The Hitachi Virtual Storage Platform E990 (VSP E990) storage system is a high-performance, large-capacity data storage system utilizing all-flash NVMe solid-state drives. The storage system consists of a controller chassis, one or more NVMe drive boxes, and internal components such as fans and PCIe switches.

The NVMe architecture delivers consistent, low-microsecond latency which reduces the transaction costs of latency-critical applications and delivers predictable performance to optimize storage resources.

Key features

High performance
  • Multiple controller configuration distributes processing to each controller
  • High-speed processing facilitated by up to 1,024 GiB of cache
  • I/O processing speed increased by NVMe flash drives
  • High-speed front-end data transfer up to 3.2 GB/s for FC and 1 GB/s for iSCSI
  • Response times as low as 64 microseconds
  • Integrated with Hitachi Ops Center to improve IT operational efficiencies
High reliability
  • Service continuity by main components in redundant configuration
  • RAID 1, RAID 5, and RAID 6 support (RAID 6 including 14D+2P)
  • Data security by transferring data to cache flash memory at the time of a power outage
Scalability and versatility
  • Scalable capacity up to 2.88 PB (internal), 287 PB (external), and 5.8M IOPS
  • Heterogeneous connectivity supporting concurrent attachment to a variety of hosts, including VMware, Linux, UNIX, and Windows

Storage system specifications

The storage system offers superior performance, resiliency, and agility, featuring response times as low as 64 microseconds, all backed up with the industry’s first and most comprehensive 100% data availability guarantee. The following table lists the key operational and performance specifications for the storage system.

VSP E990 specifications

Item

Specification

System

Number of NVMe flash drives

Minimum

4

Maximum

96

RAID group configuration

RAID 6

  • 6D+2P
  • 12D+2P
  • 14D+2P
RAID 5

  • 3D+1P
  • 4D+1P
  • 6D+1P
  • 7D+1P
RAID 1

  • 2D+2D
  • 4D+4D

Maximum number of spare drives

8

Maximum number of volumes

65,280

Maximum storage system capacity (physical capacity)

30 TB 2.5-inch SSD used

2.49 PiB (2.8 PB)

Maximum external configuration

255 PiB (287 PB)

Memory

Cache memory capacity

256 GiB to 1,024 GiB

Storage interface

DKC-drive interface

NVMe/Dual Port

Data transfer rate

8 Gbps

Maximum number of back-end modules

8

Device interface

Supported channel types

  • Fibre Channel (shortwave, longwave)
  • iSCSI (optical)

Data transfer rate

Fibre Channel

up to 3.2 GB/s

iSCSI (Optical)

10 Gbps

Maximum number of front-end modules

16