SNMP failure trap reference
You can use the SNMP failure trap reference to identify trap reference codes to see what section it affects and the alert levels.
SNMP failure trap reference codes
The following table lists and describes the SNMP failure trap reference codes.
Trap reference code | Section | Description | Alert level (Severity) | Host report1 | ||
SIM 22 | SIM 23 | SIM 13 | ||||
18 |
00 |
00 |
Audit Log lost |
DKC environment |
MODERATE |
Yes |
1C |
00 |
00 |
Detected a specific error code SSB |
DKC environment |
SERVICE |
Yes |
21 |
20 |
xx |
Channel port blocking |
DKC environment |
MODERATE |
Yes |
21 |
30 |
xx |
CHB blocking |
DKC environment |
MODERATE |
Yes |
21 |
40 |
xx |
DKB blocking |
DKC environment |
MODERATE |
Yes |
21 |
53 |
xx |
PECB blocking |
DKC environment |
MODERATE |
Yes |
21 |
54 |
xx |
SWPK blocking |
DKC environment |
MODERATE |
Yes |
21 |
57 |
xx |
PECB warning |
DKC environment |
MODERATE |
Yes |
21 |
80 |
xx |
RIO path closed |
DKC environment |
MODERATE |
Yes |
21 |
90 |
xx |
AL_PA value conflict |
DKC environment |
SERVICE |
Yes |
21 |
93 |
xx |
Link failure1 |
DKC environment |
SERIOUS |
Yes |
21 |
94 |
xx |
Link failure2 |
DKC environment |
SERIOUS |
Yes |
21 |
a8 |
xx |
SFP wrong type |
DKC environment |
MODERATE |
Yes |
21 |
aa |
xx |
SFP TxFault |
DKC environment |
MODERATE |
Yes |
21 |
d0 |
xx |
External storage system connection path blocking |
DKC environment |
MODERATE |
Yes |
21 |
d1 |
xx |
External storage system connection path restore |
DKC environment |
SERVICE |
Yes |
21 |
d2 |
xx |
External subsystem path response timeout |
DKC environment |
SERVICE |
Yes |
30 |
70 |
xx |
CHK1A threshold over |
Processor |
SERVICE |
Yes |
30 |
71 |
xx |
CHK1B threshold over |
Processor |
SERVICE |
Yes |
30 |
72 |
xx |
CHK3 threshold over |
Processor |
SERVICE |
Yes |
30 |
73 |
xx |
Processor blocking |
Processor |
MODERATE |
Yes |
30 |
75 |
xx |
CFM Failure |
Cache |
MODERATE |
Yes |
30 |
76 |
xx |
Incorrect SUM value of FM |
Processor |
SERVICE |
Yes |
30 |
77 |
xx |
Processor memory temporary error |
Processor |
SERVICE |
Yes |
30 |
78 |
xx |
BFM error |
Processor |
SERIOUS |
Yes |
30 |
80 |
xx |
WCHK1 dump |
Processor |
MODERATE |
Yes |
38 |
8f |
00 |
PS OFF impossible |
PS(DKC) |
MODERATE |
Yes |
38 |
9f |
00 |
PS OFF impossible (Device reserved) |
PS(DKC) |
MODERATE |
Yes |
39 |
90 |
xx |
Undefined Package is mounted |
Processor |
MODERATE |
Yes |
39 |
91 |
xx |
V-R or serial number is inconsistent |
Processor |
MODERATE |
Yes |
39 |
93 |
xx |
Replace failed |
Processor |
MODERATE |
Yes |
39 |
9d |
xx |
Injustice dc voltage control |
DKC environment |
MODERATE |
Yes |
39 |
9e |
xx |
Injustice CEMODE |
DKC environment |
MODERATE |
Yes |
39 |
9f |
xx |
Injustice CEDT |
DKC environment |
MODERATE |
Yes |
39 |
a0 |
00 |
The upper temperature limit was exceeded |
DKC environment |
SERVICE |
Yes |
39 |
b0 |
xx |
MP patrol check error |
DKC environment |
SERVICE |
Yes |
3a |
0x |
xx |
LDEV Blockade (Effect of microcode error) |
Drive |
MODERATE |
Yes |
3c |
95 |
00 |
CHB/DKB Type disagreement |
DKC environment |
MODERATE |
Yes |
3c |
96 |
00 |
No CHB mounted |
Processor |
MODERATE |
Yes |
41 |
00 |
00 |
Format complete (Normal end) |
Drive |
SERVICE |
Yes |
41 |
00 |
01 |
Format complete (Abnormal end) |
Drive |
SERVICE |
Yes |
41 |
00 |
02 |
Format complete (Partial abnormal end) |
Drive |
SERVICE |
Yes |
41 |
01 |
00 |
Quick Format finish |
Drive |
SERVICE |
Yes |
43 |
4x |
xx |
Drive media error2 |
Drive |
SERVICE |
Yes |
43 |
bx |
xx |
Drive blockade (media)(with redundancy)2 |
Drive |
SERIOUS |
Yes |
43 |
cx |
xx |
Drive blockade (media)(without redundancy)2 |
Drive |
SERIOUS |
Yes |
45 |
1x |
xx |
Correction copy start2 |
Drive |
SERVICE |
Yes |
45 |
2x |
xx |
Correction copy normal end2 |
Drive |
SERVICE |
Yes |
45 |
3x |
xx |
Correction copy abnormal end2 |
Drive |
SERIOUS |
Yes |
45 |
4x |
xx |
Correction copy discontinued2 |
Drive |
SERVICE |
Yes |
45 |
5x |
xx |
Correction copy warning end2 |
Drive |
SERVICE |
Yes |
46 |
1x |
xx |
Dynamic sparing start(Drive copy)2 |
Drive |
SERVICE |
Yes |
46 |
2x |
xx |
Dynamic sparing normal end(Drive copy)2 |
Drive |
SERVICE |
Yes |
46 |
3x |
xx |
Dynamic sparing abnormal end (Drive copy)2 |
Drive |
MODERATE |
Yes |
46 |
4x |
xx |
Dynamic sparing discontinued (Drive copy)2 |
Drive |
SERVICE |
Yes |
46 |
5x |
xx |
Dynamic Sparing(Drive Copy) warning end2 |
Drive |
SERVICE |
Yes |
46 |
8x |
xx |
Collection Copy/Copyback disabled(drive replace) |
Drive |
MODERATE |
Yes |
47 |
dx |
xx |
Shadow Image Copy abnormal end |
DKC environment |
MODERATE |
Yes |
47 |
e7 |
00 |
Forcible suspend by SM volatile |
DKC environment |
MODERATE |
Yes |
47 |
ec |
e7 |
Forcible suspend by SM volatile |
DKC environment |
MODERATE |
Yes |
47 |
fx |
xx |
Volume Migration abnormal end |
DKC environment |
MODERATE |
Yes |
49 |
10 |
00 |
Cache overload condition |
Cache |
SERVICE |
Yes |
4a |
80 |
xx |
Expander Micro Exchange failed |
DKC environment |
MODERATE |
Yes |
4b |
3x |
xx |
Thin Image Option abnormal end |
DKC environment |
MODERATE |
Yes |
4c |
1x |
xx |
PDEV Erase Start |
Drive |
SERVICE |
Yes |
4c |
2x |
xx |
PDEV Erase Normal End |
Drive |
SERVICE |
Yes |
4c |
3x |
xx |
PDEV Erase Abnormal End |
Drive |
SERVICE |
Yes |
4C |
4x |
xx |
Flash module drive initialization failed |
Drive |
MODERATE |
Yes |
4d |
1x |
xx |
Differential area blocking |
Drive |
SERIOUS |
Yes |
50 |
1x |
xx |
Drive temporary error |
Drive |
SERVICE |
Yes |
50 |
2x |
xx |
Drive media error |
Drive |
SERVICE |
Yes |
50 |
5x |
xx |
Flash module drive internal battery error (ORM)2 |
Drive |
SERVICE |
Yes |
50 |
8x |
xx |
Flash module drive internal battery error2 |
Drive |
MODERATE |
Yes |
50 |
bx |
xx |
Flash drive End of life2 |
Drive |
SERVICE |
Yes |
50 |
cx |
xx |
Flash module drive End of life2 |
Drive |
SERVICE |
Yes |
50 |
dx |
xx |
Flash module drive battery warning2 |
Drive |
SERVICE |
Yes |
50 |
ex |
xx |
Flash module drive battery capacity shortage2 |
Drive |
MODERATE |
Yes |
50 |
f0 |
00 |
Flash module drive micro-program version warning |
Drive |
MODERATE |
Yes |
60 |
1x |
xx |
Pool utilization threshold excess |
DKC environment |
MODERATE |
Yes |
60 |
2x |
xx |
Pool blocking |
DKC environment |
MODERATE |
Yes |
60 |
2f |
fe |
Pools blocking by SM volatile |
DKC environment |
MODERATE |
Yes |
60 |
30 |
00 |
SM Space Warning |
DKC environment |
MODERATE |
Yes |
60 |
4x |
xx |
Exceeded Threshold of actual pool use rate |
DKC environment |
MODERATE |
Yes |
60 |
5x |
xx |
Actual pool use rate reaches upper limit |
DKC environment |
MODERATE |
Yes |
60 |
6x |
xx |
Exceeded Fixed outage Threshold of pool use rate |
DKC environment |
MODERATE |
Yes |
61 |
00 |
01 |
Backup/restore SM Information failed (Backup) |
SM |
MODERATE |
Yes |
61 |
00 |
02 |
Backup/restore SM Information failed (Restore) |
SM |
MODERATE |
Yes |
62 |
0x |
xx |
The DP POOL Warning Threshold was exceeded |
DKC environment |
MODERATE |
Yes |
62 |
2x |
xx |
The DP POOL FULL |
DKC environment |
MODERATE |
Yes |
62 |
3x |
xx |
The DP POOL error is detected |
DKC environment |
MODERATE |
Yes |
62 |
3f |
fe |
DP Pools blocking by Shared Memory volatile |
DKC environment |
MODERATE |
Yes |
62 |
40 |
00 |
SM Full |
DKC environment |
MODERATE |
Yes |
62 |
50 |
00 |
DP pool threshold continues to be exceeded |
DKC environment |
MODERATE |
Yes |
62 |
6x |
xx |
The DP POOL Depletion threshold was exceeded |
DKC environment |
MODERATE |
Yes |
62 |
7x |
xx |
The DP POOL LDEV blockade |
DKC environment |
MODERATE |
Yes |
62 |
80 |
00 |
DP Protect attribute setting of DRU |
DKC environment |
SERVICE |
Yes |
62 |
9x |
xx |
Exceeded Warning Threshold of DP pool use rate |
DKC environment |
MODERATE |
Yes |
62 |
ax |
xx |
Actual DP pool use rate reaches upper limit |
DKC environment |
MODERATE |
Yes |
62 |
b0 |
00 |
Threshold of DP pool use rate remains exceeded |
DKC environment |
MODERATE |
Yes |
62 |
cx |
xx |
Exceeded Depletion Threshold of DP pool use rate |
DKC environment |
MODERATE |
Yes |
62 |
dx |
xx |
Exceeded Fixed outage Threshold of DP pool use rate |
DKC environment |
MODERATE |
Yes |
62 |
ex |
xx |
Exceeded DP pool depletion threshold for TI pairs |
DKC environment |
MODERATE |
Yes |
64 |
1x |
xx |
Tier relocation is not completed |
DKC environment |
SERVICE |
Yes |
66 |
01 |
00 |
No free encryption key |
DKC environment |
MODERATE |
Yes |
66 |
02 |
00 |
Remaining free encryption key warning |
DKC environment |
SERVICE |
Yes |
66 |
10 | xx |
Acquisition of encryption key from KMS failed |
DKC environment |
MODERATE |
Yes |
67 |
00 |
00 |
Warning for depletion of cache management devices |
Cache |
MODERATE |
Yes |
68 | 00 | xx | Dedupe and compression abnormality detect | DKC environment | MODERATE | Yes |
76 |
00 |
00 |
CUDG detected error |
DKC environment |
MODERATE |
Yes |
79 |
00 |
xx |
BOOT detected error |
DKC environment |
MODERATE |
Yes |
7d |
00 |
0x |
GUM error |
DKC environment |
MODERATE |
Yes |
7d |
01 |
0x |
LAN error (Internal Network) |
DKC environment |
MODERATE |
Yes |
7d |
02 |
0x |
LAN error (CTL1-CTL2) |
DKC environment |
MODERATE |
Yes |
7d |
03 |
0x |
GUM AuditLog lost |
DKC environment |
MODERATE |
Yes |
7d |
04 |
0x |
GUM AuditLog Warning Threshold was exceeded |
DKC environment |
MODERATE |
Yes |
7d |
05 |
0x |
Notification of Alert failed |
DKC environment |
MODERATE |
Yes |
7d |
06 |
xx |
MP error |
Processor |
MODERATE |
Yes |
7d |
07 |
xx |
GUM security error detected |
DKC environment |
MODERATE |
Yes |
7d |
08 |
xx |
Failed to recover GUM configuration information |
DKC environment |
MODERATE |
Yes |
7d |
09 |
00 |
DKC warning |
Processor |
SERIOUS |
Yes |
7d |
0a |
xx |
GUM version warning |
DKC environment |
MODERATE |
Yes |
7f |
f1 |
02 |
SI |
DKC environment |
SERVICE |
No |
7f |
f1 |
04 |
TI |
DKC environment |
SERVICE |
No |
7f |
f1 |
06 |
Volume Migration Pair |
DKC environment |
SERVICE |
No |
7f |
f7 |
xx |
The term of validity is over |
DKC environment |
MODERATE |
Yes |
7f |
f8 |
xx |
The capacity of validity is over |
DKC environment |
MODERATE |
Yes |
7f |
f9 |
xx |
The PP is invalid by assumption PP invalidity |
DKC environment |
MODERATE |
Yes |
7f |
fa |
00 |
Synchronization time failure |
DKC environment |
SERVICE |
Yes |
ac |
50 |
xx |
DB power off |
PS(DKU) |
MODERATE |
Yes |
ac |
51 |
xx |
DB power recovered |
PS(DKU) |
SERVICE |
Yes |
ac |
60 |
00 |
DKC was set to power error mode |
PS(DKC) |
MODERATE |
Yes |
ac |
61 |
00 |
DKC was released from power error mode |
PS(DKC) |
SERVICE |
Yes |
ac |
62 |
00 |
Destaging startup normal |
PS(DKC) |
SERVICE |
Yes |
ac |
63 |
00 |
Destaging startup failed |
PS(DKC) |
MODERATE |
Yes |
ac |
80 |
0x |
Server failure |
DKC environment |
SERIOUS |
Yes |
af |
00 |
xx |
Injustice JP Warning |
DKC environment |
MODERATE |
Yes |
af |
10 |
xx |
MP Temperature abnormality warning |
DKC environment |
MODERATE |
Yes |
af |
11 |
xx |
External temperature warning |
DKC environment |
MODERATE |
Yes |
af |
12 |
xx |
External temperature alarm |
DKC environment |
MODERATE |
Yes |
af |
13 |
xx |
Thermal monitor warning |
DKC environment |
MODERATE |
Yes |
af |
20 |
xx |
DKCPS warning |
PS(DKC) |
MODERATE |
Yes |
af |
21 |
xx |
DKCPS input voltage abnormality |
PS(DKC) |
MODERATE |
Yes |
af |
30 |
xx |
Environmental microcomputer warning |
DKC environment |
MODERATE |
Yes |
af |
31 |
xx |
Device movement mode warning |
DKC environment |
MODERATE |
Yes |
af |
32 |
xx |
Environmental Firmware Update warning |
DKC environment |
MODERATE |
Yes |
af |
33 |
xx |
Voltage change setting warning |
PS(DKC) |
MODERATE |
Yes |
af |
40 |
xx |
BKM/BKMF warning |
DKC environment |
MODERATE |
Yes |
af |
41 |
xx |
Battery replacement should be scheduled |
Battery |
MODERATE |
Yes |
af |
42 |
xx |
CHBB environmental microcontroller warning |
DKC environment |
MODERATE |
Yes |
af |
43 |
xx |
SCM environmental microcontroller warning |
DKC environment |
MODERATE |
Yes |
af |
44 |
xx |
CHBB environmental firmware update warning |
DKC environment |
MODERATE |
Yes |
af |
45 |
xx |
SCM environmental firmware update warning |
DKC environment |
MODERATE |
Yes |
af |
46 |
xx |
SWPK temperature warning |
DKC environment |
MODERATE |
Yes |
af |
48 |
xx |
CHBB voltage change failure warning |
DKC environment |
MODERATE |
Yes |
af |
49 |
xx |
SCM voltage change failure warning |
DKC environment |
MODERATE |
Yes |
af |
4a |
xx |
CHBBPS warning |
DKC environment |
MODERATE |
Yes |
af |
4b |
xx |
CHBBPS abnormal input voltage |
DKC environment |
MODERATE |
Yes |
af |
4c |
xx |
CHBBFAN warning |
DKC environment |
MODERATE |
Yes |
af | 4d | xx | Panel switch warning | DKC environment | MODERATE | Yes |
af | 4e | xx | Invalid PS ON warning | DKC environment | MODERATE | Yes |
af |
50 |
xx |
DBPS warning |
PS(DKU) |
MODERATE |
Yes |
af |
60 |
xx |
DBPS input voltage abnormality |
PS(DKU) |
MODERATE |
Yes |
af |
70 |
00 |
DB External temperature warning |
DKU environment |
MODERATE |
Yes |
af |
71 |
00 |
DB External temperature Alarm |
DKU environment |
MODERATE |
Yes |
af |
80 |
xx |
ENC warning |
DKU environment |
MODERATE |
Yes |
af |
e4 |
xx |
Life expiry warning for DB air filter |
DKU environment |
SERVICE |
Yes |
af |
f0 |
xx |
UPS warning |
PS(DKC) |
MODERATE |
Yes |
af |
f1 |
xx |
GUM warning |
DKC environment |
MODERATE |
Yes |
af |
f2 |
xx |
CFM error |
Cache |
MODERATE |
Yes |
af |
f3 |
xx |
FAN warning |
Fan(DKC) |
MODERATE |
Yes |
af |
f4 |
00 |
Life expiry warning for DKC air filter |
DKC environment |
SERVICE |
Yes |
bf |
c0 |
10 |
DKC ALARM LED light on |
Processor |
SERIOUS |
Yes |
cf |
10 |
xx |
SAS CTL blocking |
DKC environment |
MODERATE |
Yes |
cf |
11 |
xx |
SAS Port (WideLink) is partially blocked |
DKC environment |
SERVICE |
Yes |
cf |
12 |
xx |
SAS PORT BLOCK3 |
DKC environment |
MODERATE |
Yes |
cf |
13 |
xx |
SAS-CTL Error detection |
DKC environment |
SERIOUS |
Yes |
cf |
14 |
xx |
Recovered from ENC temporary failure successfully3 |
DKC environment |
SERVICE |
Yes |
cf |
88 |
xx |
CTL blocking |
DKC environment |
MODERATE |
Yes |
cf | 8a | xx | CTL blockade due to CTL interconnect path failure |
DKC environment | MODERATE | Yes |
d0 |
0x |
xx |
Remote Copy start |
DKC environment |
SERVICE |
Yes |
d0 |
1x |
xx |
Remote Copy normal end |
DKC environment |
SERVICE |
Yes |
d0 |
2x |
xx |
Pair end |
DKC environment |
SERVICE |
Yes |
d1 |
0x |
xx |
HRC pair status change(MCU command), SMPL -> COPY |
DKC environment |
SERVICE |
Yes |
d1 |
1x |
xx |
HRC pair status change(MCU command), SMPL -> PAIR |
DKC environment |
SERVICE |
Yes |
d1 |
2x |
xx |
HRC pair status change(MCU command), COPY -> PAIR |
DKC environment |
SERVICE |
Yes |
d1 |
3x |
xx |
HRC pair status change(MCU command), COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d1 |
4x |
xx |
HRC pair status change(MCU command), PAIR -> PSUx |
DKC environment |
SERVICE |
Yes |
d1 |
5x |
xx |
HRC pair status change(MCU command), PAIR -> SMPL |
DKC environment |
SERVICE |
Yes |
d1 |
6x |
xx |
HRC pair status change(MCU command), COPY -> SMPL |
DKC environment |
SERVICE |
Yes |
d1 |
7x |
xx |
HRC pair status change(MCU command), PSUx -> SMPL |
DKC environment |
SERVICE |
Yes |
d1 |
8x |
xx |
HRC pair status change(MCU command), PSUx -> COPY |
DKC environment |
SERVICE |
Yes |
d1 |
9x |
xx |
HRC pair status change(MCU command), COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d1 |
ax |
xx |
HRC pair status change(MCU command), COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d1 |
bx |
xx |
HRC pair status change(MCU command), PSUx -> PSUx |
DKC environment |
SERVICE |
Yes |
d4 |
0x |
xx |
Pair suspend(RIO path closed) |
DKC environment |
SERIOUS |
Yes |
d4 |
1x |
xx |
Pair suspend(P-VOL error) |
DKC environment |
SERIOUS |
Yes |
d4 |
2x |
xx |
Pair suspend(S-VOL error) |
DKC environment |
SERIOUS |
Yes |
d4 |
4x |
xx |
Pair suspend(RVOL Suspend report) |
DKC environment |
SERIOUS |
Yes |
d4 |
5x |
xx |
Pair suspend(S-VOL Simplex report) |
DKC environment |
SERIOUS |
Yes |
d4 |
6x |
xx |
Pair suspend(Communication error at RCU) |
DKC environment |
SERIOUS |
Yes |
d4 |
7x |
xx |
Pair suspend(Error detected at RCU) |
DKC environment |
SERIOUS |
Yes |
d4 |
fx |
xx |
Pair status incorrect |
DKC environment |
SERIOUS |
Yes |
d8 |
0x |
xx |
Volume to be used by UR was defined |
DKC environment |
SERVICE |
Yes |
d8 |
1x |
xx |
Volume used by UR began copying |
DKC environment |
SERVICE |
Yes |
d8 |
2x |
xx |
Volume used by UR completed copying |
DKC environment |
SERVICE |
Yes |
d8 |
3x |
xx |
Volume used by UR received suspension request |
DKC environment |
SERVICE |
Yes |
d8 |
4x |
xx |
Volume used by UR completed suspension transaction |
DKC environment |
SERVICE |
Yes |
d8 |
5x |
xx |
Volume used by UR received request for deletion |
DKC environment |
SERVICE |
Yes |
d8 |
6x |
xx |
Volume used by UR completed deletion |
DKC environment |
SERVICE |
Yes |
d8 |
7x |
xx |
Volume used by UR was defined |
DKC environment |
SERVICE |
Yes |
d8 |
8x |
xx |
Volume used by UR was defined in hold |
DKC environment |
SERVICE |
Yes |
d8 |
9x |
xx |
PVOL used by UR was defined in hold |
DKC environment |
SERVICE |
Yes |
d9 |
0x |
xx |
Change to SVOL was received from MCU, SMPL -> COPY |
DKC environment |
SERVICE |
Yes |
d9 |
1x |
xx |
Change to SVOL was received from MCU, SMPL -> PAIR |
DKC environment |
SERVICE |
Yes |
d9 |
2x |
xx |
Change to SVOL was received from MCU, COPY -> PAIR |
DKC environment |
SERVICE |
Yes |
d9 |
3x |
xx |
Change to SVOL was received from MCU, COPY -> PSUx |
DKC environment |
SERVICE |
Yes |
d9 |
4x |
xx |
Change to SVOL was received from MCU, PAIR -> PSUx |
DKC environment |
SERVICE |
Yes |
d9 |
5x |
xx |
Change to SVOL was received from MCU, PAIR -> SMPL |
DKC environment |
SERVICE |
Yes |
d9 |
6x |
xx |
Change to SVOL was received from MCU, COPY -> SMPL |
DKC environment |
SERVICE |
Yes |
d9 |
7x |
xx |
Change to SVOL was received from MCU, PSUx -> SMPL |
DKC environment |
SERVICE |
Yes |
d9 |
8x |
xx |
Change to SVOL was received from MCU, PSUx -> COPY |
DKC environment |
SERVICE |
Yes |
d9 |
9x |
xx |
Change to SVOL was received from MCU, HOLD -> PAIR |
DKC environment |
SERVICE |
Yes |
d9 |
ax |
xx |
Change to SVOL was received from MCU, HOLD -> COPY |
DKC environment |
SERVICE |
Yes |
d9 |
bx |
xx |
Change to SVOL was received from MCU, HOLD -> SMPL |
DKC environment |
SERVICE |
Yes |
d9 |
cx |
xx |
Change to SVOL was received from MCU, SMPL -> PSUx |
DKC environment |
SERVICE |
Yes |
d9 |
dx |
xx |
Change to SVOL was received from MCU, SMPL -> HOLD |
DKC environment |
SERVICE |
Yes |
d9 |
ex |
xx |
Change to SVOL was received from MCU, PSUx -> HOLD |
DKC environment |
SERVICE |
Yes |
d9 |
fx |
xx |
Change to SVOL was received from MCU, PAIR -> COPY |
DKC environment |
SERVICE |
Yes |
da |
0x |
xx |
Change to SVOL was received from RCU, SUSPEND REQ. |
DKC environment |
SERVICE |
Yes |
da |
1x |
xx |
Change to SVOL was received from RCU, SUSPEND END |
DKC environment |
SERVICE |
Yes |
da |
2x |
xx |
Change to SVOL was received from RCU, PSUx -> SMPL |
DKC environment |
SERVICE |
Yes |
da |
3x |
xx |
Change to SVOL was received from RCU, COPY -> SMPL |
DKC environment |
SERVICE |
Yes |
da |
4x |
xx |
Change to SVOL was received from RCU, PAIR -> SMPL |
DKC environment |
SERVICE |
Yes |
da |
5x |
xx |
Change to SVOL was received from RCU, DELETING END |
DKC environment |
SERVICE |
Yes |
da |
6x |
xx |
Change to SVOL was received from RCU, HOLD -> SMPL |
DKC environment |
SERVICE |
Yes |
dc |
0x |
xx |
Pair suspend(RIO path closed) |
DKC environment |
SERIOUS |
Yes |
dc |
1x |
xx |
Pair suspend(M-VOL error) |
DKC environment |
SERIOUS |
Yes |
dc |
2x |
xx |
Pair suspend(R-VOL error) |
DKC environment |
SERIOUS |
Yes |
dc |
4x |
xx |
Pair suspend(Suspend report) |
DKC environment |
SERIOUS |
Yes |
dc |
5x |
xx |
Pair suspend(Simplex report) |
DKC environment |
SERIOUS |
Yes |
dc |
6x |
xx |
Pair suspend(Communication error at RCU) |
DKC environment |
SERIOUS |
Yes |
dc |
7x |
xx |
Pair suspend(Error detected at RCU) |
DKC environment |
SERIOUS |
Yes |
dc |
8x |
xx |
Pair suspend(MCU P/S OFF) |
DKC environment |
SERVICE |
Yes |
dc |
9x |
xx |
Pair suspend(Delta volume error) |
DKC environment |
SERIOUS |
Yes |
dc |
ax |
xx |
Pair suspend(Spread by error of another affiliate) |
DKC environment |
SERIOUS |
Yes |
dc |
e0 |
xx |
UR M-JNL Meta overflow warning |
DKC environment |
MODERATE |
Yes |
dc |
e1 |
xx |
UR M-JNL Data overflow warning |
DKC environment |
MODERATE |
Yes |
dc |
e2 |
xx |
UR R-JNL Meta overflow warning |
DKC environment |
MODERATE |
Yes |
dc |
e3 |
xx |
UR R-JNL Data overflow warning |
DKC environment |
MODERATE |
Yes |
dc |
f0 |
xx |
HUR read JNL was interrupted for 1 minute (at MCU) |
DKC environment |
MODERATE |
Yes |
dc |
f1 |
xx |
HUR read JNL was interrupted for 5 minute (at MCU) |
DKC environment |
SERIOUS |
Yes |
dc |
f2 |
xx |
HUR read JNL was interrupted for 1 minute (at RCU) |
DKC environment |
MODERATE |
Yes |
dc |
f3 |
xx |
HUR read JNL was interrupted for 5 minute (at RCU) |
DKC environment |
SERIOUS |
Yes |
dc |
f4 |
xx |
URxUR M-JNL Meta full Warning |
DKC environment |
MODERATE |
Yes |
dc |
f5 |
xx |
URxUR M-JNL Data full Warning |
DKC environment |
MODERATE |
Yes |
dd |
0x |
xx |
GAD for this volume was suspended (Due to an unrecoverable failure on the remote copy connections) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
1x |
xx |
GAD for this volume was suspended (Due to a failure on the volume) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
2x |
xx |
GAD for this volume was suspended (Due to an internal error condition detected) |
Failure with paired volumes |
SERIOUS |
Yes |
dd |
3x |
xx |
Status of the P-VOL was not consistent with the S-VOL |
Failure with paired volumes |
SERIOUS |
Yes |
de |
e0 |
xx |
Quorum Disk Restore |
Drive |
SERVICE |
Yes |
de |
f0 |
xx |
Quorum Disk Blocked |
Drive |
SERIOUS |
Yes |
df |
6x |
xx |
Drive port temporary error(Drive path: Boundary 0)2 |
Drive |
SERVICE |
Yes |
df |
7x |
xx |
Drive port temporary error(Drive path: Boundary 1)2 |
Drive |
SERVICE |
Yes |
df |
8x |
xx |
Drive port blockade(Drive path: Boundary 0)2 |
Drive |
MODERATE |
Yes |
df |
9x |
xx |
Drive port blockade(Drive path: Boundary 1)2 |
Drive |
MODERATE |
Yes |
df |
ax |
xx |
LDEV blockade(Path 0 / Drive port blockade)2 |
Drive |
SERIOUS |
Yes |
df |
bx |
xx |
LDEV blockade(Path 1 / Drive port blockade)2 |
Drive |
SERIOUS |
Yes |
df |
cx |
xx |
Drive Link Rate Abnormality (Path 0)2 |
Drive |
SERVICE |
Yes |
df |
dx |
xx |
Drive Link Rate Abnormality (Path 1)2 |
Drive |
SERVICE |
Yes |
df |
fx |
xx |
Response late Drive2 |
Drive |
SERVICE |
Yes |
ef |
0x |
xx |
Drive blockade (drive)(with redundancy)2 |
Drive |
SERIOUS |
Yes |
ef |
1x |
xx |
Drive blockade (drive)(without redundancy)2 |
Drive |
SERIOUS |
Yes |
ef |
2x |
xx |
Drive blockade(Effect of Drive Copy normal end)2 |
Drive |
SERVICE |
Yes |
ef |
4x |
xx |
Pinned slot |
Drive |
MODERATE |
Yes |
ef |
5x |
xx |
External VOL Write Error |
Drive |
MODERATE |
Yes |
ef |
9x |
xx |
LDEV blockade (Effect of drive blockade)2 |
Drive |
SERIOUS |
Yes |
ef |
ax |
xx |
Drive temporary error2 |
Drive |
SERVICE |
Yes |
ef |
cx |
xx |
Correction access occurred2 |
Drive |
SERIOUS |
Yes |
ef |
d0 |
00 |
External storage system connection device blockade |
Drive |
SERIOUS |
Yes |
ef |
ex |
xx |
Reboot stopped due to much write pending data |
Drive |
SERVICE |
Yes |
ef |
fc |
xx |
PCI cable connection error |
DKC environment |
MODERATE |
Yes |
ef |
fd |
xx |
Expander failure |
DKC environment |
SERIOUS |
Yes |
ef |
fe |
xx |
UNIT connection error |
DKC environment |
MODERATE |
Yes |
fe |
00 |
00 |
Cache battery is being charged |
Cache |
SERIOUS |
Yes |
fe |
01 |
00 |
End of Cache Write Through |
Cache |
SERVICE |
Yes |
fe |
02 |
00 |
Start of Cache Write Through |
Cache |
MODERATE |
Yes |
fe |
03 |
0x |
CFM type error or CFM shortage |
Cache |
SERIOUS |
Yes |
fe |
04 |
0x |
Mounting Battery shortage |
Battery |
SERIOUS |
Yes |
ff |
21 |
xx |
LANB blocking |
DKC environment |
MODERATE |
Yes |
ff |
4x |
xx |
Pinned slot |
Cache |
MODERATE |
Yes |
ff |
5x |
xx |
External VOL Read Error |
Drive |
MODERATE |
Yes |
ff |
c3 |
0x |
Cache Package Blockade Processing end |
Cache |
SERVICE |
Yes |
ff |
cc |
xy | CFM patrol check error |
Cache |
MODERATE |
Yes |
ff |
cd |
0x |
Area is volatilized |
Cache |
SERVICE |
Yes |
ff |
cf |
xx |
Module group is volatilized |
Cache |
SERVICE |
Yes |
ff |
d4 |
00 |
Hard implementation out of the definition |
DKC environment |
MODERATE |
Yes |
ff |
e2 |
0x |
SM area blocking |
SM |
SERIOUS |
Yes |
ff |
e4 |
0x |
Replace failed |
SM |
SERIOUS |
Yes |
ff |
e7 |
00 |
Shared memory is volatiled |
SM |
SERIOUS |
Yes |
ff |
e8 |
00 |
Definition/Installation mismatch |
Cache |
ACUTE |
Yes |
ff |
ea |
0x |
Recovery of area blocked temporarily was completed |
SM |
SERVICE |
Yes |
ff |
ee |
0x |
Area temporary blocking |
SM |
SERVICE |
Yes |
ff |
ef |
00 |
Rebooted without volatilization |
SM |
SERVICE |
Yes |
ff |
f0 | xx |
Cache correctable error |
Cache |
SERVICE |
Yes |
ff |
f4 |
00 |
Area blocking |
Cache |
SERIOUS |
Yes |
ff |
f5 |
0x |
Both area failed |
Cache |
MODERATE |
Yes |
ff |
f7 |
xx |
GUM blocking |
DKC environment |
MODERATE |
Yes |
ff |
f9 |
0x |
Replace failed |
Cache |
SERVICE |
Yes |
ff |
fa |
xx |
Battery warning |
Battery |
MODERATE |
Yes |
ff |
fe |
xx |
Warning for forcible volatile mode |
DKC environment |
MODERATE |
Yes |
Legend:
|
Obtaining drive box and drive numbers
For certain trap reference codes, the right-hand digit of SIM 23 and both digits of SIM 13 form a three-digit hexadecimal number that can be converted to the number of the drive box and drive where the error occurred.
Procedure
Combine the right-hand digit of SIM 23 and both digits of SIM 13 form a three-digit hexadecimal number.
Convert the number in step 1 to decimal.
For example, A9E in hexadecimal is 2,718 in decimal.Divide the the number in step 2 by 64. The quotient is the drive box number and the remainder is the drive number.
For example, 2,718 / 64 = 42 with a remainder of 30. Therefore, The drive box number is 42 and the drive number is 30.
The following table provides examples of trap reference codes and their corresponding drive box and drive numbers.
Hexadecimal trap value | Decimal value | Decimal value / 64 | Drive box number | Drive number | |
Quotient | Remainder | ||||
A9E | 2,718 | 42 | 30 | DB-42 | HDD42-30 |
436 | 1,078 | 16 | 54 | DB-16 | HDD16-54 |
BFB | 3,067 | 47 | 59 | DB-47 | HDD47-59 |