Objective
   - To collect logs from an Extreme 200 Series Switch for troubleshooting
  
    Environment
  - Content Platform
  - Extreme Networks
  
    Procedure
  - Connect serial cable (pinout varies by product) into console port.
  - Open PuTTY or another terminal emulator.
  - Set the serial connection settings to: 
 - 9600 bps 
  - no parity
  - 8 data bits
  - 1 stop bit
  - XON/XOFF flow control
Do not use hardware flow control. The switch does not use it and will never assert CTS.
  
   
  - Login using (default credentials provided below): 
 - user: admin
  - password: leave empty
  
   - Enter into Privilege EXEC mode
(Extreme 210)> enable
  - Disable CLI paging:
(Extreme 210)# terminal length 0
  - While in Privileged EXEC (enable) mode and having configured the terminal emulator for capture, issue the following command:
(Extreme 210)# show tech-support  
    Additional Notes
 Sources from Extreme Networks:
     
						
							Tags: HCP,HCP G10,Extreme Networks,Extreme 210,Extreme 220,Extreme 200
 PageID: 87380
 
						
				
					- Keywords
 
						- https://knowledge.hitachivantara.com/Support_Information/Data_Collection/Networking/How_to_Collect_Logs_from_Extreme_200_Series_Switch
 
					- Solution ID
 
					- 242403050087380
 
					- Last Modified Date
 
					- 09/07/2024 07:43:51 PM
 