Hitachi Virtual Storage Platform F400, F600 hardware overview

 

Hitachi Virtual Storage Platform F400, F600 are modular, rack-mountable, all-flash arrays that deliver high performance, high reliability, and flash-accelerated scalability.

The storage system contain dual controllers, each controller contains its own processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, fans and iSCSI and Fibre Channel I/O modules. Each controller also has an Ethernet connection for out-of-band management. If the data path through one controller fails, all data drives remain available to data hosts using a redundant data path through the other controller.

The storage system can be equipped with embedded network-attached storage (NAS) modules. The NAS modules provide file access through CIFS and NFS protocols and block access by using iSCSI protocols.

All storage system models allow defective drives to be replaced without the interruption of data availability to hosts. A hot spare drive can be configured to replace a failed drive automatically, securing the fault-tolerant integrity of the logical drives. Self-contained, hardware-based RAID logical drives provide maximum performance in compact external enclosures.

Essential hardware components are implemented with a redundant configuration so that the storage system can remain operational if a component fails. Adding and replacing components, along with firmware upgrades, can be conducted while the storage system is active.

Block configuration

 

A storage system configured for block-level storage provides the ability to access and provision raw storage volumes using protocols such as Fibre Channel and iSCSI.

A block configuration consists of the following:

  • Two controllers
  • One or more drive trays
  • One 1U service processor server (SVP)

Unified configuration

 

A unified configuration includes embedded NAS modules that support file system protocols such as CIFS and NFS and operate across a block-level setup using iSCSI or FC connections.

  • Two controllers
  • Two NAS modules for file operations and storage
  • One or more drive trays for block-level storage
  • One 1U block service processor server (SVP)

VSP F400 model

 

The VSP F400 is a highly reliable all-flash system that offers high storage capacity with full redundancy to better protect data and manage storage operations.

The storage system consists of a 4U enclosure that includes two controllers and two optional NAS modules to support file operations. Drives are supported using drive trays connected to the controllers.

Controller

Controller chassis

Controller model

Height

CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm)

Controller

Model number

Description

NAS

DW-F800-NAS

Optional component for file storage configuration. NAS modules only provide file support.

Drive tray

Drive tray model name

Supported drive type

Number of drives supported

Height

FMD tray DW-F800-DBF 5.25-inch FMD 12 2U (86.2 mm)
SFF drive tray
  • DW-F800-DBS (power supply, contains BNST)
  • DW-F800-DBSC
2.5-inch SFF 16 2U (86.2 mm)

High-speed cache memory

The storage system supports 128 GB of high-speed cache memory. The DIMMs are arranged as 64 GB or 128 GB per controller.

Flash module drives

The VSP F400 storage system supports up to 192 flash module drives. The total raw flash capacity is 2,702 TB.

Model number

Drive type

Drive capacity

DKC-F810I-1R6FN

FMD DC2

1.6 TiB
DKC-F810I-3R2FN

FMD DC2

3.2 TiB
DKC-F810I-6R4FN

FMD DC2

6.4 TiB
DKC-F810I-7R0FP

FMD HD

7 TB
DKC-F810I-14RFP

FMD HD

14 TB

Solid-state drives

The VSP F400 storage system supports up to 384 SSDs. The total raw flash capacity is 1,451 TB.

Model number

Drive type

Drive capacity

DKC-F810I-1R9MGM

SSD

1.9 TB
DKC-F810I-3R8MGM

SSD

3.8 TB

Interface ports

Interface ports for attachment to hosts are provided on the front-end modules. The system supports up to 16 front-end modules.

Model number

Description

Maximum number of ports supported
DW-F800-2HS10S 10-Gbps iSCSI (Optical) front-end module

28 (NAS modules not installed)

12 (NAS modules installed)

DW-F800-2HS10B 10-Gbps iSCSI (Copper) front-end module

28 (NAS modules not installed)

12 (NAS modules installed)

DW-F800-4HF8 8-Gbps Fibre Channel (4-port) front-end module

56 (NAS modules not installed)

24 (NAS modules installed)

DW-F800-2HF16 16-Gbps Fibre Channel (2-port) front-end module

28 (NAS modules not installed)

12 (NAS modules installed)

DW-F800-4HF32R 32/16-Gbps Fibre Channel (4-port) front-end module

56 (NAS modules not installed)

24 (NAS modules installed)

VSP F600 model

 

The VSP F600 is a highly reliable all-flash system that offers high storage capacity with full redundancy to better protect data and manage storage operations.

The storage system consists of a 4U enclosure that includes two controllers, two optional NAS modules to support file operations. The drives are supported using drive trays connected to the controllers.

Controller

Controller chassis

Controller model

Height

CBLM DW800-CBL DW-F800-CTLM 4U (174.3 mm)

Controller

Model number

Description

NAS

DW-F800-NAS

Optional component for file storage configuration. NAS modules only provide file support.

Drive tray

Drive tray model name

Supported drive type

Number of drives supported

Height

FMD tray DW-F800-DBF 5.25-inch FMD 12 2U (86.2 mm)
SFF drive tray
  • DW-F800-DBS (power supply, contains BNST)
  • DW-F800-DBSC
2.5-inch SFF 24 2U (86.2 mm)

High-speed cache memory

The storage system supports 256 GB of high-speed cache memory. The DIMMs are arranged as 64 GB or 128 GB per controller.

Flash module drives

The VSP F600 storage system supports up to 288 flash module drives. The total raw flash capacity is 4,053 TB.

Model number

Drive type

Drive capacity

DKC-F810I-1R6FN

FMD DC2

1.6 TiB
DKC-F810I-3R2FN

FMD DC2

3.2 TiB
DKC-F810I-6R4FN

FMD DC2

6.4 TiB
DKC-F810I-7R0FP

FMD HD

7 TB
DKC-F810I-14RFP

FMD HD

14 TB

Solid-state drives

The VSP F600 storage system supports up to 576 SSDs. The total raw flash capacity is 2,177 TB.

Model number

Drive type

Drive capacity

DKC-F810I-1R9MGM

SSD

1.9 TB
DKC-F810I-3R8MGM

SSD

3.8 TB

Interface ports

Interface ports for attachment to hosts are provided on the front-end modules. The system supports up to 16 front-end modules.

Model number

Description

Maximum number of ports supported
DW-F800-2HS10S 10-Gbps iSCSI (Optical) front-end module

28 (NAS modules not installed)

12 (NAS modules installed)

DW-F800-2HS10B 10-Gbps iSCSI (Copper) front-end module

28 (NAS modules not installed)

12 (NAS modules installed)

DW-F800-4HF8 8-Gbps Fibre Channel (4-port) front-end module

56 (NAS modules not installed)

24 (NAS modules installed)

DW-F800-2HF16 16-Gbps Fibre Channel (2-port) front-end module

28 (NAS modules not installed)

12 (NAS modules installed)

DW-F800-4HF32R 32/16-Gbps Fibre Channel (4-port) front-end module

56 (NAS modules not installed)

24 (NAS modules installed)

Features

 

The features described in the table are included with VSP F400 and VSP F600.

Feature

Value

Maximum cache memory supported VSP F400: 128 GB

VSP F600: 256 GB

Maximum number of spare drives

32

Maximum number of RAID groups

16

Maximum volume size

3 TB (4 TB when using the LDEVs of other Storage Systems)

Maximum number of volumes per host groups

2,048
Maximum number of host groups per port 255
Maximum number of volumes per port 2,048

Maximum number of volumes per RAID group

2,048

Maximum number of iSCSI hosts connected through a network switch

255

Maximum number of Fibre Channel devices connected through a Fibre Channel switch

255

Scalability

 

All storage systems offer pay-as-you-grow scalability by allowing you to hot-add drives as you need them.

Examples of supported VSP F400 configurations

 

The following table lists the maximum number of drive trays and drives supported in a system configuration. A diskless configuration does not include any drive trays.

Drive tray

Maximum number of drive trays supported

Maximum number of drives supported

SFF drive tray 16 384 SSDs
FMD tray 16 192 Hitachi Accelerated Flash (HAF) flash module drives
FMD2 tray 1 8 DC2 flash module drives + 1 spare

Examples of supported VSP F600 configurations

 

The following table lists the maximum number of drive trays and drives supported in a system configuration. A diskless configuration does not include any drive trays.

Drive tray

Maximum number of drive trays supported

Maximum number of drives supported

SFF drive tray 24 576 SSDs
FMD drive tray 24 288 HAF flash module drives
FMD2 drive tray 2 16 DC2 flash module drives + 1 spare

Maximum number of mounted drive trays

 

The following table lists the maximum number of mountable drive trays and mountable drives for each drive type.

VSP F400 controller

Drive trays

Maximum number of trays

Maximum number of drives

CBLM

FMD

16

192 FMDs (HAF)

4

48 FMDs

FMD

1

8 FMDs + 1 spare (DC2)

SFF

16

384 SSDs

VSP F600 controller

Drive trays

Maximum number of trays

Maximum number of drives

CBLM

FMD

24

288 FMDs (HAF)

4

48 FMDs

FMD

2

16 FMDs + 1 spare (DC2)

SFF

24

576 SSDs

 

  • Was this article helpful?