| ShadowImage Data Collection |
Content | ShadowImage Data Collection RAID Subsystems The following procedures should be followed when collecting data for ShadowImage failures. They apply to 9900, 9900V, USP, NSC55, USP-V, USP-VM and VSP. Customer or CE - Supply the data described in the CCI Data Collection procedures (Open Systems only).
- Detail exactly what was happening when the dump was taken or the problem was occuring. For example, was there large SI Initial Copy or Resync activity being performed?
- Provide Graph-Track or Perfmon data if this is a performance problem.
- Provide the time difference between the clock on the SVP and real time.
CE - Turn on the SVP monitor.
- Turn on Mode 31.
- Perform AutoDump/detail.
- Turn off Mode 31.
DF Subsystems The following procedures should be followed when collecting data for ShadowImage failures. They apply to 9500V and AMS. Customer or CE - Supply the data described in the CCI Data Collection procedures.
- Detail exactly what was happening when the dump was taken or the problem was occuring. For example, was there large SI Initial Copy or Resync activity being performed?
- Provide a simple trace from the subsystem.
- Provide PFM data if this is a performance problem.
- Provide the time difference between the clock on the subsystem and real time.
|
CXone Metadata | Tags: Shadowimage,SI,Data collection,replication Page ID: 11958 |
|