VSP G200 storage system mechanical specifications
The storage system mechanical specifications are described for VSP G200 .
VSP G200 mechanical specifications (AC power supply model)
Controller
1 CBSS
1 CBSL
Drive trays
1 SFF drive tray (DBS)
1 LFF drive tray (DBL)
1 FMD drive tray
1 dense intermix drive tray
Item |
Component |
Specification |
Drive size (WxDxH) | CBSS, SFF drive tray |
2.5-type: 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm) |
CBSL, LFF drive tray |
3.5-type: 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm) | |
FMD drive tray |
Flash module drive: 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm) | |
Data capacity (GB) | CBSS, SFF drive tray |
2.5-type: 196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29, 1890.46 |
CBSL, LFF drive tray, dense intermix drive tray |
3.5-type: 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36 | |
FMD drive tray |
Flash module drive: 1759.21, 3518.43 , 7036.87, 14073.74 GB | |
Rotational speed (min-1) | CBSS, SFF drive tray |
Flash drive, 2.5-type: 196.92 GB, 393.85 GB 2.5-type: 288.20 GB, 15,000 RPM 2.5-type: 576.39 GB, 10,000 or 15,000 RPM 2.5-type: 1152.79 GB, 10,000 RPM 2.5-type: 1729.29 GB, 10,000 RPM |
CBSL, LFF drive tray |
Flash drive, 3.5-type: 393.85 GB 3.5-type: 1152.79 GB, 10,000 RPM 3.5-type: 1729.29 GB, 10,000 RPM 3.5-type: 3916.14 GB, 7,200 RPM 3.5-type: 5874.22 GB, 7,200 RPM 3.5-type: 9790.36 GB, 7,200 RPM | |
FMD drive tray |
Flash module drive: 1759.21 GB, 3518.43 GB, 7036.87 GB, 14073.74 GB | |
Maximum number of drives that can be mounted | CBSS |
24 drives |
CBSL |
12 drives | |
SFF drive tray |
24 drives | |
LFF drive tray |
12 drives | |
FMD drive tray |
12 drives | |
Dense intermix drive tray |
60 drives | |
Maximum number of spare drives |
16 |
Item |
Component |
Specification |
Interface type |
Fibre Channel optical |
8-Gbps, 16-Gbps, 32-Gbps |
iSCSI optical |
10-Gbps | |
Copper iSCSI |
10-Gbps | |
Data transfer speed (maximum speed for transfer to host) |
Fibre Channel optical |
800-Mbps (Fibre Channel) |
Fibre Channel optical |
1600-Mbps (Fibre Channel) | |
Fibre Channel optical |
3200-Mbps (Fibre Channel) | |
iSCSI optical |
10-Gbps (iSCSI optical) | |
Copper iSCSI | 10-Gbps (copper iSCSI) | |
Number of ports |
8-Gbps Fibre Channel optical |
16 |
16-Gbps Fibre Channel optical (2-port) |
8 | |
16-Gbps Fibre Channel optical (4-port) |
16 | |
32-Gbps Fibre Channel optical |
16 | |
10-Gbps optical iSCSI |
8 | |
10-Gbps copper iSCSI |
8 | |
Transferred block size |
512 bytes | |
Maximum number of hosts using a Fibre Channel switch |
255 | |
Maximum number of hosts using a network switch |
255 |
Storage system intake temperature | CBSS | CBSL |
Up to 75.2º F (24º C) | 5 years | 5 years |
Up to 86º F (30º C) | 5 years | 4 years |
Up to 93.2º (34º C) | 4 years | 3 years |
Up to 104º (40º C) | 3 years | 2 years |
D: Data drive, P: Parity drive.
Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.
Item |
Drive tray |
RAID Level |
SAS, SAS 7.2k, flash drives mounted |
RAID 1 |
2D+2D, 4D+4D |
RAID 5 |
3D+1P, 4D+1P, 6D+1P, 7D+1P |
RAID 6 |
6D+2P, 12D+2P, 14D+2P |
Item |
Specification |
Maximum number of parity groups |
88 |
Maximum volume size |
3 TB (or 4 TB when using the LDEVs of other storage systems) |
Maximum volumes/host groups and iSCSI targets |
2,048 |
Maximum volumes/parity groups |
2,048 |
Item |
Component |
Specifications |
Shared memory |
Flash memory |
32 MB |
L3 cache memory |
4 MB | |
SDRAM |
1 GB | |
Data assurance method |
Data bus |
Parity |
Cache memory |
ECC (1 bit for correction, 2 bits for detection) | |
Drive |
Data assurance code |
Item |
Component |
Specifications |
Start-up time (min)1 | Controller |
Standard: 5 to 8 |
Drive trays |
Standard: 5 to 8 | |
Chassis size | Controller |
WxDxH: 19 x 32 x 3.5 inches (483 x 813 x 88 mm) |
SFF drive tray |
WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) | |
LFF drive tray |
WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) | |
FMD drive tray |
WxDxH: 19 x 30 x 3.4 inches (483 x 762 x 87 mm) | |
Dense intermix drive tray |
WxDxH: 19 x 40.5 x 7 inches (482 x 1029 x 176 mm) | |
Mass (approximate)2 | CBSS |
97 lbs (44 kg) |
CBSL |
101.4 lbs (46 kg) | |
SFF drive tray |
51 lbs (23 kg) | |
LFF drive tray |
59.5 lbs (27 kg) | |
FMD drive tray |
84 lbs (38 kg) | |
Dense intermix drive tray |
198 lbs (90 kg) | |
Required height | CBSS, CBSL | 2 |
SFF drive tray | 2 | |
LFF drive tray | 2 | |
FMD drive tray | 2 | |
Dense intermix drive tray | 4 | |
Notes
|
Item |
Specifications |
Capacity (GB) |
64 GB |
Control method |
Read LRU, Write after |
Battery backup |
Provided |
Backup duration |
Unrestricted (saving to a nonvolatile memory) |
Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.
When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.
When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.
The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.
Item |
Specifications |
Insulation withstand voltage |
AC 1,500 V (100 mA, 1 min) |
Insulation resistance |
DC 500 V, 10 M Ω or more |
VSP G200 mechanical specifications (DC power supply model)
Controller
1 CBSSD
1 CBSLD
Drive trays
1 SFF drive tray (DBSD)
1 LFF drive tray (DBLD)
Item |
Component |
Specification |
Drive size (WxDxH) | CBSSD, SFF drive tray |
2.5-type: 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm) |
CBSLD, LFF drive tray |
3.5-type: 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm) | |
Data capacity (GB) | CBSSD, SFF drive tray |
2.5-type: 196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29, 1890.46 |
CBSLD, LFF drive tray |
3.5-type: 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36 | |
Rotational speed (min-1) | CBSSD, SFF drive tray |
Flash drive, 2.5-type: 196.92 GB, 393.85 GB 2.5-type: 288.20 GB, 15,000 RPM 2.5-type: 576.39 GB, 10,000 or 15,000 RPM 2.5-type: 1152.79 GB, 10,000 RPM 2.5-type: 1729.29 GB, 10,000 RPM |
CBSLD, LFF drive tray |
Flash drive, 3.5-type: 393.85 GB 3.5-type: 1152.79 GB, 10,000 RPM 3.5-type: 1729.29 GB, 10,000 RPM 3.5-type: 3916.14 GB, 7,200 RPM 3.5-type: 5874.22 GB, 7,200 RPM 3.5-type: 9790.36 GB, 7,200 RPM | |
Maximum number of drives that can be mounted | CBSSD, SFF drive tray |
24 drives |
CBSLD, LFF drive tray |
12 drives | |
Maximum number of spare drives |
16 |
Storage system intake temperature | CBSS | CBSL |
Up to 75.2º F (24º C) | 5 years | 5 years |
Up to 86º F (30º C) | 5 years | 4 years |
Up to 93.2º (34º C) | 4 years | 3 years |
Up to 104º (40º C) | 3 years | 2 years |
Item |
Component |
Specification |
Interface type |
Fibre Channel optical |
8-Gbps, 16-Gbps, 32-Gbps |
iSCSI optical |
10-Gbps | |
Copper iSCSI |
10-Gbps | |
Data transfer speed (maximum speed for transfer to host) |
Fibre Channel optical |
800-Mbps (Fibre Channel) |
Fibre Channel optical |
1600-Mbps (Fibre Channel) | |
Fibre Channel optical |
3200-Mbps (Fibre Channel) | |
iSCSI optical |
10-Gbps (iSCSI optical) | |
Copper iSCSI | 10 Gbps (copper iSCSI) | |
Number of ports |
8-Gbps Fibre Channel optical |
16 |
16-Gbps Fibre Channel optical (2-port) |
8 | |
16-Gbps Fibre Channel optical (4-port) |
16 | |
32-Gbps Fibre Channel optical |
16 | |
10-Gbps optical iSCSI |
8 | |
10 Gbps copper iSCSI |
8 | |
Transferred block size |
512 bytes | |
Maximum number of hosts using a Fibre Channel switch |
255 | |
Maximum number of hosts using a network switch |
255 |
D: Data drive, P: Parity drive.
Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.
Item |
Drive tray |
RAID Level |
SAS, SAS 7.2k, flash drives mounted |
RAID 1 |
2D+2D, 4D+4D |
RAID 5 |
3D+1P, 4D+1P, 6D+1P, 7D+1P |
RAID 6 |
6D+2P, 12D+2P, 14D+2P |
Item |
Specification |
Maximum number of parity groups |
88 |
Maximum volume size |
3 TB (or 4 TB when using the LDEVs of other storage systems) |
Maximum volumes/host groups and iSCSI targets |
2,048 |
Maximum volumes/parity groups |
2,048 |
Item |
Component |
Specifications |
Shared memory |
Flash memory |
32 MB |
L3 cache memory |
4 MB | |
SDRAM |
1 GB | |
Data assurance method |
Data bus |
Parity |
Cache memory |
ECC (1 bit for correction, 2 bits for detection) | |
Drive |
Data assurance code |
Item |
Component |
Specifications |
Start-up time (min)1 | Controller |
Standard: 5 to 8 |
Drive trays |
Standard: 5 to 8 | |
Chassis size | Controller |
WxDxH: 19 x 32 x 3.5 inches (483 x 813 x 88 mm) |
SFF drive tray |
WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) | |
LFF drive tray |
WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm) | |
Mass (approximate)2 | CBSSD |
97 lbs (44 kg) |
CBSLD |
101.4 lbs (46 kg) | |
SFF drive tray |
51 lbs (23 kg) | |
LFF drive tray |
59.5 lbs (27 kg) | |
Required height | CBSSD, CBSLD | 2 |
SFF drive tray | 2 | |
LFF drive tray | 2 | |
Notes
|
Item |
Specifications |
Capacity (GB) |
64 GB |
Control method |
Read LRU, Write after |
Battery backup |
Provided |
Backup duration |
Unrestricted (saving to a nonvolatile memory) |
Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.
When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.
When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.
The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.
Item |
Specifications |
Insulation withstand voltage |
AC 1,500 V (100 mA, 1 min) |
Insulation resistance |
DC 500 V, 10 M Ω or more |