You can use the SNMP failure trap reference to identify trap reference codes to see what section it affects and the alert levels.

SNMP failure trap reference codes

The following table lists and describes the SNMP failure trap reference codes.

Trap reference code

Section

Description

Alert level (Severity)

Host report1

SIM 22

SIM 23

SIM 13

18

00

00

Audit Log lost

DKC environment

MODERATE

Yes

1C

00

00

Detected a specific error code SSB

DKC environment

SERVICE

Yes

21

20

xx

Channel port blocking

DKC environment

MODERATE

Yes

21

30

xx

CHB blocking

DKC environment

MODERATE

Yes

21

40

xx

DKB blocking

DKC environment

MODERATE

Yes

21

53

xx

PECB blocking

DKC environment

MODERATE

Yes

21

54

xx

SWPK blocking

DKC environment

MODERATE

Yes

21

57

xx

PECB warning

DKC environment

MODERATE

Yes

21

80

xx

RIO path closed

DKC environment

MODERATE

Yes

21

90

xx

AL_PA value conflict

DKC environment

SERVICE

Yes

21

93

xx

Link failure1

DKC environment

SERIOUS

Yes

21

94

xx

Link failure2

DKC environment

SERIOUS

Yes

21

a8

xx

SFP wrong type

DKC environment

MODERATE

Yes

21

aa

xx

SFP TxFault

DKC environment

MODERATE

Yes

21

d0

xx

External storage system connection path blocking

DKC environment

MODERATE

Yes

21

d1

xx

External storage system connection path restore

DKC environment

SERVICE

Yes

21

d2

xx

External subsystem path response timeout

DKC environment

SERVICE

Yes

30

70

xx

CHK1A threshold over

Processor

SERVICE

Yes

30

71

xx

CHK1B threshold over

Processor

SERVICE

Yes

30

72

xx

CHK3 threshold over

Processor

SERVICE

Yes

30

73

xx

Processor blocking

Processor

MODERATE

Yes

30

75

xx

CFM Failure

Cache

MODERATE

Yes

30

76

xx

Incorrect SUM value of FM

Processor

SERVICE

Yes

30

77

xx

Processor memory temporary error

Processor

SERVICE

Yes

30

78

xx

BFM error

Processor

SERIOUS

Yes

30

80

xx

WCHK1 dump

Processor

MODERATE

Yes

38

8f

00

PS OFF impossible

PS(DKC)

MODERATE

Yes

38

9f

00

PS OFF impossible (Device reserved)

PS(DKC)

MODERATE

Yes

39

90

xx

Undefined Package is mounted

Processor

MODERATE

Yes

39

91

xx

V-R or serial number is inconsistent

Processor

MODERATE

Yes

39

93

xx

Replace failed

Processor

MODERATE

Yes

39

9d

xx

Injustice dc voltage control

DKC environment

MODERATE

Yes

39

9e

xx

Injustice CEMODE

DKC environment

MODERATE

Yes

39

9f

xx

Injustice CEDT

DKC environment

MODERATE

Yes

39

a0

00

The upper temperature limit was exceeded

DKC environment

SERVICE

Yes

39

b0

xx

MP patrol check error

DKC environment

SERVICE

Yes

3a

0x

xx

LDEV Blockade (Effect of microcode error)

Drive

MODERATE

Yes

3c

95

00

CHB/DKB Type disagreement

DKC environment

MODERATE

Yes

3c

96

00

No CHB mounted

Processor

MODERATE

Yes

41

00

00

Format complete (Normal end)

Drive

SERVICE

Yes

41

00

01

Format complete (Abnormal end)

Drive

SERVICE

Yes

41

00

02

Format complete (Partial abnormal end)

Drive

SERVICE

Yes

41

01

00

Quick Format finish

Drive

SERVICE

Yes

43

4x

xx

Drive media error2

Drive

SERVICE

Yes

43

bx

xx

Drive blockade (media)(with redundancy)2

Drive

SERIOUS

Yes

43

cx

xx

Drive blockade (media)(without redundancy)2

Drive

SERIOUS

Yes

45

1x

xx

Correction copy start2

Drive

SERVICE

Yes

45

2x

xx

Correction copy normal end2

Drive

SERVICE

Yes

45

3x

xx

Correction copy abnormal end2

Drive

SERIOUS

Yes

45

4x

xx

Correction copy discontinued2

Drive

SERVICE

Yes

45

5x

xx

Correction copy warning end2

Drive

SERVICE

Yes

46

1x

xx

Dynamic sparing start(Drive copy)2

Drive

SERVICE

Yes

46

2x

xx

Dynamic sparing normal end(Drive copy)2

Drive

SERVICE

Yes

46

3x

xx

Dynamic sparing abnormal end (Drive copy)2

Drive

MODERATE

Yes

46

4x

xx

Dynamic sparing discontinued (Drive copy)2

Drive

SERVICE

Yes

46

5x

xx

Dynamic Sparing(Drive Copy) warning end2

Drive

SERVICE

Yes

46

8x

xx

Collection Copy/Copyback disabled(drive replace)

Drive

MODERATE

Yes

47

dx

xx

Shadow Image Copy abnormal end

DKC environment

MODERATE

Yes

47

e7

00

Forcible suspend by SM volatile

DKC environment

MODERATE

Yes

47

ec

e7

Forcible suspend by SM volatile

DKC environment

MODERATE

Yes

47

fx

xx

Volume Migration abnormal end

DKC environment

MODERATE

Yes

49

10

00

Cache overload condition

Cache

SERVICE

Yes

4a

80

xx

Expander Micro Exchange failed

DKC environment

MODERATE

Yes

4b

3x

xx

Thin Image Option abnormal end

DKC environment

MODERATE

Yes

4c

1x

xx

PDEV Erase Start

Drive

SERVICE

Yes

4c

2x

xx

PDEV Erase Normal End

Drive

SERVICE

Yes

4c

3x

xx

PDEV Erase Abnormal End

Drive

SERVICE

Yes

4C

4x

xx

Flash module drive initialization failed

Drive

MODERATE

Yes

4d

1x

xx

Differential area blocking

Drive

SERIOUS

Yes

50

1x

xx

Drive temporary error

Drive

SERVICE

Yes

50

2x

xx

Drive media error

Drive

SERVICE

Yes

50

5x

xx

Flash module drive internal battery error (ORM)2

Drive

SERVICE

Yes

50

8x

xx

Flash module drive internal battery error2

Drive

MODERATE

Yes

50

bx

xx

Flash drive End of life2

Drive

SERVICE

Yes

50

cx

xx

Flash module drive End of life2

Drive

SERVICE

Yes

50

dx

xx

Flash module drive battery warning2

Drive

SERVICE

Yes

50

ex

xx

Flash module drive battery capacity shortage2

Drive

MODERATE

Yes

50

f0

00

Flash module drive micro-program version warning

Drive

MODERATE

Yes

60

1x

xx

Pool utilization threshold excess

DKC environment

MODERATE

Yes

60

2x

xx

Pool blocking

DKC environment

MODERATE

Yes

60

2f

fe

Pools blocking by SM volatile

DKC environment

MODERATE

Yes

60

30

00

SM Space Warning

DKC environment

MODERATE

Yes

60

4x

xx

Exceeded Threshold of actual pool use rate

DKC environment

MODERATE

Yes

60

5x

xx

Actual pool use rate reaches upper limit

DKC environment

MODERATE

Yes

60

6x

xx

Exceeded Fixed outage Threshold of pool use rate

DKC environment

MODERATE

Yes

61

00

01

Backup/restore SM Information failed (Backup)

SM

MODERATE

Yes

61

00

02

Backup/restore SM Information failed (Restore)

SM

MODERATE

Yes

62

0x

xx

The DP POOL Warning Threshold was exceeded

DKC environment

MODERATE

Yes

62

2x

xx

The DP POOL FULL

DKC environment

MODERATE

Yes

62

3x

xx

The DP POOL error is detected

DKC environment

MODERATE

Yes

62

3f

fe

DP Pools blocking by Shared Memory volatile

DKC environment

MODERATE

Yes

62

40

00

SM Full

DKC environment

MODERATE

Yes

62

50

00

DP pool threshold continues to be exceeded

DKC environment

MODERATE

Yes

62

6x

xx

The DP POOL Depletion threshold was exceeded

DKC environment

MODERATE

Yes

62

7x

xx

The DP POOL LDEV blockade

DKC environment

MODERATE

Yes

62

80

00

DP Protect attribute setting of DRU

DKC environment

SERVICE

Yes

62

9x

xx

Exceeded Warning Threshold of DP pool use rate

DKC environment

MODERATE

Yes

62

ax

xx

Actual DP pool use rate reaches upper limit

DKC environment

MODERATE

Yes

62

b0

00

Threshold of DP pool use rate remains exceeded

DKC environment

MODERATE

Yes

62

cx

xx

Exceeded Depletion Threshold of DP pool use rate

DKC environment

MODERATE

Yes

62

dx

xx

Exceeded Fixed outage Threshold of DP pool use rate

DKC environment

MODERATE

Yes

62

ex

xx

Exceeded DP pool depletion threshold for TI pairs

DKC environment

MODERATE

Yes

64

1x

xx

Tier relocation is not completed

DKC environment

SERVICE

Yes

66

01

00

No free encryption key

DKC environment

MODERATE

Yes

66

02

00

Remaining free encryption key warning

DKC environment

SERVICE

Yes

66

10

xx

Acquisition of encryption key from KMS failed

DKC environment

MODERATE

Yes

67

00

00

Warning for depletion of cache management devices

Cache

MODERATE

Yes

6800xx Dedupe and compression abnormality detectDKC environmentMODERATEYes

76

00

00

CUDG detected error

DKC environment

MODERATE

Yes

79

00

xx

BOOT detected error

DKC environment

MODERATE

Yes

7d

00

0x

GUM error

DKC environment

MODERATE

Yes

7d

01

0x

LAN error (Internal Network)

DKC environment

MODERATE

Yes

7d

02

0x

LAN error (CTL1-CTL2)

DKC environment

MODERATE

Yes

7d

03

0x

GUM AuditLog lost

DKC environment

MODERATE

Yes

7d

04

0x

GUM AuditLog Warning Threshold was exceeded

DKC environment

MODERATE

Yes

7d

05

0x

Notification of Alert failed

DKC environment

MODERATE

Yes

7d

06

xx

MP error

Processor

MODERATE

Yes

7d

07

xx

GUM security error detected

DKC environment

MODERATE

Yes

7d

08

xx

Failed to recover GUM configuration information

DKC environment

MODERATE

Yes

7d

09

00

DKC warning

Processor

SERIOUS

Yes

7d

0a

xx

GUM version warning

DKC environment

MODERATE

Yes

7f

f1

02

SI

DKC environment

SERVICE

No

7f

f1

04

TI

DKC environment

SERVICE

No

7f

f1

06

Volume Migration Pair

DKC environment

SERVICE

No

7f

f7

xx

The term of validity is over

DKC environment

MODERATE

Yes

7f

f8

xx

The capacity of validity is over

DKC environment

MODERATE

Yes

7f

f9

xx

The PP is invalid by assumption PP invalidity

DKC environment

MODERATE

Yes

7f

fa

00

Synchronization time failure

DKC environment

SERVICE

Yes

ac

50

xx

DB power off

PS(DKU)

MODERATE

Yes

ac

51

xx

DB power recovered

PS(DKU)

SERVICE

Yes

ac

60

00

DKC was set to power error mode

PS(DKC)

MODERATE

Yes

ac

61

00

DKC was released from power error mode

PS(DKC)

SERVICE

Yes

ac

62

00

Destaging startup normal

PS(DKC)

SERVICE

Yes

ac

63

00

Destaging startup failed

PS(DKC)

MODERATE

Yes

ac

80

0x

Server failure

DKC environment

SERIOUS

Yes

af

00

xx

Injustice JP Warning

DKC environment

MODERATE

Yes

af

10

xx

MP Temperature abnormality warning

DKC environment

MODERATE

Yes

af

11

xx

External temperature warning

DKC environment

MODERATE

Yes

af

12

xx

External temperature alarm

DKC environment

MODERATE

Yes

af

13

xx

Thermal monitor warning

DKC environment

MODERATE

Yes

af

20

xx

DKCPS warning

PS(DKC)

MODERATE

Yes

af

21

xx

DKCPS input voltage abnormality

PS(DKC)

MODERATE

Yes

af

30

xx

Environmental microcomputer warning

DKC environment

MODERATE

Yes

af

31

xx

Device movement mode warning

DKC environment

MODERATE

Yes

af

32

xx

Environmental Firmware Update warning

DKC environment

MODERATE

Yes

af

33

xx

Voltage change setting warning

PS(DKC)

MODERATE

Yes

af

40

xx

BKM/BKMF warning

DKC environment

MODERATE

Yes

af

41

xx

Battery replacement should be scheduled

Battery

MODERATE

Yes

af

42

xx

CHBB environmental microcontroller warning

DKC environment

MODERATE

Yes

af

43

xx

SCM environmental microcontroller warning

DKC environment

MODERATE

Yes

af

44

xx

CHBB environmental firmware update warning

DKC environment

MODERATE

Yes

af

45

xx

SCM environmental firmware update warning

DKC environment

MODERATE

Yes

af

46

xx

SWPK temperature warning

DKC environment

MODERATE

Yes

af

48

xx

CHBB voltage change failure warning

DKC environment

MODERATE

Yes

af

49

xx

SCM voltage change failure warning

DKC environment

MODERATE

Yes

af

4a

xx

CHBBPS warning

DKC environment

MODERATE

Yes

af

4b

xx

CHBBPS abnormal input voltage

DKC environment

MODERATE

Yes

af

4c

xx

CHBBFAN warning

DKC environment

MODERATE

Yes

af4d xx Panel switch warningDKC environmentMODERATEYes
af4exxInvalid PS ON warningDKC environmentMODERATEYes

af

50

xx

DBPS warning

PS(DKU)

MODERATE

Yes

af

60

xx

DBPS input voltage abnormality

PS(DKU)

MODERATE

Yes

af

70

00

DB External temperature warning

DKU environment

MODERATE

Yes

af

71

00

DB External temperature Alarm

DKU environment

MODERATE

Yes

af

80

xx

ENC warning

DKU environment

MODERATE

Yes

af

e4

xx

Life expiry warning for DB air filter

DKU environment

SERVICE

Yes

af

f0

xx

UPS warning

PS(DKC)

MODERATE

Yes

af

f1

xx

GUM warning

DKC environment

MODERATE

Yes

af

f2

xx

CFM error

Cache

MODERATE

Yes

af

f3

xx

FAN warning

Fan(DKC)

MODERATE

Yes

af

f4

00

Life expiry warning for DKC air filter

DKC environment

SERVICE

Yes

bf

c0

10

DKC ALARM LED light on

Processor

SERIOUS

Yes

cf

10

xx

SAS CTL blocking

DKC environment

MODERATE

Yes

cf

11

xx

SAS Port (WideLink) is partially blocked

DKC environment

SERVICE

Yes

cf

12

xx

SAS PORT BLOCK3

DKC environment

MODERATE

Yes

cf

13

xx

SAS-CTL Error detection

DKC environment

SERIOUS

Yes

cf

14

xx

Recovered from ENC temporary failure successfully3

DKC environment

SERVICE

Yes

cf

88

xx

CTL blocking

DKC environment

MODERATE

Yes

cf8axx CTL blockade due to CTL interconnect path failure

DKC environment

MODERATEYes

d0

0x

xx

Remote Copy start

DKC environment

SERVICE

Yes

d0

1x

xx

Remote Copy normal end

DKC environment

SERVICE

Yes

d0

2x

xx

Pair end

DKC environment

SERVICE

Yes

d1

0x

xx

HRC pair status change(MCU command), SMPL -> COPY

DKC environment

SERVICE

Yes

d1

1x

xx

HRC pair status change(MCU command), SMPL -> PAIR

DKC environment

SERVICE

Yes

d1

2x

xx

HRC pair status change(MCU command), COPY -> PAIR

DKC environment

SERVICE

Yes

d1

3x

xx

HRC pair status change(MCU command), COPY -> PSUx

DKC environment

SERVICE

Yes

d1

4x

xx

HRC pair status change(MCU command), PAIR -> PSUx

DKC environment

SERVICE

Yes

d1

5x

xx

HRC pair status change(MCU command), PAIR -> SMPL

DKC environment

SERVICE

Yes

d1

6x

xx

HRC pair status change(MCU command), COPY -> SMPL

DKC environment

SERVICE

Yes

d1

7x

xx

HRC pair status change(MCU command), PSUx -> SMPL

DKC environment

SERVICE

Yes

d1

8x

xx

HRC pair status change(MCU command), PSUx -> COPY

DKC environment

SERVICE

Yes

d1

9x

xx

HRC pair status change(MCU command), COPY -> PSUx

DKC environment

SERVICE

Yes

d1

ax

xx

HRC pair status change(MCU command), COPY -> PSUx

DKC environment

SERVICE

Yes

d1

bx

xx

HRC pair status change(MCU command), PSUx -> PSUx

DKC environment

SERVICE

Yes

d4

0x

xx

Pair suspend(RIO path closed)

DKC environment

SERIOUS

Yes

d4

1x

xx

Pair suspend(P-VOL error)

DKC environment

SERIOUS

Yes

d4

2x

xx

Pair suspend(S-VOL error)

DKC environment

SERIOUS

Yes

d4

4x

xx

Pair suspend(RVOL Suspend report)

DKC environment

SERIOUS

Yes

d4

5x

xx

Pair suspend(S-VOL Simplex report)

DKC environment

SERIOUS

Yes

d4

6x

xx

Pair suspend(Communication error at RCU)

DKC environment

SERIOUS

Yes

d4

7x

xx

Pair suspend(Error detected at RCU)

DKC environment

SERIOUS

Yes

d4

fx

xx

Pair status incorrect

DKC environment

SERIOUS

Yes

d8

0x

xx

Volume to be used by UR was defined

DKC environment

SERVICE

Yes

d8

1x

xx

Volume used by UR began copying

DKC environment

SERVICE

Yes

d8

2x

xx

Volume used by UR completed copying

DKC environment

SERVICE

Yes

d8

3x

xx

Volume used by UR received suspension request

DKC environment

SERVICE

Yes

d8

4x

xx

Volume used by UR completed suspension transaction

DKC environment

SERVICE

Yes

d8

5x

xx

Volume used by UR received request for deletion

DKC environment

SERVICE

Yes

d8

6x

xx

Volume used by UR completed deletion

DKC environment

SERVICE

Yes

d8

7x

xx

Volume used by UR was defined

DKC environment

SERVICE

Yes

d8

8x

xx

Volume used by UR was defined in hold

DKC environment

SERVICE

Yes

d8

9x

xx

PVOL used by UR was defined in hold

DKC environment

SERVICE

Yes

d9

0x

xx

Change to SVOL was received from MCU, SMPL -> COPY

DKC environment

SERVICE

Yes

d9

1x

xx

Change to SVOL was received from MCU, SMPL -> PAIR

DKC environment

SERVICE

Yes

d9

2x

xx

Change to SVOL was received from MCU, COPY -> PAIR

DKC environment

SERVICE

Yes

d9

3x

xx

Change to SVOL was received from MCU, COPY -> PSUx

DKC environment

SERVICE

Yes

d9

4x

xx

Change to SVOL was received from MCU, PAIR -> PSUx

DKC environment

SERVICE

Yes

d9

5x

xx

Change to SVOL was received from MCU, PAIR -> SMPL

DKC environment

SERVICE

Yes

d9

6x

xx

Change to SVOL was received from MCU, COPY -> SMPL

DKC environment

SERVICE

Yes

d9

7x

xx

Change to SVOL was received from MCU, PSUx -> SMPL

DKC environment

SERVICE

Yes

d9

8x

xx

Change to SVOL was received from MCU, PSUx -> COPY

DKC environment

SERVICE

Yes

d9

9x

xx

Change to SVOL was received from MCU, HOLD -> PAIR

DKC environment

SERVICE

Yes

d9

ax

xx

Change to SVOL was received from MCU, HOLD -> COPY

DKC environment

SERVICE

Yes

d9

bx

xx

Change to SVOL was received from MCU, HOLD -> SMPL

DKC environment

SERVICE

Yes

d9

cx

xx

Change to SVOL was received from MCU, SMPL -> PSUx

DKC environment

SERVICE

Yes

d9

dx

xx

Change to SVOL was received from MCU, SMPL -> HOLD

DKC environment

SERVICE

Yes

d9

ex

xx

Change to SVOL was received from MCU, PSUx -> HOLD

DKC environment

SERVICE

Yes

d9

fx

xx

Change to SVOL was received from MCU, PAIR -> COPY

DKC environment

SERVICE

Yes

da

0x

xx

Change to SVOL was received from RCU, SUSPEND REQ.

DKC environment

SERVICE

Yes

da

1x

xx

Change to SVOL was received from RCU, SUSPEND END

DKC environment

SERVICE

Yes

da

2x

xx

Change to SVOL was received from RCU, PSUx -> SMPL

DKC environment

SERVICE

Yes

da

3x

xx

Change to SVOL was received from RCU, COPY -> SMPL

DKC environment

SERVICE

Yes

da

4x

xx

Change to SVOL was received from RCU, PAIR -> SMPL

DKC environment

SERVICE

Yes

da

5x

xx

Change to SVOL was received from RCU, DELETING END

DKC environment

SERVICE

Yes

da

6x

xx

Change to SVOL was received from RCU, HOLD -> SMPL

DKC environment

SERVICE

Yes

dc

0x

xx

Pair suspend(RIO path closed)

DKC environment

SERIOUS

Yes

dc

1x

xx

Pair suspend(M-VOL error)

DKC environment

SERIOUS

Yes

dc

2x

xx

Pair suspend(R-VOL error)

DKC environment

SERIOUS

Yes

dc

4x

xx

Pair suspend(Suspend report)

DKC environment

SERIOUS

Yes

dc

5x

xx

Pair suspend(Simplex report)

DKC environment

SERIOUS

Yes

dc

6x

xx

Pair suspend(Communication error at RCU)

DKC environment

SERIOUS

Yes

dc

7x

xx

Pair suspend(Error detected at RCU)

DKC environment

SERIOUS

Yes

dc

8x

xx

Pair suspend(MCU P/S OFF)

DKC environment

SERVICE

Yes

dc

9x

xx

Pair suspend(Delta volume error)

DKC environment

SERIOUS

Yes

dc

ax

xx

Pair suspend(Spread by error of another affiliate)

DKC environment

SERIOUS

Yes

dc

e0

xx

UR M-JNL Meta overflow warning

DKC environment

MODERATE

Yes

dc

e1

xx

UR M-JNL Data overflow warning

DKC environment

MODERATE

Yes

dc

e2

xx

UR R-JNL Meta overflow warning

DKC environment

MODERATE

Yes

dc

e3

xx

UR R-JNL Data overflow warning

DKC environment

MODERATE

Yes

dc

f0

xx

HUR read JNL was interrupted for 1 minute (at MCU)

DKC environment

MODERATE

Yes

dc

f1

xx

HUR read JNL was interrupted for 5 minute (at MCU)

DKC environment

SERIOUS

Yes

dc

f2

xx

HUR read JNL was interrupted for 1 minute (at RCU)

DKC environment

MODERATE

Yes

dc

f3

xx

HUR read JNL was interrupted for 5 minute (at RCU)

DKC environment

SERIOUS

Yes

dc

f4

xx

URxUR M-JNL Meta full Warning

DKC environment

MODERATE

Yes

dc

f5

xx

URxUR M-JNL Data full Warning

DKC environment

MODERATE

Yes

dd

0x

xx

GAD for this volume was suspended (Due to an unrecoverable failure on the remote copy connections)

Failure with paired volumes

SERIOUS

Yes

dd

1x

xx

GAD for this volume was suspended (Due to a failure on the volume)

Failure with paired volumes

SERIOUS

Yes

dd

2x

xx

GAD for this volume was suspended (Due to an internal error condition detected)

Failure with paired volumes

SERIOUS

Yes

dd

3x

xx

Status of the P-VOL was not consistent with the S-VOL

Failure with paired volumes

SERIOUS

Yes

de

e0

xx

Quorum Disk Restore

Drive

SERVICE

Yes

de

f0

xx

Quorum Disk Blocked

Drive

SERIOUS

Yes

df

6x

xx

Drive port temporary error(Drive path: Boundary 0)2

Drive

SERVICE

Yes

df

7x

xx

Drive port temporary error(Drive path: Boundary 1)2

Drive

SERVICE

Yes

df

8x

xx

Drive port blockade(Drive path: Boundary 0)2

Drive

MODERATE

Yes

df

9x

xx

Drive port blockade(Drive path: Boundary 1)2

Drive

MODERATE

Yes

df

ax

xx

LDEV blockade(Path 0 / Drive port blockade)2

Drive

SERIOUS

Yes

df

bx

xx

LDEV blockade(Path 1 / Drive port blockade)2

Drive

SERIOUS

Yes

df

cx

xx

Drive Link Rate Abnormality (Path 0)2

Drive

SERVICE

Yes

df

dx

xx

Drive Link Rate Abnormality (Path 1)2

Drive

SERVICE

Yes

df

fx

xx

Response late Drive2

Drive

SERVICE

Yes

ef

0x

xx

Drive blockade (drive)(with redundancy)2

Drive

SERIOUS

Yes

ef

1x

xx

Drive blockade (drive)(without redundancy)2

Drive

SERIOUS

Yes

ef

2x

xx

Drive blockade(Effect of Drive Copy normal end)2

Drive

SERVICE

Yes

ef

4x

xx

Pinned slot

Drive

MODERATE

Yes

ef

5x

xx

External VOL Write Error

Drive

MODERATE

Yes

ef

9x

xx

LDEV blockade (Effect of drive blockade)2

Drive

SERIOUS

Yes

ef

ax

xx

Drive temporary error2

Drive

SERVICE

Yes

ef

cx

xx

Correction access occurred2

Drive

SERIOUS

Yes

ef

d0

00

External storage system connection device blockade

Drive

SERIOUS

Yes

ef

ex

xx

Reboot stopped due to much write pending data

Drive

SERVICE

Yes

ef

fc

xx

PCI cable connection error

DKC environment

MODERATE

Yes

ef

fd

xx

Expander failure

DKC environment

SERIOUS

Yes

ef

fe

xx

UNIT connection error

DKC environment

MODERATE

Yes

fe

00

00

Cache battery is being charged

Cache

SERIOUS

Yes

fe

01

00

End of Cache Write Through

Cache

SERVICE

Yes

fe

02

00

Start of Cache Write Through

Cache

MODERATE

Yes

fe

03

0x

CFM type error or CFM shortage

Cache

SERIOUS

Yes

fe

04

0x

Mounting Battery shortage

Battery

SERIOUS

Yes

ff

21

xx

LANB blocking

DKC environment

MODERATE

Yes

ff

4x

xx

Pinned slot

Cache

MODERATE

Yes

ff

5x

xx

External VOL Read Error

Drive

MODERATE

Yes

ff

c3

0x

Cache Package Blockade Processing end

Cache

SERVICE

Yes

ff

cc

xy

CFM patrol check error

Cache

MODERATE

Yes

ff

cd

0x

Area is volatilized

Cache

SERVICE

Yes

ff

cf

xx

Module group is volatilized

Cache

SERVICE

Yes

ff

d4

00

Hard implementation out of the definition

DKC environment

MODERATE

Yes

ff

e2

0x

SM area blocking

SM

SERIOUS

Yes

ff

e4

0x

Replace failed

SM

SERIOUS

Yes

ff

e7

00

Shared memory is volatiled

SM

SERIOUS

Yes

ff

e8

00

Definition/Installation mismatch

Cache

ACUTE

Yes

ff

ea

0x

Recovery of area blocked temporarily was completed

SM

SERVICE

Yes

ff

ee

0x

Area temporary blocking

SM

SERVICE

Yes

ff

ef

00

Rebooted without volatilization

SM

SERVICE

Yes

ff

f0

xx

Cache correctable error

Cache

SERVICE

Yes

ff

f4

00

Area blocking

Cache

SERIOUS

Yes

ff

f5

0x

Both area failed

Cache

MODERATE

Yes

ff

f7

xx

GUM blocking

DKC environment

MODERATE

Yes

ff

f9

0x

Replace failed

Cache

SERVICE

Yes

ff

fa

xx

Battery warning

Battery

MODERATE

Yes

ff

fe

xx

Warning for forcible volatile mode

DKC environment

MODERATE

Yes

Legend:

  • YesThis SIM performs the host report.
  • NoThis SIM does not perform the host report.
  • x: A hexadecimal number from 0 to f.
  1. If you select All for Notification Alert in the Set Up Alert Notifications window, the SNMP agent reports all SIMs. If you select Host Report, the SNMP agent reports only SIMs that perform the host report.
  2. xxx: The right-hand digit of SIM 23 and both digits of SIM 13 can be converted to the number of the drive box and drive where the error occurred. For details, see Obtaining drive box and drive numbers.
  3. "Recovered from ENC temporary failure successfully" (cf14xx) indicates that "SAS PORT BLOCK" (cf12xx) occurred due to a temporary failure of ENC at the location indicated by the SAS-PORT number (xx) was recovered automatically. Therefore, no action by service personnel is required. However, if the SAS-PORT number indicated by SAS PORT BLOCK (cf12xx) is different from the one in cf14xx, action must be taken by service personnel.

Obtaining drive box and drive numbers

For certain trap reference codes, the right-hand digit of SIM 23 and both digits of SIM 13 form a three-digit hexadecimal number that can be converted to the number of the drive box and drive where the error occurred.

Procedure

  1. Combine the right-hand digit of SIM 23 and both digits of SIM 13 form a three-digit hexadecimal number.

  2. Convert the number in step 1 to decimal.

    For example, A9E in hexadecimal is 2,718 in decimal.
  3. Divide the the number in step 2 by 64. The quotient is the drive box number and the remainder is the drive number.

    For example, 2,718 / 64 = 42 with a remainder of 30. Therefore, The drive box number is 42 and the drive number is 30.
Examples

The following table provides examples of trap reference codes and their corresponding drive box and drive numbers.

Hexadecimal trap value Decimal value Decimal value / 64 Drive box number Drive number
Quotient Remainder
A9E 2,718 42 30 DB-42 HDD42-30
436 1,078 16 54 DB-16 HDD16-54
BFB 3,067 47 59 DB-47 HDD47-59