Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

Hitachi Content Intelligence v2.2.3 Release Notes

 

About this document

 

This document provides information about Hitachi Content Intelligence (HCI) software release v2.2.3.5, including new features, important enhancements, product requirements, as well as fixed and known issues.

Intended audience

 

This document is intended for system administrators, Hitachi Vantara representatives, and authorized service providers who configure and operate the HCI software.

About this release

 

The v2.2.3.5 release of HCI features bug fixes and security improvements.

Major features

 

General updates

 
Bug fixes and security improvements

This release of HCI resolves two product bugs, from which security improvements were implemented. For more information, see Resolved issues.

Resolved issues

 

Issue

Area affected

Description

Outcome
HCI-9604 Admin App, Security Active Directory does not authenticate correctly when using HTTP Negotiate. Authentication issues while using HTTP Negotiate no longer occur.
HCI-9611 Admin App, Security Email notifications are unable to be sent due to an issue with SMTP encryption settings. The supported TLS versions have been updated and the error no longer occurs.

Known issues

 

Issue

Area affected

Description

Outcome/Workaround
HCI-286 Workflow Designer App Using Retry Failed Documents manually in a workflow that has failures doesn't add to the output metrics after it has successfully indexed those files. The results of the Retry Failed Documents setting do not affect output metrics and the files are still indexed successfully.
HCI-353 Job Driver When attempting to migrate data to a namespace that has already hit its hard quota, 413 errors are received without any failure notifications in the workflow. The failures are instead reported in the advanced historic metrics. N/A
HCI-1047 Content Monitor App Replication links with forward slashes (/) do not appear in the Replication metrics. Replace the forward slashes in the Replication link name with any other ASCII character (space, %, etc.).
HCI-1737 Workflow Designer Enabling Process all documents ignores the HCP and Sharepoint connector's directories when a workflow is resumed. N/A
HCI-1918 Metrics Metrics service cannot be scaled to twice the current number of instances.
  • Scale the instances back down to the original instances.
  • Wait for the scale action to complete.
  • Scale the instances back up to the desired number of instances.
HCI-6103 Workflow Designer App

On a multi-node cluster, if one of the nodes goes down, the workflow halts with a task error. The task error states that the driver heap limit is too low for the workflow, but raising this value in the workflow settings does not restart the workflow.

The workflow-agent job type is configured to run on all nodes in a cluster by default. Scaling the workflow-agent off of the bad node will allow workflows to resume.

HCI-6109 Admin App HCI enters a bad state after rebooting 2 of the 3 master nodes available on a 4-node cluster. Reboot all HCI master nodes at the same time and the clusters will return normally.
HCI-6128 Metrics Metrics from historical logs are ignored after an update and present an OOM message.

If you notice your imported logs missing after update, reimport them and the metrics will display correctly.

HCI-6304 Workflow Designer App Testing a data connection accessible by proxy shows a blank certificate and cancelling it makes the system seem unresponsive.

If your data connection can only be accessed by proxy and requires a certificate, download the certificate from the other system and manually add it to the Admin App

To do this, navigate to Configuration > Certificates > Client and click UPLOAD CLIENT CERTIFICATE.

HCI-6540 Solr During an update, Solr shards appear in the Gone state if Marathon references the old port number and node name pairing when starting the Solr service.

Delete the Gone shards:

  1. Navigate to the Solr UI.
  2. Click Collections.
  3. For each affected index:
    1. Click the index name.
    2. Click the affected shards.
    3. Click X.
    4. Confirm the deletion.
HCI-6857 Search App Search App exclusive users with bulk action permissions are able to see Workflow Designer as an option in their SSO menu. Clicking it presents a message telling the user the page cannot be displayed. N/A
HCI-7020 Admin App When updating from HCI 1.6.x to 1.10.1, the doc folder is owned by root on several nodes in the cluster, causing an update failure. Changing the user from root to hci and retrying the failure resolves the issue.
HCI-7341 Solr When attempting to recreate a delete Solr collection with a different initial schema, the old schema is still present in the UI. This is an internal HCI ticket to track the progress of SOLR-15674, which was filed directly with Apache. N/A
HCI-7366 Search App The autocomplete functionality of the search bar in Search App does not work for file names in Chinese after reindexing text field changes. N/A
HCI-7368 Solr If an index is created without using a SolrCloud connection URL, attempts to create bulk actions using the index will fail. N/A
HCI-7369 Solr When attempting to remove a copy field from an index, the delete fails with a "Collection not found" error and the index is unable to be written to. N/A
HCI-7370 Solr Solr can only use comparatives with small numbers and returns 0 results (in error) when using larger ones. N/A
HCI-8242 Import Importing a Solr alias bundle containing an index associated with HCP for Cloud Scale Bucket Indexing results in an error.
  1. Import the HCP for Cloud Scale Bucket Indexing bundle.
  2. Reload the imported bundle.
  3. Import the Solr alias bundle.
HCI-8243 Import After importing specific components from a bundle, an error message is received when attempting to add additional components. Import the bundle in its entirety. If the error persists, contact your Hitachi Vantara representative.

System requirements

 

This section lists the hardware, networking, and operating system requirements for running an HCI system with one or more instances.

Hardware requirements

 

This table shows the minimum and recommended hardware requirements for each instance in an HCI running Hitachi Content Search.

Resource

Minimum

Recommended

RAM

16 GB

32 GB

CPU

4-core

8-core

Available disk space

50 GB

500 GB

Software requirements

 

The following table shows the minimum requirements and best-practice software configurations for each instance in an HCI system.

Resource Minimum Best
IP addresses (1) static (2) static
Firewall Port Access Port 443 for SSL traffic

Port 8000 for System Management App GUI

Port 8888 for Content Search App GUI

Same
Network Time IP address of time service (NTP) Same

Operating system and Docker minimum requirements

 

Each server or virtual machine you provide must have the following:

  • A 64-bit Linux distribution
  • Docker version 1.13.1 or later installed
  • IP and DNS addresses configured

Additionally, you should install all relevant patches on the operating system and perform appropriate security hardening tasks.

Important
  • Install the current Docker version suggested by your operating system, unless that version is earlier than 1.13.1. The system cannot run with Docker versions prior to 1.13.1.
  • HCI will not function on an operating system that uses cgroups v2. If your system currently utilizes it, you must downgrade to cgroups v1 prior to installation.

Operating system and Docker-qualified versions

 

This table shows the operating systems, as well as the Docker and SELinux configurations, on which this HCI release was qualified. It acts a point of reference for our customers to better share how we operate within our internal environment and does not represent any requirements that need to be followed within your own.

Operating system Docker version Docker storage configuration SELinux setting
CentOS 8.1 Docker 19.03.13 overlay2 Enforcing
Red Hat Enterprise Linux 8.1 Docker 20.10.14 overlay2 Enforcing
Ubuntu 18.04.4 LTS Docker 18.03.1-ce overlay2 Not Installed

Docker considerations

 

The Docker installation folder on each instance must have at least 20 GB available for storing the HCI Docker images.

Make sure that the Docker storage driver is configured correctly on each instance before installing HCI. To view the current Docker storage driver on an instance, run docker info.

NoteAfter installing, changing the Docker storage driver requires a reinstallation of HCI.

If you are using the Docker devicemapper storage driver:

  • Make sure that there's at least 40 GB of Docker metadata storage space available on each instance. HCI needs 20 GB to install successfully and an additional 20 GB to successfully update to a later version. To view Docker metadata storage usage on an instance, run docker info.
  • On a production system, do not run devicemapper in loop-lvm mode. This can cause slow performance or, on certain Linux distributions, HCI might not have enough space to run.

SELinux considerations

 

You should decide whether you want to run SELinux on system instances and enable or disable it before installing HCI. To enable or disable SELinux on an instance, you must restart the instance. To view whether SELinux is enabled on an instance, run: sestatus

To enable SELinux on the system instances, use a Docker storage driver that supports it. The storage drivers that SELinux supports differ depending on the Linux distribution you're using. For more information, see the Docker documentation.

Time source requirements

 

If you are installing a multi-instance system, each instance should run NTP (network time protocol) and use the same external time source. For information, see support.ntp.org.

Supported browsers

 

The following browsers are qualified for use with HCI software. Other browsers or versions might also work.

  • Google Chrome (latest version as of the date of this publication)
  • Microsoft Edge (latest version as of the date of this publication)
  • Mozilla Firefox (latest version as of the date of this publication)

Documentation set

 

Along with your release notes, the following guides and documentation comprise the full set of HCI reference documentation:

  • Hitachi Content Intelligence Installing Hitachi Content Intelligence
  • Hitachi Content Intelligence (HCI) Getting Started Guide
  • Hitachi Content Intelligence Workflow Designer Help
  • Hitachi Content Intelligence Search Help
  • Hitachi Content Intelligence Content Monitor Help
  • Hitachi Content Intelligence Administrator Help

To learn more, visit the HCI Knowledge page.

 

  • Was this article helpful?