Mechanical specifications for VSP F400, F600
The storage system mechanical specifications are described for VSP F400, F600 .
VSP F400 and VSP F600 mechanical specifications
Controller
Quantity | Component | Description |
1 | CBLM | A 4U controller chassis consisting of controllers, channel boards, disk boards, NAS module (optional), AC or DC power supplies, and batteries with cooling fans. |
Quantity | Component | Description |
1 | FMD tray |
A drive tray that supports flash module drives and consists of an ENC and AC-DC power supplies equipped with built-in cooling fans. |
Component | Description |
NAS module |
Optional component for block and file storage configuration |
Component | Specification |
Flash Module Drive (flash module drive tray) | 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm) |
Component | Specification |
Flash Module Drive (flash module drive tray) | 1759.21, 3518.43 , 7036.87, 14073.74 GB |
Component | Specification |
Maximum number of flash module drives (VSP Fx00 models) | VSP F400: 8 +1 spare drive
VSP F600 16 + 1 spare drive |
Storage system intake temperature | CBLM |
Up to 75.2º F (24º C) | 5 years |
Up to 86º F (30º C) | 5 years |
Up to 93.2º (34º C) | 4 years |
Up to 104º (40º C) | 3 years |
Item |
Component |
Specification |
Interface type |
Fibre Channel optical |
8-Gbps, 16-Gbps, 32-Gbps |
iSCSI optical |
10-Gbps | |
iSCSI copper |
10-Gbps | |
NAS module |
10-Gbps (Fibre Channel optical) | |
Data transfer speed (maximum speed for transfer to host) |
Fibre Channel optical |
800-Mbps (Fibre Channel) |
1600-Mbps (Fibre Channel) | ||
3200-Mbps (Fibre Channel) | ||
iSCSI optical |
10-Gbps (iSCSI optical) | |
iSCSI copper |
10-Gbps (iSCSI copper) | |
NAS module (Fibre Channel) |
1000 Mbs | |
Number of ports |
8-Gbps Fibre Channel optical | 64 |
16-Gbps Fibre Channel optical (2-port) | 32 | |
16-Gbps Fibre Channel optical (4-port) | 64 | |
32-Gbps Fibre Channel optical (4-port) | 64 | |
10-Gbps optical iSCSI | 32 | |
10-Gbps copper iSCSI | 32 | |
Number of ports (NAS Module not installed) |
8-Gbps Fibre Channel optical |
56 |
16-Gbps Fibre Channel optical (2-port) |
28 | |
16-Gbps Fibre Channel optical (4-port) |
56 | |
32-Gbps Fibre Channel optical (4-port) |
56 | |
10-Gbps optical iSCSI |
28 | |
10-Gbps copper iSCSI |
28 | |
Number of ports (NAS Module installed) |
8-Gbps Fibre Channel optical |
24 |
16-Gbps Fibre Channel optical (2-port) |
12 | |
16-Gbps Fibre Channel optical (4-port) |
24 | |
32-Gbps Fibre Channel optical (4-port) |
24 | |
10-Gbps optical iSCSI |
12 | |
10-Gbps copper iSCSI |
12 | |
10-Gbps Fibre Channel optical |
12 | |
Transferred block size |
512 bytes | |
Maximum number of hosts using a Fibre Channel switch |
255 | |
Maximum number of hosts using a network switch |
255 |
D: Data drive, P: Parity drive.
Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.
RAID Level |
SAS, SAS 7.2k, flash drives mounted |
RAID 1 |
2D+2D, 4D+4D |
RAID 5 |
3D+1P, 4D+1P, 6D+1P, 7D+1P |
RAID 6 |
6D+2P, 12D+2P, 14D+2P |
Item |
Specification |
Maximum number of RAID groups |
VSP F400:160 VSP F600:240 |
Maximum volume size |
3 TB (or 4 TB when using the LDEVs of other storage systems) |
Maximum volumes/host groups and iSCSI targets |
2048 |
Maximum number of volumes per RAID group |
2048 |
Shared memory and data assurance
Item | Specification |
Flash memory | 32 MB |
L3 Cache memory | 4 MB |
SDRAM | 1 GB |
Data bus | Parity |
Cache memory | ECC (1 bit for correction, 2 bits for detection) |
Drive | Data assurance code |
Start-up time
Item |
Standard: 5-to-8 minutes.
The start-up time may be longer in proportion to the number of drive trays connected. With a maximum configuration 1 controller tray and 19 drive trays, start-up time is approximately 8 minutes. |
Component |
Specification (WxDxH) |
CBLM | 19.01 x 35.10 x 6.86 inches (483 x 891.7 x 174.3 mm) |
Component |
Specification |
CBLM | 187.39 pounds (85 kg) |
Component |
Specification |
CBLM | 4 U |
Item |
Specification |
Capacity (GB) |
VSP F400: 128 VSP F600: 256 |
NAS module Cache Capacity |
DDR3 DIMM 8GB x 12 [Slot] Note:
|
Control method |
Read LRU, Write after |
Battery backup |
Provided |
Backup duration |
Unrestricted (saving to a nonvolatile memory) |
Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.
When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.
When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.
The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.
Item |
Specification |
Insulation withstand voltage |
AC 1,500 V (100 mA, 1 min) |
Insulation resistance |
DC 500 V, 10 M Ω or more |