Report examples: CSV files
Some Device Manager - Storage Navigator reports appear in CSV format. This topic describes reports that are saved in CSV format.
AllConf.csv
This is the concatenated file of all the csv files.
CacheInfo.csv
This CSV file contains information about the cache memory on the controller board. A record is created for each cache memory.
Item | Content |
Location | Name of the cache controller board on which the memory is installed. |
CMG#0 Size (GB) CMG#1 Size (GB) | Cache memory capacity in the controller board per CMG (32/64/128/256/blank). CMG#0 Size and CMG#1 Size are displayed. Depending on the installed number of cache memory (DIMMs), one of the CMG capacities might be blank. |
Cache Size (GB) | Total cache memory capacity on the controller board (0 to 512) |
SM Size (MB) | The capacity that cannot be used as data cache memory in the total cache memory capacity inside of the controller board:
The capacity per cluster is displayed. Includes the shared memory capacity, cache directory capacity, and the fixed capacity. Fixed capacity is the cache memory capacity that is used for controlling the storage system with the controller board. |
CFM#0 Type CFM#1 Type | Type of cache flash module (CFM) in the cluster: BM55, BM5E, BM65, BM6E, BM70, BM7E, blank. The number of CFM differs by model and the number of the displayed items are different. CFM#0 Type and CFM#1 Type are displayed. Depending on the installed CFM number, one of the CFM types might be displayed as blank. |
Unified Hypervisor Cache Size (GB) | Displayed only for VSP G/F700 and VSP G/F900. Zero (0) is displayed for other storage system models. |
ChapUserInfo.csv
This CSV file contains information about the iSCSI CHAP authenticated user registered to the port in the channel board. A record is created for each target related to the CHAP authenticated user.
Item |
Content |
Port |
Port name |
User Name |
Name of the CHAP authenticated user1 |
iSCSI Target ID2 |
The iSCSI number of the target (00 to fe, hexadecimal) |
Notes:
|
ChaStatus.csv
This CSV file contains information about the status of each channel board (CHB). A record is created for each CHB.
Item |
Content |
CHB Location |
CHB name |
PCB Status |
Status of this CHB* |
Port#00, #01, …, #03 |
Status of ports on this CHB* |
* 1: Normal, 0: Abnormal |
DeviceEquipInfo.csv
This CSV file contains information about equipment and devices that are part of the storage system, including DKC power supply, DB power supply, CHBB power supply, batteries, and BKMF. A record is created for each device.
Item | Content |
Device Location | Device location name. For example:
|
Equip Status | Equipment status of the device:
|
Status | Status of the device:
|
Type | (VSP E1090) Type of the device:
This item is blank if the device location name is not BKMF. This item is displayed only for VSP E1090. |
DkaInfo.csv
This CSV file contains information about disk boards (DKBs). A record is created for each DKB.
Item | Content |
DKB Location | DKB name |
Package Type | DKB type
The supported DKB types differ depending on the storage system model. |
DkaStatus.csv
This CSV file contains information about the status of disk boards (DKBs). A record is created for each DKB.
Item |
Content |
DKB Location |
DKB name |
PCB Status |
Status of this DKB1 |
BECON#00 |
Status of BECON1 |
BEPORT#0000 to #0001 |
Status of BEPORT on this DKB1 Items are output in the format BEPORT#XXYY, where:
|
Notes:
|
DkcInfo.csv
This CSV file contains information about the DKC. A record is created for each module.
When Module #1 is not installed, the record for Module #1 is not created.
Item | Content |
Storage System Type | Storage system type Output example: |
Serial Number # | Serial product number (decimal, from 400001 to 499999) |
IP Address | IP address Output example: |
Subnet Mask | Subnet mask Output example: |
Number of CUs | Number of CUs (decimal, 0 to 255) |
Number of DKBs | Number of DKBs (decimal, 0 to 8) Zero ( |
Configuration Type | Configuration type Output example: |
Model | Storage system model (for example, MH4) |
Unified Mode | Displayed only for VSP G/F700 and VSP G/F900.
|
DkuTempAveInfo.csv
DkuTempAveInfo.csv shows the average temperature as DB temperature data. The maximum number of items depends on the storage system model:
- VSP E590 and VSP E790 with DBS2: 21
- VSP E590 and VSP E790 without expansion drive box: 17
- VSP E990: 9
- VSP E1090 with DBS2: 73
- VSP E1090 with DBN: 9
- VSP E1090 without expansion drive box: 65
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only), DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output every two hours might not contain data for the period. If a failure occurs in the storage system, the correct information might not be output.
Item | Description |
Date | Year, month, and date when temperature data was acquired in the format: YYYY/MM/DD hh:mm:ss |
DB00 DBPS001 Temperature average | Average temperature (°C) for the two-hour period of DB00 DBPS001 |
DB47 DBPS472 Temperature average | Average temperature (°C) for the two-hour period of DB47 DBPS472 For VSP E590 andVSP E790, this item shows up to DB61 DBPS612. For VSP E990, this item shows up to DB03 DBPS032. For VSP E1090, this item shows up to DB69 DBPS692. |
Note: An item name is displayed as DBxx DBPSxxy. The names are listed in ascending order of the DB number. See DkuTempInfo.csv for locations and values for DBxx and DBPSxxy.
DkuTempInfo.csv
DkuTempInfo.csv shows the average temperature, maximum temperature, and minimum temperature as DB temperature data. The maximum number of items depends on the storage system model:
- VSP E590 and VSP E790 with DBS2: 61
- VSP E590 and VSP E790 without expansion drive box: 49
- VSP E990: 25
- VSP E1090 with DBS2: 217
- VSP E1090 with DBN: 25
- VSP E1090 without expansion drive box: 193
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only), DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output every two hours might not contain data for the period. If a failure occurs in the storage system, the correct information might not be output.
An item name is displayed as DBxx DBPSxxy. The names are listed in ascending order of the DB number.
Item | Description |
Date | Year, month, and date when temperature data was acquired in the format: YYYY/MM/DD hh:mm:ss |
DB00 DBPS001 Temperature average | Average temperature (°C) for the two-hour period of DB00 DBPS001 |
DB00 DBPS001 Temperature maximum value | Maximum temperature (°C) for the two-hour period of DB00 DBPS001 |
DB00 DBPS001 Temperature minimum value | Minimum temperature (°C) for the two-hour period of DB00 DBPS001 |
DB47 DBPS472 Temperature average | Average temperature (°C) for the two-hour period of DB47 DBPS472
|
DB47 DBPS472 Temperature maximum value | Maximum temperature (°C) for the two-hour period of DB47 DBPS472
|
DB47 DBPS472 Temperature minimum value | Minimum temperature (°C) for the two-hour period of DB47 DBPS472
|
The following tables list DBxx and DBPSxxy: xx values, where
- xx is a value from 00 to 61 for VSP E590 and VSP E790.
- xx is a value from 00 to 03 for VSP E990.
- xx is a value from 00 to 69 for VSP E1090.
DB # | 0 | 1 | 2 | … (omitted) | 46 | 47 |
xx | 00 | 01 | 02 | ... | 46 | 47 |
DBxx | DB00 | DB01 | DB02 | ... | DB46 | DB47 |
DBxxy | DBPS00y | DBPS01y | DBPS02y | ... | DBPS46y | DBPS47y |
The following table lists the DBPSxxy: y values (where DB# is 0 and xx is 00)
DB# | 0 | |
y | 1 | 2 |
DBPSxxy: y | DBPS001 | DBPS002 |
DkuTempMaxInfo.csv
DkuTempMaxInfo.csv shows the maximum temperature as DB temperature data. The maximum number of items depends on the storage system model:
- VSP E590 and VSP E790 with DBS2: 21
- VSP E590 and VSP E790 without expansion drive box: 17
- VSP E990: 9
- VSP E1090 with DBS2: 73
- VSP E1090 with DBN: 9
- VSP E1090 without expansion drive box: 65
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only), DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output every two hours might not contain data for the period. If a failure occurs in the storage system, the correct information might not be output.
An item name is displayed as DBxx DBPSxxy. The names are listed in ascending order of the DB number. See DkuTempInfo.csv for locations and values for DBxx and DBPSxxy..
Item | Description |
Date | Year, month, and date when temperature data was acquired in the format: YYYY/MM/DD hh:mm:ss |
DB00 DBPS001 Temperature maximum value | Maximum temperature (°C) for the two-hour period of DB00 DBPS001 |
DB47 DBPS472 Temperature maximum value | Maximum temperature (°C) for the two-hour period of DB47 DBPS472 For VSP E590 and VSP E790, this item shows up to DB61 DBPS612. For VSP E990, this item shows up to DB03 DBPS032. For VSP E1090, this item shows up to DB69 DBPS692. |
DkuTempMinInfo.csv
DkuTempMinInfo.csv shows the minimum temperature as DB temperature data. The maximum number of items depends on the storage system model:
- VSP E590 and VSP E790 with DBS2: 21
- VSP E590 and VSP E790 without expansion drive box: 17
- VSP E990: 9
- VSP E1090 with DBS2: 73
- VSP E1090 with DBN: 9
- VSP E1090 without expansion drive box: 65
The DB temperature data displayed in DkuTempAveInfo.csv (average temperature only), DkuTempMaxInfo.csv (maximum temperature only), and DkuTempMinInfo.csv (minimum temperature only) is the same value as the DB temperature data for DkuTempInfo.csv.
If the system is in maintenance mode or the SVP is rebooted, the data that is output every two hours might not contain data for the period. If a failure occurs in the storage system, the correct information might not be output.
Item | Description |
Date | Year, month, and date when temperature data was acquired in the format: YYYY/MM/DD hh:mm:ss |
DB00 DBPS001 Temperature minimum value | Minimum temperature (°C) for the two-hour period of DB00 DBPS001 |
DB47 DBPS472 Temperature minimum value | Minimum temperature (°C) for the two-hour period of DB47 DBPS472
|
ELunInfo.csv
This CSV file contains information about external volumes. Information about one external volume is output to multiple records according to the number of prioritized paths between the local and the external storage systems.
For details about external volumes, see the Hitachi Universal Volume Manager User Guide.
Item | Content |
VDEV# | Virtual device number to which the external volume is mapped |
Characteristic1 | Identification number of the external volume If the character string contains a comma, the comma is converted to a tab. |
Characteristic2 | Extended information for identifying the external volume |
Device | Product name reported to the host by the external volume If the character string contains a comma, the comma is converted to a tab. |
Capacity(blocks) | Capacity of the external volume (in blocks) |
Cache Mode | Indicates whether the write data from the host to the external storage system is reflected synchronously or asynchronously
|
ECC Group | Number of parity group to which the external volume is mapped. If the number starts with "E" (for example, E1-1), the parity group contains external volumes. Range of values: E1-1 to E16384-4096 |
Current MPU | Number and name of a current MP unit controlling the parity group to which the external volume is mapped
|
Setting MPU | Number and name of an MP unit configured to control the external volume indicated by ECC Group
|
Vendor | Vendor name of the external storage system |
Product Name | Product name of the external storage system |
Serial Number# | Serial product number of the external storage system |
Path Mode | Mode which indicates how the paths between local and external storage systems operate
|
Port | Name of a local port from which the external path is connected to the external storage system |
WWN | Port identifier number of the external storage system This item is blank when the "Package Type" is iSCSI. |
LUN | LU number set for the external volume. |
Priority | Priority of the paths between the storage systems to be used for connection with the external volume. "1" indicates the path with the highest priority. |
Status | Status of the path between storage systems.
|
IO TOV | I/O timeout value for the external volume Range of values: 5 to 240 |
QDepth | The number of Read/Write commands that can be issued to the external volume at a time Range of values: 2 to 128 |
Resource Group ID (ECC Group) | Resource group ID for the parity group that is mapping external volumes (in decimal format) Range of values: 0 to 1023 |
Resource Group Name (ECC Group) |
Resource group name of the parity group that is mapping external volumes |
Load Balance Mode | I/O load balance distribution logic specified for external volume:
|
Path Mode on Profile | Path mode on profile information of the external storage system:
|
ALUA Settable | Indicates whether ALUA mode can be set as path mode on the external storage system
|
ALUA Permitted | Indicates whether ALUA is used as path mode on the local storage system:
|
Target Port Asymmetric Access State | Status of the port on the external storage system when the path mode is ALUA:
|
Package Type | Type of CHB to which a port of the local storage system connecting to the external storage system belongs:
|
IP Address | IP address for an iSCSI target of an external storage system
|
TCP Port Number | TCP port number (1 through 65535) for the iSCSI target of an external storage system This item is blank when the "Package Type" is other than iSCSI. |
iSCSI Target Name | iSCSI target name of an external storage system This item is blank when the "Package Type" is other than iSCSI. |
Virtual Port ID | Virtual port number of own storage system to which external storage system is connected. If Virtual Port Mode is Disabled, this column to be blanked. |
EnvMonInfo.csv
This CSV file contains information about the power and temperature of the storage system. Power and temperature measurements from the environment monitor are recorded every 2 hours.
No records are created if the storage system is turned off. If the system is in maintenance mode or the SVP is rebooted, up to 2 hours of records could be lost.
If a failure occurs in the storage system, the correct information might not be output.
A hyphen(-) is displayed if the power and temperature information cannot be acquired due to a unit or network failure.
Item | Description |
Date | Year, month, and date when record data was acquired for the 2-hour period in the format: YYYY/MM/DD HH:MM:SS |
Electric power average | Average value of electric power (W) |
Electric power maximum value | Maximum value of electric power (W) |
Electric power minimum value | Minimum value of electric power (W) In the following cases, a lower value might be temporarily displayed:
|
DKC0 CLT01 Temperature average | DKC0: Average temperature of CLT01 (°C) |
DKC0 CLT01 Temperature maximum value | DKC0: Maximum temperature of CLT011 (°C) |
DKC0 CLT01 Temperature minimum value | DKC0: Minimum temperature of CLT01 (°C) |
DKC5 CLT52 Temperature average | DKC5 CLT52: Average temperature of CL2 (°C) |
DKC5 CLT52 Temperature maximum value | DKC5 CLT52: Maximum temperature of CL2 (°C) |
DKC5 CLT52 Temperature minimum value | DKC5 CLT52: Minimum temperature of CL2 (°C) |
FcSpNameInfo.csv
This CSV file contains information about Fibre Channel Security Protocols (FCSPs). A record is created for each initiator (host).
For details of port setting, see the Provisioning Guide.
Item |
Content |
Port |
Port name |
Host Group |
Host group name |
Target Username |
WWN information about the storage system required for authentication (16-digit hexadecimal number) |
Authentication of Group |
Information about whether to perform authentication or not
|
Initiator Username |
WWN information about the host required for authentication (16-digit hexadecimal number) |
Protocol |
Protocol used for authentication ("CHAP" or blank) |
FcSpPortInfo.csv
This CSV file contains information about ports related to Fibre Channel Security Protocols (FCSPs). A record is created for each port.
For details of port setting, see the Provisioning Guide.
Item |
Content |
Port |
Port name |
Time out(Sec) |
Time interval (in seconds) before retrying authentication in case of failure in authentication |
Refusal Intvl.(Min) |
Time interval (in minutes) before starting next authentication in case of failure in authentication for the number of times displayed by "Refusal Freq(Counts)" |
Refusal Freq.(Counts) |
Number of times of authentication allowable for connection to a port |
Switch Port Username |
WWN information about the Fabric switch required for authentication (16-digit hexadecimal number) |
Mode |
Mode of authentication between ports and FC switches
|
Authentication of Fabric Switch |
Information about whether to perform authentication of the FC switch identified by "Switch Port Username"
|
HduInfo.csv
Example:
DB Location,DB Status,Slot Size,DB Type DB00,Installed,2.5,DBN DB50&51,Installed,2.5,DBS2 DB50&51,Installed,2.5,DBS2 DB52&53,Installed,2.5,DBS2 DB52&53,Installed,2.5,DBS2 DB54,Installed,3.5,DB60 DB55,Installed,3.5,DB60 DB56,Installed,3.5,DB60 DB57,Installed,3.5,DB60 DB58,Installed,3.5,DB60 DB59,Installed,3.5,DB60 DB60,Installed,3.5,DB60 DB61,Installed,3.5,DB60
Item | Description |
DB Location | DB location name |
DB Status | Information about whether this DB is installed
|
Slot Size | Slot size (inches)
|
DB Type | DB type
|
IscsiHostInfo.csv
This CSV file contains information about iSCSI Initiator (Host) set to the channel board port. A record is created for each iSCSI Host (Initiator) target.
Item |
Content |
Port |
Port name |
iSCSI Name |
iSCSI host name |
Host Name |
Nickname for iSCSI host name |
iSCSI Target ID1 |
iSCSI target number (hexadecimal format, 00 to fe) |
Notes:
|
IscsiPortInfo.csv
This CSV file contains information about iSCSI information set to the channel board port. A record is created for each iSCSI host (initiator) target.
Item |
Content |
Port |
Port name |
IPv4 | IP Address |
IPv4 address Output example: xxx.xxx.xxx.xxx (decimal) |
IPv4 | Subnet Mask |
IPv4 subnet mask (decimal) Output example: xxx.xxx.xxx.xxx (decimal) |
IPv4 | Default Gateway |
Port IPv4 default gateway Output example: xxx.xxx.xxx.xxx (decimal) |
IPv6 | Mode |
Port IPv6 settings
|
IPv6 | Link Local Address |
Port IPv6 link local address
Auto is displayed if the link local address is automatically set. Blank if "IPv6 | Mode" is Disabled. |
IPv6 | Global Address |
IPv6 global address of the port
Auto is displayed if the global address is automatically set. Blank if "IPv6 | Mode" is Disabled. |
IPv6 | Assigned Default Gateway |
Port IPv6 assigned default gateway
Blank if "IPv6 | Mode" is Disabled. |
Channel Speed |
Data transfer speed of the port (for example, 1G, 10G, Auto) |
Security Switch |
Port security switch settings
|
TCP Port Number |
The number of the port for using socket (1 to 65535) |
Ethernet MTU Size (Byte) | MTU |
MTU settings
|
Keep Alive Timer (sec.) |
Keep alive timer value of iSCSI (30 to 64800) (sec) |
Selective ACK |
Selective ACK mode
|
Delayed ACK |
Delayed ACK mode
|
Maximum Window Size (KB) |
Window scale option settings
|
iSNS Server | Mode |
iSNS mode settings
|
iSNS Server | IP Address |
IP address of the iSNS server
|
iSNS Server | TCP Port Number |
Port number of TCP used for iSNS (1 to 65535). Blank if "iSNS Server | Mode" is Off. |
VLAN | Tagging Mode |
VLAN tagging mode set to the port
|
VLAN | ID |
VLAN number set to the port (1 to 4094) Blank if "VLAN | Tagging Mode" is set to Off. |
Resource Group ID (Port) |
Resource group ID of the port (0 to 1023 in decimal) |
Resource Group Name(Port) |
Resource group name of the port |
iSCSI Name |
iSCSI name of the port |
CHAP User Name |
Authenticated user name of the port |
IPv6 | Global Address 2 |
IPv6 global address 2 of the port
Auto is displayed if the global address 2 is automatically set. Blank if "IPv6 | Mode" is Disabled. |
Virtual Port Mode |
Virtual port mode of the port
|
IscsiTargetInfo.csv
This CSV file contains information about iSCSI target information set to the channel board port. A record is created for each iSCSI target.
Item |
Content |
Port |
Port name |
iSCSI Target Alias |
iSCSI target alias |
iSCSI Target ID |
Number of the iSCSI target (00 to fe, hexadecimal) |
iSCSI Target Name |
Name of the iSCSI target |
Host Mode |
Host mode set to the iSCSI target (hexadecimal) |
Host Mode Option |
Host mode option set to the iSCSI target (decimal) Separated with a semicolon (;) if multiple host mode options are set. |
Security Switch |
Security switch status set to the iSCSI target port
|
Authentication | Method |
Authentication method settings of the iSCSI target
|
Authentication | Mutual CHAP |
Mutual CHAP authentication function settings of the iSCSI target
|
Authentication | User Name |
User name set when iSCSI target was authenticated |
Resource Group ID (iSCSI Target) |
Resource group ID of the iSCSI target (0 to 1023) |
Resource Group Name (iSCSI Target) |
Resource group name of the iSCSI target |
JnlInfo.csv
This CSV file contains information about journals. A record is created for each journal.
Item | Content |
JNL# | Journal number (in hexadecimal) |
Current MPU | Number and name of MP unit currently controlling the journal (MPU-10, MPU-20) |
Setting MPU | Number and name of MP unit configured to control the journal (MPU-10, MPU-20) |
LdevCapaInfo.csv
This CSV file contains information about LDEV capacities. A record is created for each of the classifications shown in "Volume Kind".
Item |
Content |
Volume Kind |
The following classifications are output:
|
Allocated LDEV Capacity (GB) |
Allocated LDEV capacity |
Unallocated LDEV Capacity (GB) |
Unallocated LDEV capacity |
Reserved Capacity (GB) |
Reserved LDEV capacity |
Total Volume Capacity (GB) |
Total capacity of "Allocated LDEV Capacity", "Unallocated LDEV Capacity" and "Reserved Capacity" |
Free Space (GB) |
Free Space |
Total Capacity (GB) |
Total Capacity The sum of "Total Volume Capacity" and "Free Space" |
LdevCountInfo.csv
This CSV file contains information about the number of logical devices (LDEVs). A record is created for each of the classifications shown in "Volume Kind".
Item | Content |
Volume Kind |
The following classifications are output:
|
Allocated OPEN LDEVs |
Number of allocated open-system volumes (LDEVs) |
Unallocated OPEN LDEVs |
Number of unallocated open-system volumes (LDEVs) |
Reserved OPEN LDEVs |
Number of reserved open-system volumes (LDEVs) |
V-VOL |
Number of virtual volumes This item is output only when "Volume Kind" is Total Volumes. This item is blank when "Volume Kind" is Internal Volumes or External Volumes. |
Total(All LDEVs) |
Total number of LDEVs |
ECC Groups |
Total number of parity groups |
LdevInfo.csv
This CSV file contains information about logical devices (LDEVs). A record is created for each LDEV.
Item |
Content |
ECC Group |
Number of parity group where the LDEV belongs. Output example: X-Y (decimals)
|
LDEV# |
LDEV number (00:00:00 to 00:fe:ff) |
LDEV Name |
LDEV name If the character string contains a comma, the comma is converted to a tab. |
LDEV Emulation |
LDEV emulation type |
LDEV Type |
LDEV type:
|
LDEV Attribute |
LDEV Attribute:
|
Volume Size(Cyl) |
LDEV capacity (in cylinders) Note: This item is not applicable (the output value is not valid). |
Volume Size(MB) |
LDEV capacity (in MB) |
Volume Size(Blocks) |
LDEV capacity (in blocks) |
CVS |
Information about whether the LDEV is a custom-sized volume:
|
Pool ID |
Pool number. This item is blank except in the following cases:
|
RAID Concatenation#0 |
Number of parity group to be concatenated to parity group (#0) identified by ECC Group. Blank if the parity group is not concatenated to another parity group. |
RAID Concatenation#1 |
Number of parity group to be concatenated to parity group (#1) identified by ECC Group. Blank if the parity group is not concatenated to another parity group. |
RAID Concatenation#2 |
Number of parity group to be concatenated to parity group (#2) identified by ECC Group. Blank if the parity group is not concatenated to another parity group. |
ORACLE CHECK SUM |
Information about whether this LDEV is an Oracle checksum target.
|
Current MPU |
Number of the MP unit currently controlling the LDEV. (MPU-10, MPU-20) |
Setting MPU |
Number of the MP unit configured to control LDEV. (MPU-10, MPU-20) |
Allocated |
Information about whether the host can access the LDEV.
|
Pool Name |
Name of the pool:
|
CmdDevSecurity |
Indicates whether Security is specified as the attribute for the command device.
|
CmdDevUserAuth |
Indicates whether User Authentication is specified as the attribute for the command device.
|
CmdDevDevGrpDef |
Indicates whether Device Group Definition is specified as the attribute for the command device.
|
Resource Group ID (LDEV) |
LDEV resource group ID (number in the decimal format) |
Resource Group Name (LDEV) |
LDEV resource group name (0 to 1,023, decimal) |
Encryption |
Indicates whether the parity group identified by ECC Group is encrypted.
|
T10 PI |
T10 PI attribute set for the LDEV:
|
ALUA Mode |
Indicates whether the ALUA mode is enabled.
|
Accelerated Compression |
Indicates whether accelerated compression is enabled. For internal volumes:
If the parity group with LDEV does not support accelerated compression, a blank space is displayed. Also, for external volumes, a blank is displayed. |
Namespace ID | Namespace ID of the LDEV This item is displayed only for VSP E1090. This item is blank if the LDEV is not set as a namespace. |
LdevStatus.csv
This CSV file contains information about the status of logical devices (LDEVs). A record is created for each LDEV.
Item |
Content |
VDEV# |
Virtual device number in which the LDEV is defined |
VDEV Status |
VDEV status of "VDEV#"
|
HDEV# |
LDEV number |
HDEV Status |
LDEV status
|
LDEV Emulation |
LDEV emulation type |
ECC Group |
Number of the parity group where the LDEV belongs.
|
LPartition.csv
This CSV file contains information about the cache logical partitioning function. A record is created for each cache partition for a managed resource.
For details about the cache logical partitioning function, see the Performance Guide.
Item | Content |
CLPR# | CLPR ID (in decimal) |
CLPR Name | CLPR name |
Cache Size(MB) | Cache size allocated to this CLPR (in MB) |
ECC Group | Number of parity group allocated to this CLPR
|
LDEV#(V-VOL) | LDEV number allocated to this CLPR:
The type of this LDEV is Dynamic Provisioning, Thin Image, or ALU. This item is blank if no LDEV is assigned to the CLPR ID. |
LunInfo.csv
This CSV file contains information about LU path definitions. A record is created for each set of LU path definitions that belongs to a host group. When only the port name (Port) is output, it indicates that no LU path is defined for the port (which is used only for a remote path or an external path). For more information about LU path definitions, see the Provisioning Guide.
Item |
Description |
Port |
Port name |
Host Group |
Host group name If "Package Type" is iSCSI, the iSCSI target alias is output. |
Host Mode |
Host mode specified for this host group (hexadecimal) |
Host Mode Option |
Host mode option set for this host group (decimal) If more than one option is specified, the options are separated by semicolons (;). This item is blank when no host mode option has been specified. |
LUN# |
LUN number for this LU path definition (hexadecimal) This item is blank when no LU path is defined for the host group. |
LDEV# |
LDEV number for this LU path definition This item is blank when no LU path is defined for the host group. |
Command Device |
Information about whether the LDEV is a command device:
|
Command Security |
Information about whether the command device is secured:
|
CVS |
Information about whether the LDEV is a custom-sized volume:
|
CHB Location |
Name of the CHB on which this port is installed Output example: CHB-1D |
Package Type |
CHB type for CHB Location Output example for Fibre: 32FC4R (CHB) Output example for iSCSI: 10iSCSI2c (CHB) |
Resource Group ID (Host Group) |
Resource group ID of a host group (0 to 1,023, decimal) |
Resource Group Name (Host Group) |
Resource group name of a host group |
T10 PI Mode |
Indicates whether the T10 PI mode can be applied to the port for which the LU path is defined:
|
T10 PI |
Information about the T10 PI attribute which is set for the LDEV number of the LU path definition.
|
Asymmetric Access State | Asymmetric access status Indicates the asymmetric access status:
|
LunPortInfo.csv
This CSV file contains information about LU path definition. A record is created for each port.
For details of LU path definition, see the Provisioning Guide.
Item |
Content |
Port |
Port name |
Security Switch |
The setting status of the security switch:
|
Port Address |
Port address (2-digit hexadecimal number) 00 to ff This item is blank when "Package Type" is iSCSI. |
Loop ID |
Port address (0 - 125, decimal) This item is blank when "Package Type" is iSCSI. |
Fabric |
Setting status of the Fabric switch:
|
Connection |
Fibre topology setting:
|
Channel Speed |
Channel speed of this port (for example, 4G, 10G, 32G) |
WWN |
WWN of this port (hexadecimal number) This item is blank when "Package Type" is iSCSI. |
CHB Location |
CHB on which the port is installed. |
Package Type |
CHB type for CHB Location Output example for Fibre: 32FC4R (CHB) Output example for iSCSI: 10iSCSI2c (CHB) |
T10 PI Mode |
Indicates whether the T10 PI mode can be applied to the port:
|
MicroVersion.csv
This CSV file contains information about software versions.
Item | Content |
DKCMAIN | The version of the firmware for the RAID storage system (10 digits) |
ROM BOOT | ROM BOOT firmware version (6 digits) |
RAM BOOT | RAM BOOT firmware version (6 digits) |
Config | Config version (8 digits) |
HDD | HDD firmware version (4 digits) Displayed in HDD device type cord: version format. A colon is displayed when no HDDs are installed. |
CFM | CFM firmware version (8 digits) |
Printout Tool | Printout tool version (xx-yy-zz-mm/aa) |
CHB(FC32G) | 32G FC protocol chip firmware version (8 digits) |
CHB(iSCSI) | CHB9(iSCSI) protocol chip firmware version (8 digits) |
GUM | GUM firmware version (8 digits) |
CTL_NSW | CTL_NSW firmware version (6 digits) |
CTL_eDKBN | CTL_eDKBN firmware version (6 digits) |
Expander1 | Expander firmware version (6 digits) |
DKB1 | DKBN firmware version (6 digits) |
DKBN2 | DKBN firmware version (6 digits) (not supported on VSP E590, VSP E790) |
NSW2 | NSW firmware version (6 digits) (not supported on VSP E590, VSP E790) |
Unified Hypervisor | Displayed only for VSP G/F700 and VSP G/F900. |
NASFWINST | Displayed only for VSP G/F700 and VSP G/F900. |
NASFW | Displayed only for VSP G/F700 and VSP G/F900. |
Notes:
|
Item | Content |
DKCMAIN | The version of the firmware for the RAID storage system (10 digits) |
ROM BOOT | ROM BOOT firmware version (6 digits) |
RAM BOOT | RAM BOOT firmware version (6 digits) |
Config | Config version (8 digits) |
HDD | HDD firmware version (4 digits) A colon is displayed for VSP E990. |
CFM | CFM firmware version (8 digits) |
Printout Tool | Printout tool version (xx-yy-zz-mm/aa) |
CHB(FC32G) | 32G FC protocol chip firmware version (8 digits) |
CHB(iSCSI) | CHB9(iSCSI) protocol chip firmware version (8 digits) |
GUM | GUM firmware version (8 digits) |
DKBN | DKBN firmware version (6 digits) |
NSW | NSW firmware version (6 digits) |
EDKBN | EDKBN firmware version (6 digits) |
Item | Content |
DKCMAIN | The version of the firmware for the RAID storage system (10 digits) |
ROM BOOT | ROM BOOT firmware version (6 digits) |
RAM BOOT | RAM BOOT firmware version (6 digits) |
Config | Config version (8 digits) |
HDD | HDD firmware version (4 digits) Displayed in HDD device type cord: version format. A colon is displayed when no HDDs are installed. |
CFM | CFM firmware version (8 digits) |
Printout Tool | Printout tool version (xx-yy-zz-mm/aa) |
CHB(FC32G) | 32G FC protocol chip firmware version (8 digits) |
CHB(iSCSI) | CHB9(iSCSI) protocol chip firmware version (8 digits) |
GUM | GUM firmware version (8 digits) |
DKB | DKB firmware version (6 digits) |
DKBN | DKBN firmware version (6 digits) |
NSW | NSW firmware version (6 digits) |
EDKBN | EDKBN firmware version (6 digits) |
Expander | Expander firmware version (6 digits) |
MlcEnduranceInfo.csv
This CSV file contains information about endurance information of MLC. A record is created for each MLC endurance information.
If you change the SVP time 1 month or more, the history acquisition months will not be in order.
Item |
Content |
ECC Group |
Number of parity groups of which this MLC (including FMD and FMD DC2 ) is a component.
|
CR# |
C# and R# (2-digit hexadecimal numbers), which identify the PDEV Output in the format of "XX/YY" XX: C# YY: R# |
Device Type-Code |
Drive type code of this drive Output example: SLR5A-M800SS |
Used Endurance Indicator (%) |
The current used endurance of SSD life (0 to 100) The value of this indicator increases due to drive operation associated with internal processing of the storage system, and the host I/O. Even when no data is copied due to a drive failure, the value of this indicator increases because the spare drive also performs internal processing. |
History1 (date) |
Date on which the used endurance of SSD life was acquired (1 month ago) Output example: yyyy/mm/dd |
History1 (%) |
The used endurance of SSD life (0 to 100)(1 month ago) |
History2 (date) |
Date on which the used endurance of SSD life was acquired (2 months ago) Output example: yyyy/mm/dd |
History2 (%) |
The used endurance of SSD life (0 to 100) (2 months ago) |
History3 (%) ... History 119 (%) |
Life (0 to 100) (3 months ago ...119 months ago) |
History120 (date) |
Date on which the used endurance of SSD life was acquired (120 months ago) Output example: yyyy/mm/dd |
History120 (%) |
The used endurance of SSD life (0 to 100) (120 months ago) |
ModePerLpr.csv
This CSV file contains information about system option modes. A record is created for each system option mode.
Item |
Content |
System Option Mode# |
System option mode # (0 to 2047, decimal number) |
LPR#0, LPR#1, …, LPR#31 |
System option mode for LPR#0 to LPR#31
|
MpPathStatus.csv
This CSV file contains information about the status of logical paths. A record is created for each MP blade or LR.
Item | Content |
MPU#/CTL# | MP unit number or CTL number (2-digit hexadecimal number)
|
CMG#00-00 to 01 CMG#01-00 to 01 | Path status* for the MP unit number with the cache module (CMG#XX-YY) XX: I path, YY: CMG# |
MPU#00-00 to 01 MPU#01-00 to 01 | Path status* and the MP unit for the MP unit number (MPU#XX-YY) XX: I path, YY: MPU# |
CMG#00-00 to 01 CMG#01-00 to 01 | Path status* with the cache module for the CTL number (CMG#XX-YY) XX: I path, YY: CMG# |
MPU#00-00 to 01 MPU#01-00 to 01 | Path status* with the MP unit number for the CTL number (MPU#XX-YY) XX: I path, YY: MPU# |
* Path status: 1=Normal, 0=Abnormal |
MpPcbStatus.csv
This CSV file contains information about the status of MP Unit. A record is created for each MP unit.
Item | Content |
MPU ID | MP unit ID (MPU-10, MPU-20) |
Auto Assignment | Information about whether this MP unit is set to be automatically assigned to each resource.
|
MPU Status | MP unit status:
|
MP#00, #01, …, #13 | MP status
The number of output items depends on the number of installed MPs:
|
PcbRevInfo.csv
This CSV file contains information about revisions of packages such as channel boards (CHBs) and others. A record is created for each package.
Item |
Content |
Cluster# |
Cluster number 1 or 2 |
Location |
Part name |
FRU number |
Product name of the package or some other name |
PK Revision |
Revision of the package |
Factory |
Factory manufacturing the package |
Number |
Serial number of the package |
MAC Address |
MAC address of the package This item always remains blank. |
PdevCapaInfo.csv
This CSV file contains information about physical device (PDEV) capacities. A record is created for each of the classifications shown in "PDEV Kind".
Item |
Content |
PDEV Kind |
The following four classifications are output:
|
HDD Drive |
HDD drive capacity (TB) |
Spare Drive |
Spare drive capacity (TB) |
SSD Drive |
SSD capacity (TB) |
Free Drive |
Free drive capacity (TB) |
PdevInfo.csv
This CSV file contains information about physical devices (PDEVs). A record is created for each PDEV.
Item | Content |
ECC Group | Number of parity group of which this PDEV is a component:
|
Emulation Type | Emulation type for the parity group indicated by "ECC Group" This item is blank when the ECC Group is Spare Drive. |
CR# | C# and R# (2-digit hexadecimal numbers that identify the PDEV) Output in the format XX/YY, where:
|
PDEV Location | PDEV location name |
Device Type | Drive type (for example, SAS, SSD) |
RPM | Revolutions per minute (unit: rpm) This item is blank when the drive type is not HDD. |
Interface | Drive control interface (for example, NVMe, SAS) |
Device Type-Code | Device type code of this drive (for example, DKR5D-J600SS) |
Device Size | Drive size (inches) (for example, 2.5, 3.5) This item is blank when the drive type is FMD. |
Device Capacity | Drive capacity (GB or TB) |
Drive Version | Drive firmware version |
DKB1 | Name of the DKB1 controlling the PDEV |
DKB2 | Name of the DKB2 controlling the PDEV |
DKB3 | Name of the DKB3 controlling the PDEV This item is output only for VSP E990 and VSP E1090. |
DKB4 | Name of the DKB4 controlling the PDEV This item is output only for VSP E990 and VSP E1090. |
Serial Number # | Serial number of this drive |
RAID Level | RAID level of the parity group indicated by "ECC Group" This item is blank when the "ECC Group" is Spare Drive or Free Drive |
RAID Concatenation #0 | Number of parity group to be concatenated to parity group (#0) identified by "ECC Group" This item is blank when the parity group is not concatenated to another parity group or is Spare Drive. |
RAID Concatenation #1 | Number of parity group to be concatenated to parity group (#1) identified by "ECC Group" This item is blank when the parity group is not concatenated to another parity group or is Spare Drive. |
RAID Concatenation #2 | Number of parity group to be concatenated to parity group (#2) identified by "ECC Group" This item is blank when the parity group is not concatenated to another parity group or is Spare Drive. |
Resource Group ID (ECC Group) | Resource group ID of parity group (decimal number) |
Resource Group Name (ECC Group) |
Resource group name of parity group |
Encryption | Encryption status of the parity group to which the PDEV belongs:
|
Accelerated Compression |
Displayed only for VSP G130, G/F350, G/F370, G/F700, G/F900. |
Automatically manage compressed space of FMD parity group | Indicates whether to manage the compressed area of the FMD parity group automatically.
This item is blank when the parity group to which the PDEV belongs does not support accelerated compression. |
PdevStatus.csv
This CSV file contains information about the status of physical devices (PDEVs). A record is created for each PDEV.
Item |
Content |
CR# |
C# and R# (2-digit hexadecimal numbers), which identify the PDEV Output in the format XX/YY, where:
|
Pdev Status |
PDEV status1 |
Port0 Status |
Status of Port 0 on this PDEV1 |
Port1 Status |
Status of Port 1 on this PDEV1 |
Pdev Location |
Location name of this PDEV |
Notes:
|
PECBInfo.csv
This CSV file contains information about the PECB (PCIe channel board) and connecting destination.
For VSP E590 and VSP E790, a hyphen (-) is output for all items.
Item | Content |
Location | PECB location name |
Status | Whether the PECB is installed
|
Type | Destination module type of the PECB
|
Expansion mode | Expansion mode set in the destination module of the PECB |
PkInfo.csv
This CSV file contains information about channel boards (CHBs). A record is created for each CHB.
Item |
Content |
CHB Location |
CHB name |
Port# |
Number of the port installed on the CHB (2-digit hexadecimal number), 00 to ff |
Port |
Name of port installed on the CHB |
Package Type |
CHB type indicated on the CHB Location Output examples for FC: 16FC2 (CHB), 32FC4R (CHB) Output examples for iSCSI: 10iSCSI2o (CHB), 10iSCSI2c (CHB) |
SFP Kind |
Type of SFP (Small Form factor Pluggable):
|
SFP Status |
SFP Status:
|
Fabric |
Fibre topology settings indicating the setting status of the Fabric switch:
|
Connection |
Fibre topology settings:
|
Port Address |
Port address (00 to ff, 2-digit hexadecimal number) This item is blank when the CHB type is iSCSI. |
Resource Group ID (Port) |
Resource group ID of port (0 to 1023, decimal number) |
Resource Group Name (Port) |
Resource group name of the port |
Port Internal WWN |
Port WWN This item is blank when the CHB type is iSCSI. |
T10 PI Mode |
Indicates whether the T10 PI mode can be applied to the port:
|
SFP Data Transfer Rate |
Maximum transfer rate of SFP which the mounted package supports, for example, 10G, 32G. This item is blank when the CHB type is iSCSI. |
Mode | Operation mode of the Fibre Channel port
This item is displayed only for VSP E1090. |
PpInfo.csv
This CSV file contains information about the software. A record is created for each software product.
For details about the license key, see Managing license keys.
Item |
Content |
Program Product Name |
Software name |
Install |
Information about whether the installed license key is enabled:
|
Key Type |
Installed license key type:
|
Permitted Volumes(TB) |
Permitted volume capacity for this software (in TB). (The used volume capacity is not output.) If no upper limit value is set for the capacity, "Unlimited" is output. This item is blank in either of the following cases:
|
Expiration Date |
Expiration date of the software The format is mm/dd/yyyy (month/day/year). This item is blank in either of the following cases:
|
Status |
License key status of the software:
|
SMfundat.csv
This CSV file contains information about SM functions. A record is created for each of the classifications shown in "SM Install Function".
Item | Content |
SM Install function | The following classifications are output:
|
Availability | Information about whether the function of "SM Install function" is enabled
|
SsdDriveInfo.csv
This CSV file contains information about SSDs. A record is created for each drive.
Item | Content |
ECC Group | Number of the parity group to which this SSD belongs
|
CR# | C# and R# (2-digit hexadecimal numbers that identify the PDEV) Output in the format XX/YY, where:
|
PDEV Location |
Drive type code of the PDEV location name for this drive |
Device Type-Code | Drive type code Output example: SLR5A-M800SS |
Device Capacity | Drive capacity in GB or TB |
SSD Device Type | SSD drive type (for example, SSD(RI), MLC, FMD) |
Used Endurance Indicator (%) | Used endurance of SSD life (0 to 100) |
Used Endurance Indicator Threshold (%) | Drive life threshold (0 to 100) |
Used Endurance Indicator Warning SIM (%) | Warning SIM threshold (0 to 100) |
FMD Battery Life Indicator Warning SIM (%) | Displayed only for VSP G130, G/F350, G/F370, G/F700, G/F900. Threshold of battery life warning SIM (0 to 100) This item is blank if the SSD is other than FMD. |
FMD Battery Life Indicator (%) | Displayed only for VSP G130, G/F350, G/F370, G/F700, G/F900. Used battery life (0 to 100) This item is blank if the SSD is other than FMD. |
SsidInfo.csv
This CSV file contains information about SSIDs. A record is created for each SSID.
Item |
Content |
DEV# Start |
First LDEV number for the SSID |
DEV# End |
Last LDEV number for the SSID |
SSID |
Subsystem ID (hexadecimal) |
SysoptInfo.csv
This CSV file contains information about system options.
Item |
Content |
Spare Disk Recover |
Speed of copying data to the spare drive.
|
Dynamic Sparing |
Information about whether to perform automatic copy to a spare drive if the occurrences of drive failures exceed the threshold.
|
Correction Copy |
Information about whether to perform correction copy to a spare drive if a drive is blocked.
|
Disk Copy pace |
Speed of copying the spare drive in the Interleave mode.
|
System Option On |
System options that are set to ON. Output example: modeXXXX (0 to 2047, decimal number) |
Link Failure Threshold |
Threshold to notify the link failure (0 to 255, decimal) |
WwnInfo.csv
This CSV file contains information about hosts. A record is created for each host.
Item |
Content |
Port |
Port name. |
Host Group |
Host group name iSCSI target alias is output if the "Package Type" is iSCSI. |
Host Mode |
Host mode that is set for the host group (hexadecimal) |
Host Mode Option |
Host mode option that is set for the host group (decimal) Multiple options are separated by semicolons (;). This item is blank when no host mode options have been specified. |
WWN |
World Wide Name of the host bus adapter registered to the host group (hexadecimal number) This item is blank when no valid WWN has been specified. |
Nickname |
Nickname of the host This item is blank when no nickname has been specified. |
Host Group# |
Host group number (00 to fe, hexadecimal number) The iSCSI target ID is output when the "Package Type" is iSCSI. |
CHB Location |
Name of port installed on the CHB |
Package Type |
CHB type indicated on the CHB Location Output example for FC: 16FC2 (CHB), 32FC4R(CHB) Output example for iSCSI: 10iSCSI2o (CHB), 10iSCSI2c (CHB) |
T10 PI Mode |
Indicates whether the T10 PI mode can be applied to the port:
|