VSP G400, G600 storage system components
The VSP G400, G600 includes essential building blocks such as controllers, drive trays, and other optional front and back end components.
Model lists
VSP G400 and VSP G600 controller model lists
Model number |
Part name |
Quantity |
DW800-CBL | 4U chassis | 1 |
Power supply unit | 2 | |
Power cable (0.9 m) | 2 | |
Power cable (2.5 m) | 2 | |
LAN blade (local-area network, uninterruptible power supply) | 2 | |
Backup module | 8 | |
Front bezel (4U) | 1 | |
DW-F800-CTLM | Controller | 2 |
DW-F800-BAT | Battery | 6 |
Model number |
Part name |
Quantity |
DW-F800-CTLM | Controller Board | 2 |
DKC-F810I-CM8G | Cache memory (8 GB) | 8-16 |
DKC-F810I-CM16G | Cache memory (16 GB) | 8-16 |
DW-F800-BM20 | Cache flash memory | 2-4 |
DW-F800-2HS10S | Front end module (10 Gbps SFP iSCSI optical) | 2-16 |
DW-F800-2HS10B | Front end module (10 Gbps copper iSCSI copper) | 2-16 |
DW-F800-4HF8 | Front end module (8 Gbps FC) | 2-16 |
DW-F800-2HF16 | Front end module (16 Gbps 2-port FC) | 2-16 |
DW-F800-4HF32R | Front end module (32 / 16 Gbps 4-port FC) | 2-16 |
DW-F800-NAS | NAS Module | 0-2 |
DW-F800-BS12G | SAS Back end module | 0-2 |
DW-F800-BS12GE | SAS Back end module (encryption) | 0-2 |
DKC-F810I-1PS8 | SFP for 8 Gbps shortwave | 0-64 |
DKC-F810I-1PL8 | SFP for 8 Gbps longwave | 0-64 |
DKC-F810I-1PS16 | SFP for 16 Gbps shortwave | 0-64 |
DKC-F810I-1PS32 | SFP for 32 Gbps shortwave | 0-64 |
DW-F800-BAT | Battery | 0-14 |
N/A | SAS cable label | 2 |
Drive tray model lists
Model number |
Part name |
Quantity |
DW-F800-DBS and DW-F800-DBSC | 2U chassis | 1 |
ENC | 2 | |
AC power supply unit | 2 | |
Power cable (0.9 m) | 2 | |
Power cable (2.5 m) | 2 | |
Front bezel (2U) | 1 |
Model number |
Part name |
Quantity |
DKC-F810I-200MEM1 | 200 GB, MLC, 12-Gbps, SFF, flash drive | 0-24 |
DKC-F810I-300KCMC1 | 300 GB, 15kmin, 6-Gbps, SAS, SFF, drive | 0-24 |
DKC-F810I-400MEM1 | 400GB, MLC, 12-Gbps, SFF, flash drive | 0-24 |
DKC-F810I-600JCM1 | 600 GB, 10kmin, 6-Gbps, SAS, SFF, drive (contains BNST) | 0-24 |
DKC-F810I-600JCMC1 | 600 GB, 10kmin, 6-Gbps, SAS, SFF, drive | 0-24 |
DKC-F810I-600KGM1 | 600 GB, 15kmin, 6-Gbps, SAS, SFF, drive | 0-24 |
DKC-F810I-1R2JCMC1 | 1.2-TB, 10kmin, 6-Gbps, SAS, SFF, drive | 0-24 |
DKC-F810I-1R8JGM1 | 1.8-TB, 10kmin, 6-Gbps, SAS, SFF, drive | 0-24 |
DKC-F810I-1R9MEM1 | 1.92 TB, 2.5-inch, MLC, 12-Gbps, SAS, drive | 0-24 |
1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. |
Model number |
Part name |
Quantity |
DW-F800-DBL and DW-F800-DBLC | 2U chassis | 1 |
ENC | 2 | |
AC power supply unit | 2 | |
Power cable (0.9 m) | 2 | |
Power cable (2.5 m) | 2 | |
Front bezel (2U) | 1 |
Model number |
Part name |
Quantity |
DKC-F810I-400M6M1 | 400 GB, LFF, Flash drive | 0-12 |
DKC-F810I-1R2J5MC1 | 1.2 TB, SAS, LFF, drive | 0-12 |
DKC-F810I-1R8J6M1 | 1.8 TB, 10k, 6-Gbps, SAS, LFF, drive | 0-12 |
DKC-F810I-4R0H3M1 | 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive (contains BNST) | 0-12 |
DKC-F810I-4R0H3MC1 | 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive | 0-12 |
DKC-F810I-6R0H9M1 | 6 TB, 7.2K, 12-Gbps, SAS, LFF, drive | 0-12 |
DKC-F810I-10RH9M | 10 TB, 7.2K, 12-Gbps, SAS, LFF, drive | 0-12 |
1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. |
Model number |
Part name |
Quantity |
DW-F800-DBF | 2U chassis | 1 |
ENC | 2 | |
Power supply unit | 2 | |
Power cable (0.9 m) | 2 | |
Power cable (2.5 m) | 2 | |
Front bezel (2U) | 1 |
Model number |
Part name |
Quantity |
DKC-F710I-1R6FM1 | 1.75 TB, MLC, 6-Gbps, Flash Module Drive | 0-12 |
DKC-F710I-3R2FM1 | 3.5, TB, MLC, 6-Gbps, Flash Module Drive | 0-12 |
DKC-F810I-1R6FN1 | 1.75 TB, Flash Module Drive | 0-12 |
DKC-F810I-3R2FN1 | 3.5 TB, Flash Module Drive | 0-12 |
DKC-F810I-6R4FN1 | 7 TB, Flash Module Drive | 0-12 |
DKC-F810I-7R0FP1 | 7 TB, MLC, 12-Gbps, Flash Module Drive | 0-12 |
DKC-F810I-14RFP1 | 14 TB, MLC, 12-Gbps, Flash Module Drive | 0-12 |
1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. |
Model number |
Part name |
Quantity |
DW-F800-DB60 and DW-F800-DB60C | 4U box | 1 |
ENC | 2 | |
Power supply unit | 2 | |
Power cable (0.9 m) | 2 | |
Power cable (2.5 m) | 2 | |
Front bezel (dense intermix drive tray) | 1 | |
DW-F800-SCQ3 | SAS cable (3 m), including 2 omega clips
(DW-F800-SCQ3) | 2 |
Model number |
Part name |
Quantity |
DKC-F810I-400M8M1 | 400 GB, MLC, 12-Gbps, flash drive | 0-60 |
DKC-F810I-1R2J7M1 | 1.2 TB, 10k, 6-Gbps, SAS, SFF, drive (contains BNST) | 0-60 |
DKC-F810I-1R2J7MC1 | 1.2 TB, 10k, 6-Gbps, SAS, SFF, drive | 0-60 |
DKC-F810I-1R8J8M1 | 1.8 TB, 10k, 6-Gbps, SAS, LFF drive | 0-60 |
DKC-F810I-1R9MEM1 | 1.92 TB, 2.5-inch, MLC, 12-Gbps, SAS, drive | 0-60 |
DKC-F810I-4R0H4M1 | 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive (contains BNST) | 0-60 |
DKC-F810I-4R0H4MC1 | 4 TB, 7.2K, 6-Gbps, SAS, LFF, drive | 0-60 |
DKC-F810I-6R0HLM1 | 6 TB, 7.2K, 12-Gbps, SAS, LFF, drive | 0-60 |
DKC-F810I-10RHLM1 | 10 TB, 7.2K, 12-Gbps, SAS, LFF, drive | 0-60 |
1 The drive capacity values are calculated as 1 G byte =1,000,000,000 bytes. This definition is different from that calculated as 1 k byte =1,024 bytes, which are actually displayed on PCs that you are using. The parity group capacity values displayed in the storage management software are calculated as 1 k byte =1,024 bytes. |
Cable model list
Numbers in parentheses show the quantities of the components.
Model number |
Specification |
DW-F800-J1K | 2.5 m, 2-pole power cable with grounding terminal (AC 125 V, 13 A or 15 A) |
DW-F800-J2H | 2.5 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A) |
DW-F800-J2H5 | 5.0 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A) |
DW-F800-J2H10 | 10.0 m, 2-pole power cable with grounding terminal (AC 250 V, 13 A or 15 A) |
A-F6516-P620 | Power cable for PDU (1) |
A-F6516-P630 | Power cable for PDU (1) |
Model number |
Specification |
DW-F800-SCQ1 | 1 m SAS cable, including omega clips (2) |
DW-F800-SCQ1F | 1.5 m SAS cable, including omega clips (2) |
DW-F800-SCQ3 | 3 m SAS cable, including omega clips (2) |
DW-F800-SCQ5 | 5 m SAS cable, including omega clips (2) |
DW-F800-SCQ10A | 10 m SAS optical cable |
DW-F800-SCQ30A | 30 m SAS optical cable |
DW-F800-SCQ1HA | 100 m SAS optical cable |
Model number |
Specification |
A-6515-GM5L | 5 m LC-LC optical cable for optical |
A-6515-GM10L | 10 m LC-LC optical cable for optical |
A-6515-GM20L | 20 m LC-LC optical cable for optical |
A-6515-GM30L | 30 m LC-LC optical cable for optical |
A-6515-GM40L | 40 m LC-LC optical cable for optical |
A-6515-GM50L | 50 m LC-LC optical cable for optical |
A-6515-GM1JL | 100 m LC-LC optical cable for optical |
A-6515-GS10L | 10 m LC-LC optical cable for optical |
A-6515-GS20L | 20 m LC-LC optical cable for optical |
A-6515-GS30L | 30 m LC-LC optical cable for optical |
A-6515-GS50L | 50 m LC-LC optical cable for optical |
A-6515-GS1JL | 100 m LC-LC optical cable for optical |
A-6515-HM5L | 5 m LC-LC optical cable for optical |
A-6515-HM10L | 10 m LC-LC optical cable for optical |
A-6515-HM20L | 20 m LC-LC optical cable for optical |
A-6515-HM30L | 30 m LC-LC optical cable for optical |
A-6515-HM50L | 50 m LC-LC optical cable for optical |
A-6515-HM100L | 100 m LC-LC optical cable for optical |
A-6515-HM200L | 200 m LC-LC optical cable for optical |
A-6515-HM300L | 300 m LC-LC optical cable for optical |
A-6515-JM5L | 5 m LC-LC optical cable for optical |
A-6515-JM10L | 10 m LC-LC optical cable for optical |
A-6515-JM20L | 20 m LC-LC optical cable for optical |
A-6515-JM30L | 30 m LC-LC optical cable for optical |
A-6515-JM50L | 50 m LC-LC optical cable for optical |
A-6515-JM100L | 100 m LC-LC optical cable for optical |
A-6515-JM200L | 200 m LC-LC optical cable for optical |
A-6515-JM300L | 300 m LC-LC optical cable for optical |
Battery specifications
The following table shows the lifetime expectancy of the batteries installed in the storage system.
Storage system intake temperature | CBLM |
Up to 75.2º F (24º C) | 5 years |
Up to 86º F (30º C) | 5 years |
Up to 93.2º (34º C) | 4 years |
Up to 104º (40º C) | 3 years |
RAID specifications
Item |
SFF, LFF, dense intermix drive trays (range for setup) | ||
RAID level |
VSP G400, G600, G800 models and VSP F400, F600, F800 models: SAS, SAS 7.2 krpm, flash drives mounted: 0, 1, 5, 6, 1+0 (DBW supports SAS 7.2k drives) | ||
RAID configuration (unit of addition) | RAID 1 | 2D+2D, 4D+4D | |
RAID 5 | 3D+1P, 4D+1P, 6D+1P, 7D+1P | ||
RAID 6 | 6D+2P, 12D+2P, 14D+2P |