Storage system components

The Hitachi Virtual Storage Platform G200, G400, G600, G800 storage systems and Hitachi Virtual Storage Platform F400, F600, F800 all-flash arrays are modular, rack-mountable systems that incorporate state-of-the-art virtualization, data-management, and fault-tolerant technologies.

All models are compatible with most industry-standard 4-post EIA 19-inch racks with square mounting holes. The storage system can be factory-configured and shipped in a Hitachi 600 x 1200 mm V2 Universal Rack, or shipped without a rack for customer installation into an existing rack.

The Hitachi rack comes with either two or four Power Distribution Units (PDUs), depending on the PDU model selected. The PDUs are installed vertically in the rack.

  • If two PDUs are selected, one will be installed on the left side of the rack and the other will be installed on the right side.
  • If four PDUs are selected, the PDUs will be half-length and mounted vertically, one above the other, with two on the left side of the rack and two on the right side.

All storage systems are comprised of controllers, drive trays, and a service processor (SVP).

Controllers Controllers are components in the storage system that cache and manage data, and provide hosts with a coherent, virtualized view of the system. All storage systems have two controllers.

The controllers for the Hitachi Virtual Storage Platform G200 include either 24 2.5-inch small form-factor (SFF) disk drives or 12 3.5-inch large form-factor (LFF) disk drives.

Drive trays

Drive trays are intelligent and compact storage units, with each capable of holding a large numbers of disk drives in a small rack space (EIA-standard rack units). VSP G200, G400, G600, G800 storage systems support the following drive trays and drives:

  • DW-F800-DBS: 2U drive tray that holds 24 2.5-inch SFF disk drives. Drives are arranged vertically in a single row.
  • DW-F800-DBL: 2U drive tray that holds 12 3.5-inch LFF disk drives. Drives are arranged horizontally, with four columns of three disk drives.
  • DW-F800-DBF: 2U drive tray that holds 12 Hitachi Accelerated Flash (HAF) or DC2 flash module drives. Drives are arranged horizontally, with three columns of three disk drives.
  • DW-F800-DB60: 4U dense drive tray that holds 60 LFF disk drives. Drives are arranged horizontally, with five rows of 12 disk drives.

VSP F400, F600, F800 all-flash array models support various fixed storage capacity configurations of DC2 flash module drives within the DW-F800-DBF drive tray. To deliver consistent low latency host response times and highest IOP performance across all host connection ports, no HDDs are included or permitted to be configured as part of the all-flash array configurations.

NAS modules

Some storage systems support NAS modules for sharing file-based information over an IP network using system protocols such as Common Internet File System (CIFS), Network File System (NFS), and Server Message Block (SMB). NAS modules are installed in pairs.

Service processor

The service processor (SVP) provides out‑of‑band configuration and management of the storage system, and collects performance data for key components to enable diagnostic testing and analysis. The SVP operates independently from the storage system's CPU and operating system.

The SVP is available as a physical device or as a software application.

The physical SVP is supplied by Hitachi Vantara and runs Windows Embedded Standard 7. When shipped in the Hitachi Universal V2 rack, the physical SVP is installed above the controller and drive trays. The Hitachi-supplied SVP can be configured to operate in a bridged or non-bridged network environment.

The SVP software application can run one of the following 64-bit operating systems on customer-supplied server hardware, a VMware ESXi host, or a Linux KVM host:

  • Windows 7 Professional x64 Service Pack 1
  • Windows 10 Professional
  • Windows 10 Enterprise
  • Windows Server 2012
  • Windows Server 2012 R2

The SVP software application can also run a customer-supplied version of Microsoft Hyper-V Server 2012 R2 on one of the following 64-bit operating systems:

  • Windows 10 Professional
  • Windows 10 Enterprise
  • Windows Server 2012
  • Windows Server 2012 R2

VSP G200VSP G400, G600 VSP G800 VSP F400, F600 VSP F800 storage system components

The VSP G200VSP G400, G600 VSP G800 VSP F400, F600 VSP F800 includes essential building blocks such as controllers, drive trays, and other optional front and back end components.

Replacement parts

Part replacement is essential for maintaining the high performance of the system. Replacing system components is covered by the maintenance service contract.

Battery unit

Replacement period

Three years.

Treatment

Use the storage system in a place where the ambient temperature is 86°F (30°C) or less on average.

Periodic parts replacement is required. For customers with maintenance service contracts, parts are replaced periodically in keeping with the terms of the contract.

NoteThe battery is designed to protect the data in the cache memory in an emergency, such as a sudden power failure. In these situations, follow the normal power down procedure. If not, the battery might reach its lifespan earlier than expected and become unusable within three years. When replacing the battery, follow the given procedure for disposing a used battery.

VSP G200VSP G400, G600 VSP G800 VSP F400, F600 VSP F800 storage system mechanical specifications

The storage system mechanical specifications are described for VSP G200 VSP G400, G600 VSP G800 VSP F400, F600 VSP F800.

VSP G200 mechanical specifications (AC power supply model)

Configuration
  • Controller

    1 CBSS

    1 CBSL

  • Drive trays

    1 SFF drive tray (DBS)

    1 LFF drive tray (DBL)

    1 FMD drive tray

    1 dense intermix drive tray

Drive

Item

Component

Specification

Drive size (WxDxH)

CBSS, SFF drive tray

2.5-type: 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm)

CBSL, LFF drive tray

3.5-type: 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm)

FMD drive tray

Flash module drive: 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm)

Data capacity (GB)

CBSS, SFF drive tray

2.5-type: 196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29, 1890.46

CBSL, LFF drive tray, dense intermix drive tray

3.5-type: 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36

FMD drive tray

Flash module drive: 1759.21, 3518.43 , 7036.87, 14073.74 GB

Rotational speed (min-1)

CBSS, SFF drive tray

Flash drive, 2.5-type: 196.92 GB, 393.85 GB
2.5-type: 288.20 GB, 15,000 RPM
2.5-type: 576.39 GB, 10,000 or 15,000 RPM
2.5-type: 1152.79 GB, 10,000 RPM
2.5-type: 1729.29 GB, 10,000 RPM
CBSL, LFF drive tray

Flash drive, 3.5-type: 393.85 GB
3.5-type: 1152.79 GB, 10,000 RPM
3.5-type: 1729.29 GB, 10,000 RPM
3.5-type: 3916.14 GB, 7,200  RPM
3.5-type: 5874.22 GB, 7,200 RPM
3.5-type: 9790.36 GB, 7,200 RPM

FMD drive tray

Flash module drive: 1759.21 GB, 3518.43 GB, 7036.87 GB, 14073.74 GB

Maximum number of drives that can be mounted

CBSS

24 drives

CBSL

12 drives

SFF drive tray (VSP Gx00 models only)

24 drives

LFF drive tray (VSP Gx00 models only)

12 drives

FMD drive tray

12 drives

Dense intermix drive tray (VSP Gx00 models only)

60 drives

Maximum number of spare drives

16

Host interface

Item

Component

Specification

Interface type

Fibre Channel optical

8-Gbps, 16-Gbps, 32-Gbps

iSCSI optical

10-Gbps

Copper iSCSI

10-Gbps

Data transfer speed (maximum speed for transfer to host)

Fibre Channel optical

800-Mbps (Fibre Channel)

Fibre Channel optical

1600-Mbps (Fibre Channel)

Fibre Channel optical

3200-Mbps (Fibre Channel)

iSCSI optical

10-Gbps (iSCSI optical)

Copper iSCSI

10-Gbps (copper iSCSI)

Number of ports

8-Gbps Fibre Channel optical

16

16-Gbps Fibre Channel optical (2-port)

8

16-Gbps Fibre Channel optical (4-port)

16

32-Gbps Fibre Channel optical

16

10-Gbps optical iSCSI

8

10-Gbps copper iSCSI

8

Transferred block size

512 bytes

Maximum number of hosts using a Fibre Channel switch

255

Maximum number of hosts using a network switch

255

Battery specifications

Storage system intake temperature CBSS CBSL

Up to 75.2º F (24º C)

5 years 5 years

Up to 86º F (30º C)

5 years 4 years

Up to 93.2º (34º C)

4 years 3 years

Up to 104º (40º C)

3 years 2 years
RAID specifications

D: Data drive, P: Parity drive.

Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.

Item

Drive tray

RAID Level

SAS, SAS 7.2k, flash drives mounted

RAID 1

2D+2D, 4D+4D

RAID 5

3D+1P, 4D+1P, 6D+1P, 7D+1P

RAID 6

6D+2P, 12D+2P, 14D+2P

Item

Specification

Maximum number of parity groups

88

Maximum volume size

3 TB (or 4 TB when using the LDEVs of other storage systems)

Maximum volumes/host groups and iSCSI targets

2,048

Maximum volumes/parity groups

2,048

Internal logic specifications

Item

Component

Specifications

Shared memory

Flash memory

32 MB

L3 cache memory

4 MB

SDRAM

1 GB

Data assurance method

Data bus

Parity

Cache memory

ECC (1 bit for correction, 2 bits for detection)

Drive

Data assurance code

Physical specifications

Item

Component

Specifications

Start-up time (min)1

Controller

Standard: 5 to 8

Drive trays

Standard: 5 to 8

Chassis size

Controller

WxDxH: 19 x 32 x 3.5 inches (483 x 813 x 88 mm)

SFF drive tray (VSP Gx00 models only)

WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm)

LFF drive tray (VSP Gx00 models only)

WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm)

FMD drive tray

WxDxH: 19 x 30 x 3.4 inches (483 x 762 x 87 mm)

Dense intermix drive tray (VSP Gx00 models only)

WxDxH: 19 x 40.5 x 7 inches (482 x 1029 x 176 mm)

Mass (approximate)2

CBSS

97 lbs (44 kg)
CBSL

101.4 lbs (46 kg)

SFF drive tray (VSP Gx00 models only)

51 lbs (23 kg)

LFF drive tray (VSP Gx00 models only)

59.5 lbs (27 kg)

FMD drive tray

84 lbs (38 kg)

Dense intermix drive tray (VSP Gx00 models only)

198 lbs (90 kg)

Required height

CBSS, CBSL 2

SFF drive tray (VSP Gx00 models only)

2

LFF drive tray (VSP Gx00 models only)

2

FMD drive tray

2

Dense intermix drive tray (VSP Gx00 models only)

4

Notes

  1. The startup time might be longer in proportion to the number of drive trays connected. With a maximum configuration of 1 controller and 19 drive trays, startup time is approximately 8 minutes.
  2. Value of maximum configuration when all controllers and drives are mounted.
  3. Mixing SFF, LFF, FMD, and dense intermix drive trays might affect the maximum number of drives that can be mounted.
  4. If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked.
Cache specifications

Item

Specifications

Capacity (GB)

64 GB

Control method

Read LRU, Write after

Battery backup

Provided

Backup duration

Unrestricted (saving to a nonvolatile memory)

Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.

When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.

When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.

The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.

If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.

Insulation performance

Item

Specifications

Insulation withstand voltage

AC 1,500 V (100 mA, 1 min)

Insulation resistance

DC 500 V, 10 M Ω or more

VSP G200 mechanical specifications (DC power supply model)

Configuration
  • Controller

    1 CBSSD

    1 CBSLD

  • Drive trays

    1 SFF drive tray (DBSD)

    1 LFF drive tray (DBLD)

Item

Component

Specification

Drive size (WxDxH)

CBSSD, SFF drive tray

2.5-type: 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm)

CBSLD, LFF drive tray

3.5-type: 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm)

Data capacity (GB)

CBSSD, SFF drive tray

2.5-type: 196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29, 1890.46

CBSLD, LFF drive tray

3.5-type: 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36

Rotational speed (min-1)

CBSSD, SFF drive tray

Flash drive, 2.5-type: 196.92 GB, 393.85 GB
2.5-type: 288.20 GB, 15,000 RPM
2.5-type: 576.39 GB, 10,000 or 15,000 RPM
2.5-type: 1152.79 GB, 10,000 RPM
2.5-type: 1729.29 GB, 10,000 RPM
CBSLD, LFF drive tray

Flash drive, 3.5-type: 393.85 GB
3.5-type: 1152.79 GB, 10,000 RPM
3.5-type: 1729.29 GB, 10,000 RPM
3.5-type: 3916.14 GB, 7,200  RPM
3.5-type: 5874.22 GB, 7,200 RPM
3.5-type: 9790.36 GB, 7,200 RPM

Maximum number of drives that can be mounted

CBSSD, SFF drive tray

24 drives

CBSLD, LFF drive tray

12 drives

Maximum number of spare drives

16

Battery specifications

Storage system intake temperature CBSS CBSL

Up to 75.2º F (24º C)

5 years 5 years

Up to 86º F (30º C)

5 years 4 years

Up to 93.2º (34º C)

4 years 3 years

Up to 104º (40º C)

3 years 2 years
Host interface

Item

Component

Specification

Interface type

Fibre Channel optical

8-Gbps, 16-Gbps, 32-Gbps

iSCSI optical

10-Gbps

Copper iSCSI

10-Gbps

Data transfer speed (maximum speed for transfer to host)

Fibre Channel optical

800-Mbps (Fibre Channel)

Fibre Channel optical

1600-Mbps (Fibre Channel)

Fibre Channel optical

3200-Mbps (Fibre Channel)

iSCSI optical

10-Gbps (iSCSI optical)

Copper iSCSI

10 Gbps (copper iSCSI)

Number of ports

8-Gbps Fibre Channel optical

16

16-Gbps Fibre Channel optical (2-port)

8

16-Gbps Fibre Channel optical (4-port)

16

32-Gbps Fibre Channel optical

16

10-Gbps optical iSCSI

8

10 Gbps copper iSCSI

8

Transferred block size

512 bytes

Maximum number of hosts using a Fibre Channel switch

255

Maximum number of hosts using a network switch

255

RAID specifications

D: Data drive, P: Parity drive.

Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.

Item

Drive tray

RAID Level

SAS, SAS 7.2k, flash drives mounted

RAID 1

2D+2D, 4D+4D

RAID 5

3D+1P, 4D+1P, 6D+1P, 7D+1P

RAID 6

6D+2P, 12D+2P, 14D+2P

Item

Specification

Maximum number of parity groups

88

Maximum volume size

3 TB (or 4 TB when using the LDEVs of other storage systems)

Maximum volumes/host groups and iSCSI targets

2,048

Maximum volumes/parity groups

2,048

Internal logic specifications

Item

Component

Specifications

Shared memory

Flash memory

32 MB

L3 cache memory

4 MB

SDRAM

1 GB

Data assurance method

Data bus

Parity

Cache memory

ECC (1 bit for correction, 2 bits for detection)

Drive

Data assurance code

Physical specifications

Item

Component

Specifications

Start-up time (min)1

Controller

Standard: 5 to 8

Drive trays

Standard: 5 to 8

Chassis size

Controller

WxDxH: 19 x 32 x 3.5 inches (483 x 813 x 88 mm)

SFF drive tray (VSP Gx00 models only)

WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm)

LFF drive tray (VSP Gx00 models only)

WxDxH: 19 x 22.2 x 3.5 inches (483 x 565 x 88.2 mm)

Mass (approximate)2

CBSSD

97 lbs (44 kg)
CBSLD

101.4 lbs (46 kg)

SFF drive tray (VSP Gx00 models only)

51 lbs (23 kg)

LFF drive tray (VSP Gx00 models only)

59.5 lbs (27 kg)

Required height

CBSSD, CBSLD 2

SFF drive tray (VSP Gx00 models only)

2

LFF drive tray (VSP Gx00 models only)

2

Notes

  1. The startup time might be longer in proportion to the number of drive trays connected. With a maximum configuration of 1 controller and 19 drive trays, startup time is approximately 8 minutes.
  2. Value of maximum configuration when all controllers and drives are mounted.
  3. Mixing DBSD and DBLD drive trays might affect the maximum number of drives that can be mounted.
  4. If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked.

Cache specifications

Item

Specifications

Capacity (GB)

64 GB

Control method

Read LRU, Write after

Battery backup

Provided

Backup duration

Unrestricted (saving to a nonvolatile memory)

Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.

When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.

When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.

The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.

If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.

Insulation performance

Item

Specifications

Insulation withstand voltage

AC 1,500 V (100 mA, 1 min)

Insulation resistance

DC 500 V, 10 M Ω or more

VSP G400 or VSP F400 and VSP G600 or VSP F600 mechanical specifications

Controller

1 CBLM

  • Drive tray

    1 SFF drive tray (VSP Gx00 models only)

    1 LFF drive tray (VSP Gx00 models only)

    1 FMD drive tray

    1 Dense intermix drive tray (VSP Gx00 models only)

NAS module

Item Description
NAS module

Optional component for block and file storage configuration

Drive size

Item Specification
2.5-inch drive (SFF) (VSP Gx00 models only) 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm)
3.5-inch drive (LFF and dense intermix drive tray) (VSP Gx00 models only) 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm)
Flash Module Drive (flash module drive tray) 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm)

Data capacity (GB)

2.5-inch drive (SFF) (VSP Gx00 models only) 196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29, 1890.46
3.5-inch drive (LFF and dense intermix drive tray) (VSP Gx00 models only) 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36
Flash Module Drive (flash module drive tray) 1759.21, 3518.43 , 7036.87, 14073.74

Rotational speed (min-1)

2.5-inch drive (SFF) (VSP Gx00 models only)

196.92/393.85 GB

2288.20 GB: 15,000 RPM

576.39 GB: 10,000 or 15,000 RPM

1152.79 GB: 10,000 RPM

1729.29 GB: 10,000 RPM

3.5-inch drive (LFF and dense intermix drive tray) (VSP Gx00 models only)

393.85 GB: Flash drive

1152.79 GB: 10,000 RPM

1729.29 GB: 10,000 RPM

3916.14 GB: 7,200 RPM

5874.22 GB: 7,200 RPM

9790.36 GB: 7,200 RPM

Maximum mountable quantity

Mixing SFF, LFF, FMD, and dense intermix drive trays might affect the maximum number of drives that can be mounted.

SFF (VSP Gx00 models only) 24
LFF (VSP Gx00 models only) 12
Flash module drive (flash module drive tray) (VSP Gx00 models only) 12
Dense intermix drive tray (VSP Gx00 models only) 60
Maximum number of flash module drives (VSP Fx00 models) VSP F400: 8 +1 spare drive

VSP F600 16 + 1 spare drive

Battery specifications

Storage system intake temperature CBLMCBLH

Up to 75.2º F (24º C)

5 years

Up to 86º F (30º C)

5 years

Up to 93.2º (34º C)

4 years

Up to 104º (40º C)

3 years

Host interface

Item

Component

Specification

Interface type

Fibre Channel optical

8-Gbps, 16-Gbps, 32-Gbps

iSCSI optical

10-Gbps

iSCSI copper

10-Gbps

NAS module

10-Gbps (Fibre Channel optical)

Data transfer speed (maximum speed for transfer to host)

Fibre Channel optical

800-Mbps (Fibre Channel)

1600-Mbps (Fibre Channel)

3200-Mbps (Fibre Channel)

iSCSI optical

10-Gbps (iSCSI optical)

iSCSI copper

10-Gbps (iSCSI copper)

NAS module (Fibre Channel)

1000 Mbs

Number of ports

8-Gbps Fibre Channel optical

64

16-Gbps Fibre Channel optical (2-port)

32

16-Gbps Fibre Channel optical (4-port)

64

32-Gbps Fibre Channel optical

64

10-Gbps optical iSCSI

32

10-Gbps copper iSCSI

32
Number of ports (NAS Module not installed)

8-Gbps Fibre Channel optical

64

56

16-Gbps Fibre Channel optical (2-port)

32

28

16-Gbps Fibre Channel optical (4-port)

64

56

32-Gbps Fibre Channel optical

64

56

10-Gbps optical iSCSI

32

28

10-Gbps copper iSCSI

32

28

Number of ports (NAS Module installed)

8-Gbps Fibre Channel optical

24

16-Gbps Fibre Channel optical (2-port)

12

16-Gbps Fibre Channel optical (4-port)

24

32-Gbps Fibre Channel optical

24

10-Gbps optical iSCSI

12

10-Gbps copper iSCSI

12

10-Gbps Fibre Channel optical

12

Transferred block size

512 bytes

Maximum number of hosts using a Fibre Channel switch

255

Maximum number of hosts using a network switch

255

RAID specifications

D: Data drive, P: Parity drive.

Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.

RAID Level

SAS, SAS 7.2k, flash drives mounted

RAID 1

2D+2D, 4D+4D

RAID 5

3D+1P, 4D+1P, 6D+1P, 7D+1P

RAID 6

6D+2P, 12D+2P, 14D+2P

Item

Specification

Maximum number of RAID groups

VSP G400 or VSP F400:160

VSP G600 or VSP F600:240

Maximum volume size

3 TB (or 4 TB when using the LDEVs of other storage systems)

Maximum volumes/host groups and iSCSI targets

2048

Maximum number of volumes per RAID group

2048

Shared memory and data assurance

Item Specification
Flash memory 32 MB
L3 Cache memory 4 MB
SDRAM 1 GB
Data bus Parity
Cache memory ECC (1 bit for correction, 2 bits for detection)
Drive Data assurance code

Start-up time

Item
Standard: 5-to-8 minutes.

The start-up time may be longer in proportion to the number of drive trays connected. With a maximum configuration 1 controller tray and 19 drive trays, start-up time is approximately 8 minutes.

Chassis size

Component

Specification (WxDxH)

CBLM 19.01 x 35.10 x 6.86 inches (483 x 891.7 x 174.3 mm)
SFF/LFF (VSP Gx00 models only) 18.97 x 22.24 x 3.47 inches (482 x 565 x 88.2 mm)
DBF 19.01 x 30 x 3.42 inches (483 x 762 x 87 mm)
Dense intermix drive tray (VSP Gx00 models only) 18.97 x 40.51 x 6.92 inches (482 x 1,029 x 176 mm)

(includes the depth of the cable-management arms)

Mass (value of maximum configuration when all controllers and drives are mounted)

Component

Specification

CBLM 187.39 pounds (85 kg)
SFF (VSP Gx00 models only) Approx 50.70 inches (23 kg)
LFF (VSP Gx00 models only) Approx 59.52 inches (27 kg)
DBF Approx. 83.77 pounds (38 kg)
Dense intermix drive tray (VSP Gx00 models only) Approx. 198.41 pounds (90 kg)

Required height

Component

Specification

CBLM 4 U
SFF (VSP Gx00 models only) 2 U
LFF (VSP Gx00 models only) 2 U
DBF 2 U
Dense intermix drive tray (VSP Gx00 models only) 4 U

If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked.

Cache specifications

Item

Specification

Capacity (GB)

VSP G400: 128

VSP G600: 256

VSP F400: 128

VSP F600: 256

NAS module Cache Capacity

DDR3 DIMM 8GB x 12 [Slot]

Note:

  • All 12 slots must be fully installed with DIMMs.
  • Each DIMM is replaceable when they fail.
  • The DIMM is not common and cannot be used with DKC DIMM.

Control method

Read LRU, Write after

Battery backup

Provided

Backup duration

Unrestricted (saving to a nonvolatile memory)

Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.

When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.

When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.

The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.

If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.

Insulation performance

Item

Specification

Insulation withstand voltage

AC 1,500 V (100 mA, 1 min)

Insulation resistance

DC 500 V, 10 M Ω or more

VSP G800VSP F800 mechanical specifications

Controller

1 CBLH

  • Drive tray

    1 SFF drive tray (VSP Gx00 models only)

    1 LFF drive tray (VSP Gx00 models only)

    1 FMD drive tray

    1 Dense intermix drive tray (VSP Gx00 models only)

NAS module

Item Description
NAS module

Optional component for block and file storage configuration

Drive size

Item Specification
2.5-inch drive (SFF) (VSP Gx00 models only) 3.21 x 8.10 x 0.74 inches (81.6 x 205.7 x 18.7 mm)
3.5-inch drive (LFF and dense intermix drive tray) (VSP Gx00 models only) 4 x 5.78 x 1.02 inches (101.6 x 147.0 x 26.1 mm)
Flash Module Drive (flash module drive tray) 5.74 x 14.44 x 0.78 inches (146 x 366.8 x 19.8 mm)

Data capacity (GB)

2.5-inch drive (SFF) (VSP Gx00 models only) 196.92, 288.20, 393.85, 576.39, 1152.79, 1729.29, 1890.46
3.5-inch drive (LFF and dense intermix drive tray) (VSP Gx00 models only) 393.85, 1152.79, 1729.29, 3916.14, 5874.22, 9790.36
Flash Module Drive (flash module drive tray) 1759.21, 3518.43 , 7036.87, 14073.74

Rotational speed (min-1)

2.5-inch drive (SFF) (VSP Gx00 models only)

196.92/393.85 G bytes

2288.20 GB: 15,000 RPM

576.39 GB: 10,000 or 15,000 RPM

1152.79 GB: 10,000 RPM

1729.29 GB: 10,000 RPM

3.5-inch drive (LFF and dense intermix drive tray) (VSP Gx00 models only)

393.85 G bytes: Flash drive

1152.79 G bytes: 10,000 RPM

1729.29 G bytes: 10,000 RPM

3916.14 G bytes: 7,200 RPM

5874.22 G bytes: 7,200 RPM

9790.36 G bytes: 7,200 RPM

Maximum mountable quantity

Mixing SFF, LFF, FMD, and dense intermix drive trays might affect the maximum number of drives that can be mounted.

SFF (VSP Gx00 models only) 24
LFF (VSP Gx00 models only) 12
Dense intermix drive tray (VSP Gx00 models only) 60
Flash module drive (flash module drive tray) (VSP Gx00 models only) 12
Maximum number of spare drives (VSP Gx00 models only) 64
Maximum number of flash module drives (VSP Fx00 models) 40
Maximum number of spare drives (VSP Fx00 models) 2

Battery specifications

Storage system intake temperature CBLMCBLH

Up to 75.2º F (24º C)

5 years

Up to 86º F (30º C)

5 years

Up to 93.2º (34º C)

4 years

Up to 104º (40º C)

3 years

Host interface

Item

Component

Specification

Interface type

Fibre Channel optical

8-Gbps, 16-Gbps, 32-Gbps

iSCSI optical

10-Gbps

iSCSI (Copper)

10-Gbps

NAS module

10 Gbps (Fibre Channel optical)

Data transfer speed (maximum speed for transfer to host)

Fibre Channel optical

800-Mbps (Fibre Channel)

1600-Mbps (Fibre Channel)

3200-Mbps (Fibre Channel)

iSCSI optical

10-Gbps (iSCSI optical)

iSCSI (Copper)

10 Gbps (iSCSI copper)

NAS module (Fibre Channel)

1000 Mbs

VSP G800 maximum number of ports

8 Gbps Fibre Channel (optical)

64

16 Gbps Fibre Channel (optical 2-port)

32

16 Gbps Fibre Channel (optical 4-port)

64

32 Gbps Fibre Channel (optical)

64

10 Gbps iSCSI optical)

32

10 Gbps iSCSI (copper)

32

VSP F800 maximum number of ports

8 Gbps Fibre Channel (optical)

48

16 Gbps Fibre Channel (optical)

24

32 Gbps Fibre Channel (optical)

48

10 Gbps iSCSI (optical)

24

10 Gbps iSCSI (copper)

24

Maximum number of ports (NAS module installed)

8 Gbps Fibre Channel (optical)

16

16 Gbps Fibre Channel (optical 2-port)

8

16 Gbps Fibre Channel (optical 4-port)

16

32 Gbps Fibre Channel (optical)

16

10 Gbps iSCSI (optical)

8

10 Gbps iSCSI (copper)

8

10 Gbps Fibre Channel (optical)

12

Maximum number of ports (NAS modules not installed)

8 Gbps Fibre Channel (optical)

80

16 Gbps Fibre Channel (optical 2-port)

40

16 Gbps Fibre Channel (optical 4-port)

80

32 Gbps Fibre Channel (optical)

80

10 Gbps iSCSI (optical)

40

10 Gbps iSCSI (copper)

40

Maximum number of ports (host port expansion chassis and NAS module installed)

8 Gbps Fibre Channel (optical)

32

16 Gbps Fibre Channel Optical (2-port)

16

16 Gbps Fibre Channel Optical (4-port)

32

32 Gbps Fibre Channel Optical (4-port)

32

10 Gbps iSCSI (optical)

16

10 Gbps iSCSI (copper)

16

10 Gbps Fibre Channel (optical)

12

Transferred block size

512 bytes

Maximum number of hosts using a Fibre Channel switch

255

Maximum number of hosts using a network switch

255

RAID specifications

D: Data drive, P: Parity drive.

Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides data reliability enhanced by redundancy, there is a chance that user data could be lost due to an unexpected host, storage system hardware, or software failure. Therefore, users are requested to back up all data.

RAID Level

SAS, SAS 7.2k, flash drives mounted

RAID 1

2D+2D, 4D+4D

RAID 5

3D+1P, 4D+1P, 6D+1P, 7D+1P

RAID 6

6D+2P, 12D+2P, 14D+2P

Item

Specification

Maximum number of RAID groups

480

Maximum number of RAID groups

480

Maximum volume size

3 TB (or 4 TB when using the LDEVs of other storage systems)

Maximum volumes/host groups and iSCSI targets

2048

Maximum volumes/parity groups

2048

Shared memory and data assurance

Item Specification
Flash memory 32 M bytes
L3 Cache memory 4 M bytes
SDRAM 1 G bytes
Data bus Parity
Cache memory ECC (1 bit for correction, 2 bits for detection)
Drive Data assurance code

Start-up time

Item
Standard: 5-to-10 minutes.

The start-up time may be longer in proportion to the number of drive trays connected. With a maximum configuration 1 controller tray and 19 drive trays, start-up time is approximately 10 minutes.

Chassis size

Component

Specification (WxDxH)

CBLH 19.01 x 35.10 x 6.86 inches (483 x 891.7 x 174.3 mm)
SFF/LFF (VSP Gx00 models only) 18.97 x 22.24 x 3.47 inches (482 x 565 x 88.2 mm)
DBF 19.01 x 30 x 3.42 inches (483 x 762 x 87 mm)
Dense intermix drive tray (VSP Gx00 models only) 18.97 x 40.51 x 6.92 inches (482 x 1,029 x 176 mm)

(includes the depth of the cable-management arms)

Mass (value of maximum configuration when all controllers and drives are mounted)

Component

Specification

CBLH 187.39 pounds (85 kg)
SFF (VSP Gx00 models only) Approx 50.70 inches (23 kg)
LFF (VSP Gx00 models only) Approx 59.52 inches (27 kg)
DBF Approx. 83.77 pounds (38 kg)
Dense intermix drive tray (VSP Gx00 models only) Approx. 198.41 pounds (90 kg)

Required height

Component

Specification

CBLH 4 U
SFF (VSP Gx00 models only) 2 U
LFF (VSP Gx00 models only) 2 U
DBF 2 U
Dense intermix drive tray (VSP Gx00 models only) 4 U

If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked.

Cache specifications

Item

Specification

Capacity (GB)

VSP G800: 512

VSP F800: 512

NAS module Cache Capacity

DDR3 DIMM 8GB x 12 [Slot]

Note

  • All 12 slots must be fully installed with DIMMs.
  • Each DIMM is replaceable when they fail.
  • The DIMM is not common and cannot be used with DKC DIMM.

Control method

Read LRU, Write after

Battery backup

Provided

Backup duration

Unrestricted (saving to a nonvolatile memory)

Data in the cache memory is preserved against power failures. If a power outage occurs, data in cache memory is written to drives.

When the storage system enters Cache Backup mode, the amber WARNING LED goes on to when the system starts. This warning indicates that the battery charge has dropped significantly and the remaining battery capacity is not sufficient; the storage system will continue operating with the Write Cache function disabled.

When the battery is charged, the warning indication disappears, and the storage system continues the operation in the Write Cache function.

The warning indication disappears within six hours. Even when the warning is shown, normal operation is assured in Write-Through. Read and write performance is lowered because the Write Cache function is disabled.

If the storage system is not charged for more than six months, the battery can become overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery more than 3 hours every six months.

Insulation performance

Item

Specification

Insulation withstand voltage

AC 1,500 V (100 mA, 1 min)

Insulation resistance

DC 500 V, 10 M Ω or more

Electrical specifications for VSP G200VSP G400, G600VSP G800VSP F400, F600VSP F800

The electrical specifications are described for the storage systems.

Electrical specifications

Item

Controller

Drive tray

Input voltage (operable voltage range) (V)

AC 100-120/200-240 +6%/-11%

SFF, LFF, FMD, and dense intermix drive tray: AC 200-240 +6%/-11%

Input voltage (operable voltage range) (V)

AC 200-240 +6%/-11%

SFF, LFF, FMD, and dense intermix drive tray: AC 200-240 +6%/-11%

Frequency (Hz) 50/60 ±1
Number of phases, cabling Single-phase with protective grounding
Steady-state current 100V/200V1, 2

CBSS: 4.0x2/2.0x2

CBSL: 4.0x2/2.0x2

CBLM: 4.0x2

CBLH: 4.0x2

SFF drive tray: 2.4x2/1.2x2

LFF drive tray: 1.9x2/1.0x2

FMD drive tray: 2.6x2/1.3x2

Dense intermix drive tray: -/3.0x2

Current rating of breaker/fuse (A) 16.0 (each electrical)
Heat value (normal) (kJ/h)

CBSS: 1800 or less

CBSL 1550 or less

CBLM: 2160 or less

2810 or less

SFF drive tray: 1120 or less

LFF drive tray: 940 or less

FMD drive tray: 1300/1520 or less

FMD drive tray: 1520 or less

FMD drive tray: 1520 or less

Dense intermix drive tray: 3460 or less

Steady-state power (VA/W)3

CBSS: 800/760 or less

CBSL: 800/760 or less

CBLM: 1600/1560 or less

CBLH: 1600/1560 or less

SFF drive tray: 480/460 or less

LFF drive tray: 380/350 or less

FMD drive tray: 520/490 or less

Dense intermix drive tray: 1200/1160 or less

Power consumption (VA/W)

CBSS: 520/500 or less

CBSL: 450/430 or less

CBLM: 640/600 or less

CBLH: 840/780 or less

SFF drive tray: 320/310 or less

LFF drive tray: 280/260 or less

FMD drive tray: 440/420 or less

Dense intermix drive tray: 1000/960 or less

Notes:

  1. The power current of Nx2 described in this table is required for a single power unit.
  2. If one power unit fails, another power unit requires electric current for the two power units. Therefore, plan the power supply facility so that the current-carrying capacity for one power unit can provide the total capacity for two power units.
  3. This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included.

VSP G200 electrical specifications (DC power supply)

Input power specifications

Item

CBSSD

CBSLD

DBSD

DBLD

Rated input voltage (v) DC -60 to -48
Input voltage fluctuation (v) DC -72 to -40
Input voltage instant fluctuation (v) DC -75 to -36
Inrush current (v) 35 (Ta = 25°C, in the range of rated input voltage, except when voltage fluctuates)
Input shape Connection by connector. Connect the terminal by the dedicated cable with terminal. Connector: Positronic Industries Inc., PCS Series
Heat value (kJ/h) 1800 1550 1120 940
Steady-state power (W) 760 760 460 350
Power consumption (W) 500 430 310 260
Input current (A) 15.9 15.9 9.6 7.3
UPS No connection
Remote adapter No connection

Environmental specifications for VSP G200VSP G400, G600VSP G800VSP F400, F600VSP F800

The environmental specifications are described for the storage systems.

Environmental specifications

Temperature

CautionThe following VSP Gx00/Fx00 storage system components are not supported in high-temperature environments. Do not operate the following components at temperatures of 40°C or higher:
  • DB60 dense drive tray
  • Hitachi provided service processor (SVP) server
  • First-generation FMDs (non-DC2 FMDs)

State

Controller

SFF, LFF drive trays

Dense intermix drive tray

Operating 50°F to 104°F (10°C to 40°C) 50°F to 104°F (10°C to 40°C) 50°F to 95°F (10°C to 35°C)
Non-operating 14°F to 122°F (-10°C to 50°C) 14°F to 122°F (-10°C to 50°C) 14°F to 122°F (-10°C to 50°C)
Transport, storage -22°F to 140°F (-30°C to 60°C) -22°F to 140°F (-30°C to 60°C) -22°F to 140°F (-30°C to 60°C)
Temperature change rate (°C/h) 10 or less

State

Controller

FMD drive trays

Operating 50°F to 104°F (10°C to 40°C) DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed: 50°F to 95°F (10°C to 35°C)
Operating 50°F to 104°F (10°C to 40°C) DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is installed: 50°F to 104°F (10°C to 40°C)
Non-operating 14°F to 122°F (-10°C to 50°C) 14°F to 95°F (-10°C to 35°C)
Transport, storage -22°F to 140°F (-30°C to 60°C) -22°F to 122°F (-30°C to 50°C)
Temperature change rate (°C/h) 10 or less
Humidity

State

Percentage

Operating 8 to 80
Non-operating 8 to 90
Transport, storage (%) 5 to 95
Maximum wet bulb temperature (°C) 29 (non-condensing)
Vibration

State

m/s2

Operating 2.5 or less

Within 5 seconds (resonance point: 10 Hz or less)

Non-operating 5.0 or less at 5 Hz to 300 Hz (no damage to product)

9.8 (1.0 G)

Within 5 seconds (resonance point: 10 Hz or less)

Transport (packed) 5.0 or less
Impact
State

m/s2

Operating 20 or less

(10 ms, half sine wave)

Non-operating 50 or less

(10 ms, half sine wave)

Transport (packed) 80 or less
Altitude

State

Controller

FMD drive

Operating (m)

3,000 (Environmental temperature: 10°C to 32°C)

900 (Environmental temperature: 10°C to 40°C)

3,000 (Environmental temperature 10°C to 32°C)

OR

900 (Environmental temperature: 10°C to 35°C) when DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed.

Operating (m)

3,000 (Environmental temperature: 10°C to 32°C)

900 (Environmental temperature: 10°C to 40°C)

3,000 (Environmental temperature: 10°C to 32°C)

OR

900 (Environmental temperature: 10°C to 40°C) when DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is installed.

Non-operating (m) -60 to 12,000 N/A

State

Controller

SFF and LFF drives

Dense intermix drive tray

Operating (m)

3,000 (Environmental temperature: 10°C to 32°C)

3,000 (Environmental temperature: 10°C to 32°C)

3,000 (Environmental temperature: 10°C to 28°C)

1,000 (Environmental temperature: 10°C to 35°C)

900 (Environmental temperature: 10°C to 40°C)

900 (Environmental temperature: 10°C to 40°C)

Non-operating (m) N/A
Atmosphere

Avoid areas exposed to corrosive gas and salty air.

Acoustic Noise
State

Controller

SFF, LFF

Dense intermix drive tray

Operating 60 dB (Environmental temperature 32°C or less)1 60 dB (Environmental temperature 32°C or less)1 71 dB (Environmental temperature 32°C or less)1, 2, 3, 4
Non-operating 55 dB 55 dB 71 dB (Environmental temperature 32°C or less)1, 2, 3, 4

Notes:

  1. The system's internal temperature controls the rotating speed of the fan module. Therefore, this standard value might be exceeded if the maximum load continues under high-temperature environment or if a failure occurs in the system.
  2. Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient temperature, drive configuration, and operating status. Maximum volume can reach 79 dB during maintenance procedure for a failed ENC or power supply.
  3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status.
  4. When accessing the dense intermix drive tray, do not work for long times at the rear of the rack.

State

Controller

FMD

Operating 60 dB (Environmental temperature 32°C or less)1 60 dB (Environmental temperature 32°C or less)1, 2, 3

(When accessing the dense intermix drive tray, do not work for long times at the rear of the rack.)

Non-operating 55 dB (Environmental temperature 32°C or less)1, 2, 3, 4 55 dB

Notes:

  1. The system's internal temperature controls the rotating speed of the fan module. Therefore, this standard value might be exceeded if the maximum load continues under high-temperature environment or if a failure occurs in the system.
  2. Sound pressure level (LA) changes from 66 dB or 75 dB, according to the ambient temperature, drive configuration, and operating status. Maximum volume can reach 79 dB during maintenance procedure for a failed ENC or power supply.
  3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status.

VSP G200 environmental specifications (DC power supply)

Item

CBSSD/CBSLD/DBSD/DBLD

Notes

Temperature Operating

41°F to 104°F

(5°C to 40°C)

Non-operating

23°F to 131°F

(-5 to 55°C) in 16 hours

Transport/storage)

-22°F to 140°F

(-30°C to 60°C)

Humidity Operating

5% to 85% (non-condensing)

Transportation/storage

5% to 95% (non-condensing)

Vibration Operating (m/s2)

2.5 or less (5 to 300 Hz)

Within 5 seconds

(Resonance point:10 Hz or less)

Non-operating (m/s2)

5.0 or less (5 to 300 Hz): No critical damage for product.

9.8 (1.0 G) Adopt fall-prevention safety measures.

Transport (packed) (m/s2)

5.0 or less

Impact Operating (m/s2)

20 or less

10 ms, half sine wave

Non-operating (m/s2)

50 or less

Transport (packed) (m/s2)

80 or less

Angle at which the storage system turns over

15° or less

To be measured when installed on leveling bolts.

Altitude Operating (m)

-60 to 1,800 above sea level

Environmental temperature: 41°F to 104°F (5°C to 40°C)

-1,800 to 4,000 above sea level

Environmental temperature: 41°F to 86°F (5°C to 30°C)

Atmosphere

No corrosive gas and salty air must be found.

Acoustic Noise Operating

60 dB

Environmental temperature: 89.6°F (32°C) or less

The system's internal temperature controls the rotating speed of the fan. Therefore, this standard value might be exceeded if the maximum load continues under high-temperature environment or if a system failure occurs.

Measured at the position 1.5 meter away from the storage system, at a height of 1.5 meters.

Standby

55 dB

iSCSI specifications

Item

Specification

Comments

iSCSI target function Supported N/A
iSCSI target function Supported TrueCopy® only
iSCSI ports 2 per interface board

VSP Gx00 models: Maximum 32 per iSCSI system

VSP Fx00 models: Maximum 24 per iSCSI system

Connection methods Direct and switch connections
Host connections 255 (maximum per iSCSI port) With Linux software initiator, the maximum number decreases.
Path failover HDLM1 Supports Microsoft MPIO (Multi Path I/O)
Link 10 Gbps SFP+ N/A
Transfer speed 10 Gbps N/A
Connector type LC N/A
Cable Optical OM3, OM2 MMF cable N/A
Network switch L2 or L3 switch Should comply with IEEE802.3ae
Switch cascading Maximum: 5 switches or fewer Minimum number of cascading switches is recommended.
MAC address Per port (fixed value) Factory setting: World Wide Unique value. Cannot be changed.
Maximum transfer unit (MTU) 1,500, 4,500, 9,000 bytes (Ethernet frame) Jumbo frame, MTU size greater than 1500
Link aggregation Not supported N/A
Tagged VLAN Supported N/A
IPv4 Supported N/A
IPv6 Supported

Note the following precautions:

  • When iSCSI Port IPv6 is set to Enabled, if the IPv6 global address is set to automatic, the address is determined by acquiring a prefix from an IPv6 router.

  • If the IPv6 router does not exist in the network, the address cannot be determined. As a result, an iSCSI connection might be delayed. When an iSCSI Port IPv6 is set to Enabled, verify the IPv6 router is connected to the same network, and then set IPv6 global address automatically.

Subnet mask Supported N/A
Gateway address Supported N/A
DHCP N/A N/A
DNS N/A N/A
Ping (ICMP ECHO) Transmit, Receive Supported N/A
IPsec2 N/A N/A
TCP port number 3260 Changeable among 1 to 65,535. Observe the following if changing values:
  • The setting of the corresponding host should also be changed to log in the new port number.
  • The new port number might conflict with other network communication or be filtered on some network equipment, preventing the storage system from communicating through the new port number.
iSCSI name Both iqn3 and eui4 types are supported The unique iqn value is automatically set when a target is made. iSCSI name is configurable.
Error recovery level 0 (zero) Error recovery by retrying from host. Does not support Level 1 and Level 2.
Header digest Supported Detects header error or data error with iSCSI communication. The storage system follows the host's digest setting. If digest is enabled, the performance degrades. The amount of the degradation depends on factors such as host performance of host and transaction pattern.
Data digest Supported
Maximum iSCSI connections at one time 255 per iSCSI port N/A
CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session.
Mutual (2-way) CHAP Supported (not available if connected to Linux software initiator) Authentication: login request is sent properly from host to storage.
CHAP user registration Max 512 users per iSCSI port N/A
iSNS Supported With iSNS (name service), a host can discover a target without knowing the target's IP address.

Note:

  1. JP1, HiCommand Dynamic Link Manager. Pass switching is achieved. Not supported on Windows Vista and Windows 7 operating systems.
  2. IP Security. Authentication and encryption of IP packets. The storage system does not support IPsec.
  3. iqn: iSCSI Qualified Name. The iqn consists of a type identifier, "iqn," a date of domain acquisition, a domain name, and a character string given by the individual who acquired the domain. Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar
  4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef

iSCSI standards

The following standards apply to the management, maintenance, and iSCSI data ports. To configure this system, use switches that comply with the following standards:

  • IEEE 802.1D STP
  • IEEE 802.1w RSTP
  • IEEE 802.3 CSMA/CD
  • IEEE 802.3u Fast Ethernet
  • IEEE 802.3z 1000 BASE-X
  • IEEE 802.1Q Virtual LANs
  • IEEE 802.3ad Dynamic LACP
  • IEEE 802.3ae 10 Gigabit Ethernet
  • RFC 768 UDP
  • RFC 783 TFTP
  • RFC 791 IP
  • RFC 793 TCP
  • RFC 1157 SNMP v1
  • RFC 1231 MIB II
  • RFC 1757 RMON
  • RFC 1901 SNMPv2

Regulatory compliance

This equipment has been tested and certified for compliance with the following standards.

Table 1: Country Specifications and Certifications

Standard

Specification

Product marking or logo

Country regulation

Electronic emission controls FCC part 15 Subpart B:2013 FCC USA and Canada
ICES-003 Issue 5:2012 ICES-003 USA and Canada
AS/NZS CISPR 22:2009+A1 RCM Australia and New Zealand
TP TC 020/2011 EAC Russia, Belarus, and Kazakhstan
CNS 13438 BSMI Taiwan
KN22 KC Korea
KN24 KC Korea
Electronic emission certifications EN5522: 2010 CE EU
EN5524: 2010 CE EU
EN61000-3.2:2006+A1+A2 CE EU
EN61000-3.3:2008 CE EU
Safety certifications UL and CSA 60950-1:2007 cTUVus USA and Canada
EN60950-1:2006+A1 TUV Germany
IEC60950-1:2005+A1 N/A All CB countries
IEC60950-1:2005+A1 S-Mark Argentina
TP TC 004/2011 EAC Russia
CNS 14336-1 BSMI Taiwan
EN60950-1:2006+A1 CE EU
Radio interference voluntary control VCCI V-3/2013.04 VCCI Japan

Table 2: Cryptography Standards and Certifications

Standard

Certification

Country regulation

Description

Federal Information Processing Standards (FIPS)

#2727 FIPS 140-2 Level 1, 2 Consolidated Validation Certificate

http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/1401val2016.htm

USA and Canada

Encryption back end module provides high-speed data at rest encryption.

Physical SVP specifications

The following sections describe the specifications for the physical SVP.

Service processor hardware specifications

The following table lists the hardware specifications for the service processor (SVP) provided by Hitachi Vantara.

CautionThe SVP is not supported in high-temperature environments. Do not operate it in locations where the temperature is 40°C or higher.

Item

Specification

Dimensions

Height: 1.7 inches (43 mm)

Width: 17.2 inches (437 mm)

Depth: 14.5 inches (369 mm)

Weight: 14 lbs (6.4 kg)

Processor

Celeron G1820 2.7-GHz 2M, 2C, 2T

  • Cores: 2

  • Instruction set: 64-bit

  • SmartCache: 2 MB

  • Maximum memory size: 32 GB

  • Memory types: DDR3-1333, DDR3L-1333 @ 1.5V

Memory

8-GB RAM DDR3

Hard drive

2 TB

Network interface card

x4 ports (on-board NIC) +

x1 IPMI (BMC) port

Fans

2 x 4-cm 4-pin PWM fans

Operating system

Windows Embedded Standard 7

Physical SVP environmental specifications

The following table lists the environmental specifications for the physical SVP supplied by Hitachi Vantara.

Item

Specification

Operating temperature

41°F ~ 95°F

(5°C ~ 35°C)

Non-operating temperature range

-40°F ~ 140°F

(-40°C ~ 60°C)

Operating relative humidity range

8% ~ 90% (non-condensing)

Non-operating relative humidity range

5% - 95% (non-condensing)

Physical SVP electrical specifications

The following table lists the electrical specifications for the physical SVP supplied by Hitachi Vantara.

Item

Specification

Rated AC voltage

100-240 V, 50-60 Hz, 4.2 - 1.8A

Power supply

350-Watt AC power supply with PFC

AC voltage

100-240 V, 50-60 Hz, 4.2 - 1.8 Amp

Power supply safety / EMC

  • USA - UL listed, FCC
  • Canada - CUL listed
  • Germany - TUV Certified
  • Europe/CE Mark
  • EN 60950/IEC 60950-Compliant

MFT p-code

Description

Watts

MBD-X10SLM+-LN4F-O

Single-socket H3 (LGA 1150) / 32-GB DDR3 ECC 1600 MHz / 6x SATA / 4x GbE

20

CSE-512F-350B

Two 350 W 3.5-inch internal drive bays

26.4

CM8064601483405

Intel Celeron G1820 2.7 Ghz 2M tray

53

0F11000

3.5-inch 25.4 mm 2 TB 32 MB 7200 RPM

9.1

KVR16E11S8

4 GB 1600 Mhz DIMM SR x8 with TS Kingston F

4.05

112.55 Watts total

VA is 140.69, with a 0.8 power factor.

NoteThe measurements are not kilo values.

Minimum requirements for installing the SVP software on customer-supplied server hardware

Hitachi Vantara allows the SVP software to be installed on customer-supplied servers that meet the following minimum requirements.

  • Processor:
    • One core with hyper-threading, two cores without hyper-threading
    • Processor performance comparable to Celeron 1.6 GHz
  • Random-access memory: 3.5 GB per storage system
  • Hard drive : 120 GB per storage system
  • LAN connection: one 1000Base-T
  • Operating system:
    • Windows 7 Professional x64 Service Pack 1 (64 bit)
    • Windows 10 Professional (64 bit)
    • Windows 10 Enterprise (64 bit)
    • Windows Server 2012 (64 bit)
    • Windows Server 2012 R2 (64 bit)

Virtual SVP requirements

The virtual SVP must meet the following minimum requirements.

ESX Server (provided by the customer)

  • VMware ESXi server 6.x
  • Two quad core processors, Intel Xeon 2.29 GHz
  • One port network interface card (NIC)
  • SVP guest OS
  • 32 GB RAM

SVP Guest OS (maximum one DKC per SVP guest OS)

  • Two virtual CPUs
  • One virtual network adapter
  • 4 GB RAM
  • 120 GB disk space
  • One of the following operating systems:
    • Windows 7 Professional x64 Service Pack 1 (64-bit)
    • Windows 10 Professional (64-bit)
    • Windows 10 Enterprise (64-bit)
    • Windows Server 2012 (64-bit)
    • Windows Server 2012 R2 (64-bit)

Miscellaneous

  • WinZip

Minimum requirements for a Linux KVM SVP

An SVP that will be used in a Linux KVM environment requires the following minimum requirements.

Prerequisites

Linux KVM Server (provided by the customer)

  • Oracle Linux 7.x server
  • Two quad core processors, Intel Xeon 2.29 GHz
  • One-port NIC
  • SVP guest OS
  • 128-GB RAM

SVP Guest OS (1 DKC) (maximum 1 DKC per SVP guest OS)

  • Two vCPUs
  • One virtual network adapter
  • 4-GB RAM
  • 120-GB disk space
  • One of the following operating systems:
    • Windows 7 Professional x64 Service Pack 1 (64 bit)
    • Windows 10 Professional (64 bit)
    • Windows 10 Enterprise (64 bit)
    • Windows Server 2012 (64 bit)
    • Windows Server 2012 R2 (64 bit)

Miscellaneous

  • WinZip

Minimum requirements for Hyper-V Server 2012 R2 VM

A host that runs the SVP software on a customer-supplied Microsoft Hyper-V Server 2012 R2 VM requires the following minimum requirements.

  • Hyper-V Server Windows 2012R supplied by the customer
  • Two quad core processors, Intel Xeon 2.29 GHz

  • One-port NIC
  • SVP guest OS
  • 32-GB RAM

The SVP guest (1 DKC) (maximum one DKC per SVP guest OS)

  • Two vCPUs
  • One virtual network adapter
  • 4-GB RAM
  • 120-GB disk space
  • One of the following operating systems:
    • Windows 10 Professional (64 bit)
    • Windows 10 Enterprise (64 bit)
    • Windows Server 2008 R2 (64 bit)
    • Windows Server 2012 (64 bit)
    • Windows Server 2012 R2 (64 bit)

To use Hyper-V Manager successfully, you must first configure your hosts correctly. In particular, confirm that each host:

  • Is licensed for Windows 2012R2 OS.
  • Meets the shared storage requirements for Hyper-V Management.
  • Meets the networking requirements for Hyper-V Management.

 

  • Was this article helpful?