Virtual Storage Platform G200 controllers
The Virtual Storage Platform G200 model equipped with dual controllers for communicating with a data host.
Each controller includes the following internal components such as a processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator. If the data path through one controller fails, all drives remain available to data hosts using a redundant data path through the other controller. The controller is equipped with LED indicators for monitoring its operating conditions and notifying possible component replacement.
CBSS controller
The CBSS controller includes specific functional LEDs located on the front and rear of controller and power supplies to provide its operating status.
controller with front panel bezel
The following table describes the definitions of the CBSS controller front panel bezel LEDs.
Number |
Item |
Description |
1 |
POWER LED |
Green: Storage system is powered on. Amber: Storage system is receiving power. |
2 |
READY LED |
Green: Normal operation. |
3 | WARNING LED |
Off: Normal operation. Amber: Component requires maintenance. Blink: Failure requires maintenance. Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. |
4 |
ALARM LED |
Off: Normal operation. Red: Processor failure (system might be down). Go to the Customer Contact Us page at https://support.hitachivantara.com/en_us/contact-us.html. |
5 |
POWER ON/OFF (main switch) |
Powers the storage system. |
6 |
Lock |
Locks and unlocks the front panel bezel by using the supplied key. |
front panel LEDs (without bezel)
The following table describes the definitions of the CBSS controller front panel LEDs.
Number |
Item |
Description |
1 |
ACT LED |
Green: Normal operation. Blink green: Drive is being accessed. |
2 |
ALM LED |
Red: Drive stopped due to a failure and can be replaced. |
3 |
POWER, READY, WARNING, and ALARM LEDs |
Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. |
4 |
POWER ON/OFF (main switch) |
Powers the storage system. |
5 |
Small form factor drives |
The twenty-four 2.5-inch small form factor drives are positioned vertically. The slots are organized from 0 to 23. |
rear panel LEDs
The following table describes the definitions of the CBSS controller rear panel LEDs.
Number |
Item |
Description |
1 |
Controllers |
Controller 1 (left) and Controller 2 (right). |
2 |
Front end module | N/A |
3 |
CTL ALM LED |
Red: Controller can be removed. Blink red: Failure with the power supply unit of the controller. Amber: LAN reset switch was pressed. |
4 |
BACKUP STTS LED |
Green: Power restoration in progress following power outage. Fast blink green: Restoring. Slow blink green: Restoring, or sequential shutdown in progress. |
5 |
CTL WARN LED |
Amber blink one time: Failure with fan 0. Amber blink two times: Failure with fan 1. |
6 |
Cache flash memory | N/A |
7 |
LAN-RST switch |
Use only when instructed by customer support. |
8 |
LAN port |
Maintenance LAN port (left) and user LAN port (right). |
9 |
Uninterruptible power supply (UPS) port | N/A |
10 |
ALARM LED (for cache flash memory) |
Red: Cache flash memory can be removed. |
11 |
Backup module | N/A |
12 | STATUS |
Green: Charging of the battery in the backup module is complete. Blink green: Battery in the backup module is charging or discharging. Red: Backup module can be removed. Blink red: Backup module can be removed. Blink red one time: Battery failure Off: battery is not installed, failure occurred, or firmware is being upgraded. |
13 |
SAS port | N/A |
14 |
Port LED |
Blue: Port link is established. |
15 |
Power supply unit | N/A |
CBSS/CBSL AC power supply unit LEDs and connectors
The following table describes the definitions of the CBSS and CBSL AC power supply unit LEDs and connectors.

Number |
Item |
Description |
1 |
Receptacle |
Connects to the power cable provided with the storage system. |
2 |
AC IN LED |
Blue: AC input is normal. |
3 |
ALM/RDY LED |
Red: Power supply unit can be replaced. Green: Normal operation. |
CBSSD/CBSLD DC power supply unit LEDs and connectors
The following table describes the definitions of the CBSSD and CBSLD DC power supply unit LEDs and connectors.

Number |
Item |
Description |
1 |
ALM/RDY LED |
Red: Power supply unit can be replaced. Green: Normal operation. |
2 |
DC IN LED |
Blue: DC input is normal. |
CBSL controller
The CBSL controller includes specific functional LEDs located on the front and rear of controller and power supplies to provide its operating status.
CBSL with front panel bezel
The following table describes the definitions of the CBSL controller front panel bezel LEDs.

Number |
Item |
Description |
1 |
POWER LED |
Green: Storage system is powered on. Amber: Storage system is receiving power. |
2 |
READY LED |
Green: Normal operation. |
3 | WARNING LED |
Off: Normal operation. Amber: Component requires maintenance. Blink: Failure requires maintenance. Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. LED might turn off during user maintenance. |
4 |
ALARM LED |
Off: Normal operation. Red: Processor failure (system might be down). Go to the Customer Contact Us page at https://support.hitachivantara.com/en_us/contact-us.html. |
5 |
POWER ON/OFF (main switch) |
Powers the storage system. |
6 |
Lock |
Locks and unlocks the front panel bezel by using the supplied key. |
CBSL front panel without bezel
The following table describes the definitions of the CBSL controller front panel LEDs.
Number |
Item |
Description |
1 |
ACT LED |
Green: Normal operation. Blink green: Drive is being accessed. |
2 |
ALM LED | Red: Drive stopped due to a failure and can be replaced. |
3 |
POWER, READY, WARNING, and ALARM LEDs |
Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100. |
4 |
POWER ON/OFF (main switch) |
Powers the storage system. |
5 |
Large form factor drives |
The twelve 3.5-inch large form factor drives are positioned horizontally. The slots are organized in the following order: 8 9 10 11 4 5 6 7 0 1 2 3 |
CBSL rear panel
The following table describes the definitions of the CBSL controller rear panel LEDs.
Number |
Item |
Description |
1 |
Controllers |
Controller 1 (left) and Controller 2 (right). |
2 |
Front end module | N/A |
3 |
CTL ALM LED |
Red: Controller can be removed. Blink red: Failure with the power supply unit of the controller. Amber: LAN reset switch was pressed. |
4 |
BACKUP STTS LED |
Green: Power restoration in progress following power outage. Fast blink green: Restoring. Slow blink green: Restoring, or sequential shutdown in progress. |
5 |
CTL WARN LED |
Amber blink one time: Failure with fan 0. Amber blink two times: Failure with fan 1. |
6 |
Cache flash memory | N/A |
7 |
LAN-RST switch |
Use only when instructed by customer support. |
8 |
LAN port |
Maintenance LAN port (left) and user LAN port (right). |
9 |
Uninterruptible power supply (UPS) port | N/A |
10 |
ALARM LED (for cache flash memory) |
Red: Cache flash memory can be removed. |
11 |
Backup module | N/A |
12 | STATUS |
Green: Charging of the battery in the backup module is complete. Blink green: Battery in the backup module is charging or discharging. Red: Backup module can be removed. Blink red: Backup module can be removed. Blink red one time: Battery failure Off: Battery is not installed, failure occurred, or firmware is being upgraded. |
13 |
SAS port | N/A |
14 |
Port LED |
Blue: Port link is established. |
15 |
Power supply unit | N/A |
CBSS/CBSL AC power supply unit LEDs and connectors
The following table describes the definitions of the CBSS and CBSL AC power supply unit LEDs and connectors.

Number |
Item |
Description |
1 |
Receptacle |
Connects to the power cable provided with the storage system. |
2 |
AC IN LED |
Blue: AC input is normal. |
3 |
ALM/RDY LED |
Red: Power supply unit can be replaced. Green: Normal operation. |
CBSSD/CBSLD DC power supply unit LEDs and connectors
The following table describes the definitions of the CBSSD and CBSLD DC power supply unit LEDs and connectors.

Number |
Item |
Description |
1 |
ALM/RDY LED |
Red: Power supply unit can be replaced. Green: Normal operation. |
2 |
DC IN LED |
Blue: DC input is normal. |
Host, Network, and Drive Tray Ports and LEDs
The controllers are equipped with specific interfaces for connecting, powering, configuring, and managing the storage system. The component LEDs display the operating status of the storage system.
Front end module descriptions
The front end module LEDs display the operating status of the module.
10-Gbps iSCSI board LEDs and connectors (optical)

Number |
Item |
Description |
1 |
STATUS LED |
Green: Front end module is in the power-on state. Red: Front end module can be removed safely. |
2 |
PORT LED |
Red: Small form factor pluggable can be removed. Blue: Normal link status. Blink blue: Front end module is in communication status. |
3 |
iSCSI connectors |
Connect to Ethernet LAN cables. |
10-Gbps iSCSI board LEDs and connectors (copper)

Number |
Item |
Description |
1 |
STATUS LED |
Green: Front end module is in the power-on state. Red: Front end module can be removed safely. |
2 |
PORT (Link/Speed) LED |
Yellow: 1-Gbps link. Green: 10-Gbps link. Off: No link connection. |
3 |
PORT LED |
Green: Link connection is established. Blinking: Communication is in progress. Off: No link connection or not ready to communicate. |
4 |
iSCSI connectors |
Connect to Ethernet LAN cables. |
8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel (4-port) board LEDs and connectors
Number |
Item |
Description |
1 |
Fibre Channel connectors |
Connect to Fibre Channel cables. |
2 |
STATUS LED |
Green: Front end module is in power-on state. Red: Front end module can be removed safely. |
3 |
PORT LED |
Red: Small form factor pluggable can be removed. Blue: Normal link status at 8-Gbps. Green: Normal link status at 2-Gbps or 4-Gbps. |
Number |
Item |
Description |
1 |
Fibre Channel connectors |
Connect to Fibre Channel cables. |
2 |
STATUS LED |
Green: Front end module is in power-on state. Red: Front end module can be removed safely. |
3 |
PORT LED |
Red: Small form factor pluggable can be removed. Blue: Normal link status at 16-Gbps (16-Gbps). Blue: Normal link status at 32-Gbps (32-Gbps). Green: Normal link status at 4-Gbps or 8-Gbps (16-Gbps). Green: Normal link status at 8-Gbps or 16-Gbps (32-Gbps). |
CHB number |
8-Gbps, 16-Gbps, or 32-Gbps Fibre Channel Ports (left to right) | |||
Port 1 |
Port 2 |
Port 3 |
Port 4 | |
CHB-1A |
1A |
3A |
5A |
7A |
CHB-1B |
1B |
3B |
5B |
7B |
CHB-1C |
1C |
3C |
5C |
7C |
CHB-1D |
1D |
3D |
5D |
7D |
CHB-1E |
1E |
3E |
5E |
7E |
CHB-1F |
1F |
3F |
5F |
7F |
CHB-1G |
1G |
3G |
5G |
7G |
CHB-1H |
1H |
3H |
5H |
7H |
CHB-2A |
2A |
4A |
6A |
8A |
CHB-2B |
2B |
4B |
6B |
8B |
CHB-2C |
2C |
4C |
6C |
8C |
CHB-2D |
2D |
4D |
6D |
8D |
CHB-2E |
2E |
4E |
6E |
8E |
CHB-2F |
2F |
4F |
6F |
8F |
CHB-2G |
2G |
4G |
6G |
8G |
CHB-2H |
2H |
4H |
6H |
8H |
16-Gbps Fibre Channel (2-port) board LEDs and connectors

Number |
Item |
Description |
1 | STATUS LED |
Green: Front end module is in the power-on state. Red: Front end module can be removed safely. |
2 |
PORT LED |
Red: Small form factor pluggable can be removed. Blue: Normal link status at 16-Gbps. Green: Normal link status at 4-Gbps or 8-Gbps. |
3 |
Fibre Channel connectors |
Connect to Fibre Channel cables. |
CHB number |
16-Gbps Fibre Channel Ports (left to right) | |
Port 1 |
Port 2 | |
CHB-1A |
1A |
3A |
CHB-1B |
1B |
3B |
CHB-1C |
1C |
3C |
CHB-1D |
1D |
3D |
CHB-1E |
1E |
3E |
CHB-1F |
1F |
3F |
CHB-1G |
1G |
3G |
CHB-1H |
1H |
3H |
CHB-2A |
2A |
4A |
CHB-2B |
2B |
4B |
CHB-2C |
2C |
4C |
CHB-2D |
2D |
4D |
CHB-2E |
2E |
4E |
CHB-2F |
2F |
4F |
CHB-2G |
2G |
4G |
CHB-2H |
2H |
4H |
LAN blade LEDs and connectors

Number |
Item |
Description |
1 |
ACT LED | Green: Data is being transferred. |
2 | LINK LED | Green: Link status is normal. |
3 |
LAN 2 |
LAN port used by the user. |
4 |
LAN 1 |
Maintenance LAN port used by service personnel. |
5 |
LAN ALARM LED |
Red: LAN blade can be removed. |
6 |
Uninterruptible power supply (UPS) port |
N/A |
Back end module LEDs and connectors
The back end module LEDs display the operating status of the module.

Number |
Item |
Description |
1 |
PATH 1 connector |
Connects to a drive tray. |
2 |
PORT LED |