VSP F400, F600 storage system specifications
The following table provides an overview of the system specifications for VSP F400, F600 storage systems.
Item | VSP F400, F600 specifications | |||
System | VSP F600 | VSP F400 | ||
Number of Flash Module Drives | Minimum | 4 | ||
Maximum | 288 | 192 | ||
Number of Flash Drives | Minimum | 4 | ||
Maximum | 576 | 384 | ||
RAID level | RAID1, RAID5, RAID6 | |||
RAID group configuration | RAID6 | 6D+2P, 14D+2P | ||
RAID5 | 3D+1P, 7D+1P | |||
RAID1 | 2D+2D, 4D+4D | |||
Maximum number of spare drives*1 | 32 | |||
Maximum number of LDEVs | 4,096 | |||
Maximum storage system capacity (physical capacity) | 4,053 TB (using 14 TB FMD) | 2,702 TB (using 14 TB FMD) | ||
2,178 TB (using 3.8 TB SSD) | 1,452 TB (using 3.8 TB SSD) | |||
Maximum external configuration | 16 PB | |||
Maximum number of DBs | 24 | 16 | ||
Memory | Cache memory capacity | 64 GB to 256 GB | 64 GB/128 GB | |
Cache memory capacity with NAS module is installed | 256 GB | 128 GB | ||
Cache flash memory | BM20/BM30 | |||
Storage I/F | DKC to Drive Interface | SAS/Dual Port | ||
Data Transfer Rate | 6Gbps/12Gbps | |||
Maximum number of drive per SAS I/F | 24 | |||
Maximum number of DKB PCB | 2 | |||
Device I/F | Support channel type | Open system | Fibre Channel Short Wavelength *2 / iSCSI*4 | |
NAS(NFS/CIFS) | ||||
Data transfer rate | Fibre Channel | 200/400/800/1,600/3,200 MB/s | ||
iSCSI | 100/1,000 MB/s | |||
NAS(NFS/CIFS) | 1,000 MB/s | |||
Maximum number of CHB | 8 (10:DKB Slot used) | |||
14*5 (16:DKB Slot used) | ||||
Maximum number of CHB with NAS module is installed | 6 | |||
Acoustic level*3 | Operating | CBL | 60dB | |
DBSC/DBF | 60dB | |||
Standby | CBL | 55dB | ||
DBSC/DBF | 55dB | |||
Non-stop maintenance | Control PCB | Supported | ||
Cache memory | Supported | |||
Cache flash memory | Supported | |||
Power supply, fan | Supported | |||
Microcode | Supported | |||
Flash Drive, Flash Module Drive | Supported | |||
Notes: *1: Available as spare or data drives. *2: The port can be changed to long wavelength by replacing the SFP transceiver of the fibre port on the CHB to the DKC-F810I-1PL8/1PL16. *3: Measurement Condition: The point 1m away from the floor and surface of the product. *4: Short wavelength model is DW-F800-2HS10S, copper model is DW-F800-2HS10B. *5: SVOS 6.3.1 or later |