Create an alias first, and then create or edit the zone. Do not create a zone with WWN via the switch CLI.

915

Replace Host: The host is placed in an incorrect data center when two clusters with same name exist in different datacenters.

If two clusters with same name exist in two data centers and Replace Host operation is attempted for a host in one of those clusters, the replacement host is placed in a different cluster.

Make sure that no two clusters have the same name in different data centers. If necessary, rename the data center.

926

Sync VLAN UI may only show one port for sync but backend syncs both switches

UI will only show 1 of 2 VM NICs for server being synchronized. However, the backend code will synchronize both VM NICs with the switch.

Check vCenter task to confirm both switches are synchronized with VLAN configuration.

928

Upgrading BIOS will reset the boot order.

Boot order set to SATADOM over PXEboot is reset when UCP Advisor performs a BIOS upgrade.

Reboot the server, login to the console, and manually set the boot order.

929

Replace host workflow fails to remove host from vCenter if host is part of vDS.

Replace host workflow fails at the very end if host is part of a vDS.

Remove the host from vDS and then try removing it from vCenter.

950

If the UCP Appliance instance already exists, you can't create a new UCP Appliance with the same name.

1. Create a single UCP Appliance instance.

2. Stop the UCP Advisor web service.

3. Use the vCenter plugin to delete the UCP Appliance.

4. Start the UCP Advisor web service.

5. Create new UCP Appliance instance with the same name. An error indicating existence of a duplicate UCP Appliance appears.

Use the REST API command to delete the UCP Appliance, and then use the UCP Advisor GUI to create the UCP Appliance instance with the same name.

957

Set boot option does not change the server BIOS Boot Option #1.

Change the boot option in BIOS.

984

UI crashes when multiple appliances are created or when multiple sessions are active.

After multiple UCP Appliances are created or when multiple users access the same vCenter, the server windows fail to load information or show errors:

1. Individual managed objects fail to load.

2. Incorrect server count is shown: 0 in most places.

3. Permission denied errors are displayed.

Navigate out of UCP Advisor and then navigate back in.

987

In Create Zone window, clicking on any unselected alias (not the checkbox) unselects an existing selected alias

1. Click Create Zone and enter the zone name.

2. Click on any new alias in the Alias Name field to select it.

3. Click on a different alias.

The previously selected alias is unselected.

Use the checkbox to select an alias.

1013

Syslog agent does not forward compute device logs after the Windows service is restarted.

Restart the UCP Advisor Windows service after the Syslog agent Windows service is restarted.

1033

Brocade ICX7450 (UCP2000 Management) switch has 28 ports, only 27 ports are displayed in the switch diagram. The missing port is 1/1/22.

Contact Customer Support.

1057

ucp-advisor-sidecar is not restarting after a crash.

1. Find the Process IDs for Local Address containing port 23016.

C:\Windows\system32>netstat -a -n -o | findstr :23016

  TCP    0.0.0.0:23016          0.0.0.0:0              LISTENING       3456

  TCP    [::]:23016             [::]:0                 LISTENING       3456

2. Stop all processes with the following PID:

C:\Windows\system32>TaskKill.exe /F /PID 3456

SUCCESS: The process with PID 3456 has been terminated.

3. Wait for 2 minutes and verify that ucp-advisor-sidecar is RUNNING.

Accessing documentation

This section lists the Infrastructure Analytics Advisor user documentation. Product documentation is available on Support Connect: https://knowledge.hitachivantara.com/Documents/Converged/UCP_Advisor/1.2. Check this site for the most current documentation, including important updates that may have been made after the release of the product.

Document name

Document number

Hitachi Unified Compute Platform (UCP) Advisor Administration Guide

MK-92UCP102

Hitachi Unified Compute Platform (UCP) Advisor Pre-Installation Requirements and Configuration Guide

MK-92UCP104

Copyrights and licenses