Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

Report examples: table view

Some Device Manager - Storage Navigator reports appear in table format.

The following figure provides examples of reports in table format. The GUID-6E7A0CA5-8D25-488F-AAF7-55B9446F25B8-low.gif icons are displayed before the names of the reports in table view. If the icons are not displayed correctly, update the window. To sort data in table reports, click any column header.

GUID-B400368F-E6B9-4F4D-BFE0-E7008405EE74-low.png

CHAP Users report

Item Description
Port Location Name of the port
User Name Name of the CHAP user for authentication
iSCSI Target Alias Alias of the iSCSI target
iSCSI Target Name Name of the iSCSI target

Disk Boards report

Item

Description

DKB

Location of the disk board.

  • "External" is displayed when the storage system has an external storage system.
  • "External (FICON DM)" is displayed when the storage system has volumes for FICON DM.

Number of PGs

The number of the parity groups that the disk board controls.

  • If "DKB" is "External", this item indicates the number of parity groups mapped to external volumes.
  • If "DKB" is "External (FICON DM)", this item indicates the number of parity groups mapped to volumes for FICON DM.

Number of LDEVs (Total)

The number of the logical volumes belonging to the parity groups that the disk board controls.

Number of LDEVs (Unallocated)

The number of the logical volumes that are inaccessible from the host and belong to the parity groups controlled by the disk board.

Total LDEV Capacity (MB)

Total capacity of the logical volumes belonging to the parity groups that the disk board controls.

Unallocated LDEV Capacity (MB)

Total capacity of the logical volumes that are inaccessible from the host and belong to the parity groups controlled by the disk board.

Host Groups / iSCSI Targets report

Item

Description

Port Location Name of the port
Type Type of the host group
Host Group Name / iSCSI Target Alias Name of the host group / alias of the iSCSI target
Host Group ID / iSCSI Target ID Number of the host group / ID of the iSCSI target
iSCSI Target Name Name of the iSCSI target
Resource Group Name Resource Group Name where the host group belongs
Resource Group ID Resource Group ID where the host group belongs
Number of LUNs The number of LU paths defined to the host group
Number of LDEVs The number of logical volumes that are accessible from the hosts in the host group
Number of PGs The number of parity groups with logical volumes that are accessible from the hosts in the host group
Number of DKBs The number of disk boards controlling the parity groups where the logical volumes that are accessible from the hosts in the host group belong
Total LDEV Capacity (MB) Total capacity of the logical volumes accessible from the hosts in the host group. This is the total capacity of LDEVs referred to in "Number of LDEVs".
Port Security Security of the port
Authentication : Method

iSCSI target method authentication settings

  • CHAP
  • None
  • Comply with Host Setting
Authentication : Mutual CHAP

Enable or disable the iSCSI target mutual CHAP

  • Enabled
  • Disabled
Authentication : User Name Authenticated iSCSI target user name
Authentication : Number of Users The number of authenticated users registered in the iSCSI target
Host Mode Host mode of the host group
Host Mode Option Host mode option of the host group. Host mode options are separated by semicolons (;) when more than one option is specified.
Number of Hosts The number of the hosts in the host group.

Hosts report

Item

Description

Port Location Name of the port
Type Port type
Port Internal WWN Port WWN
Port Security Port security setting
Host Group Name / iSCSI Target Alias Name of the host group / alias of the iSCSI target
iSCSI Target Name Name of the iSCSI target
Host Mode Host mode of the host group
Host Mode Option Host group host mode option. When more than one host mode option is specified, they are separated by semicolons (;)
Host Name Name of the host that can access the LU path through the port
HBA WWN / iSCSI Name Host WWN (16-digit hexadecimal) or host iSCSI name

Logical Devices report

Item Description
LDEV ID The logical volume number
LDEV Name The logical volume name
Capacity (MB) Capacity of the logical volume
Emulation Type Emulation type of the logical volume
Resource Group Name Name of the resource group to which the LDEV belongs
Resource Group ID ID of the resource group to which the LDEV belongs
PG Number of the parity group to which the LDEV belongs.
  • If the number starts with "E" (for example, E1-1), the parity group contains external volumes.
  • If the number starts with "M" (for example, M1-1), the parity group contains FICON DM volumes.

    A hyphen (-) is displayed for Dynamic Provisioning and Thin Image V-VOLs.

RAID Level RAID level of the parity group to which the LDEV belongs*
Drive Type/Interface Type and interface of the drives in the parity group to which the logical volume belongs

For VSP E1090, this item is displayed as "Drive Type/Interface/RPM".

Drive Type-Code Type code of the drives in the parity group to which the logical volume belongs*
Drive Capacity Capacity of the drives in the parity group to which the LDEV belongs*
PG Members Drive locations of the parity group to which the LDEV belongs*
Allocated

Information about whether the host can access the LDEV:

  • Y: The host can access the volume.
  • N: The host cannot access the volume.
SSID SSID of the LDEV
CVS Information about whether the LDEV is a custom-size volume
OCS Oracle checksum
Attribute Attribute of the LDEV
Provisioning Type Provisioning type of the LDEV
Pool Name
  • For V-VOLs of Dynamic Provisioning, the name of the pool related to the logical volume is displayed.
  • If the logical volume attribute is Pool, the name of the pool to which the logical volume belongs is displayed.
  • When neither of the above is displayed, the pool name is blank.
Pool ID ID of the pool indicated by "Pool Name".

A hyphen (-) is displayed for volumes other than pool-VOLs or V-VOLs.

Current MPU Number of the MP unit that currently controls the LDEV
Setting MPU Number of the MP unit that you specified to control the LDEV
Command Device: Security Indicates whether Security is specified as the attribute for the command device. A hyphen (-) is displayed when "Attribute" is not "CMDDEV".
Command Device:

User Authentication

Indicates whether User Authentication is specified as the attribute for the command device. A hyphen (-) is displayed when "Attribute" is not "CMDDEV".
Command Device:

Device Group Definition

Indicates whether Device Group Definition is specified as the attribute for the command device. A hyphen (-) is displayed when "Attribute" is not "CMDDEV".
Encryption Indicates whether the parity group to which the LDEV belongs is encrypted:
  • For internal volumes: Enabled (encrypted) or Disabled (not encrypted)
  • For external volumes: blank
ALUA Mode Indicates whether the ALUA mode is enabled:
  • Enabled: ALUA mode is enabled.
  • Disabled: ALUA mode is disabled.
T10 PI Indicates the T10 PI attribute set for the LDEV:
  • Enabled
  • Disabled
  • Blank if the emulation type is not OPEN-V
RPMRevolutions-per-minute (RPM) (unit: krpm) of the drive in the parity group to which the LDEV belongs.

A hyphen (-) is displayed when the drive type is not HDD.*

This item is output only when the firmware version is 93-05-02 or later. For VSP E1090, this item is displayed between Interface and Drive Type-Code.

Namespace IDNamespace ID of the LDEV

This item is displayed only for VSP E1090.

This item is blank if the LDEV is not set as a namespace.

* A hyphen (-) is displayed if the LDEV is an external volume.

LUNs report

Item Description
Port Location Name of the port
Internal WWN / Internal iSCSI Name Port WWN (16-digit hexadecimal) or port iSCSI name
Port Security Name of the type of security of the port
Host Group Name / iSCSI Target Alias Name of the host group or alias of the iSCSI target
iSCSI Target Name Name of the iSCSI target
Host Mode Host mode of the host group
Host Mode Option Host mode option of the host group. Host mode options are separated by semicolons (;) when more than one option is specified.
LUN Logical unit number
LDEV ID Logical volume number
Emulation Type Emulation type of the logical volume
Capacity (MB) Capacity of the logical volume
Asymmetric Access State Asymmetric access status:
  • Active/Optimized: Prioritized
  • Active/Non-Optimized: Lower priority

MP Units report

Item

Description

MP Unit ID

MP unit ID

Auto Assignment

Auto assignment attribute for the MP unit

Number of Resources (LDEV)

Number of LDEVs that the MP unit controls

Number of Resources (Journal)

Number of journals that the MP unit controls

Number of Resources (External Volume)

Number of external volumes that the MP unit controls (includes volumes for FICON DM)

Number of Resources (Total)

The total number of resources that the MP unit controls. It is the total of Number of Resources (LDEV), Number of Resources (Journal), and Number of Resources (External Volume).

MP Unit Details report

Item

Description

MP Unit ID

MP unit ID

Auto Assignment

Auto assignment attribute for the MP unit

Resource ID

ID of this resource that the MP unit controls

Resource Name

The name of the resource that the MP unit controls. If "Type" is LDEV, the LDEV name that is set is displayed. A hyphen (-) displays for journal volumes or external volumes.

Type

The type of the resource that the MP unit controls

Parity Groups report

Item Description
PG Parity group number
  • If the number starts with "E" (for example, E1-1), the parity group contains external volumes (Hitachi Universal Volume Manager User Guide).
  • If the number starts with "M" (for example, M1-1), the parity group contains volumes for FICON DM.
DKB Name of the disk board that controls the parity group1
RAID Level RAID level of the parity group1
Resource Group Name Name of the resource group in which the parity group belongs
Resource Group ID ID for the resource group in which the parity group belongs
Emulation Type Emulation type of the parity group
Number of LDEVs (Total) The number of the logical volumes in the parity group
Number of LDEVs (Unallocated) The number of the logical volumes in the parity group that the host cannot access
Total LDEV Capacity (MB) Capacity of the logical volumes in the parity group
Unallocated LDEV Capacity (MB) Capacity of the logical volumes in the parity group that the host cannot access
Drive Type-Code Type code of the drive in the parity group
  • The type code of the first drive in the parity group.
  • If the parity group contains external volumes, the drive type code displays the vendor, the model, and the serial number of the storage system.
  • Separated by semicolons (;) if multiple drive types are set.
Drive Type/Interface (VSP E590, VSP E790, VSP E990) Drive type and interface of the drives in the parity group to which the LDEV belongs1

For VSP E1090 this item is displayed as "Drive Type/Interface/RPM".

Drive Type/Interface/RPM (VSP E1090) Drive type, drive control name, and revolutions-per-minute (RPM) (unit: krpm) of the drives in the parity group to which the LDEV belongs1

A hyphen (-) is displayed instead of the RPM when the drive type is not HDD.

Drive Capacity Capacity of the drive in the parity group1
RAID Concatenation #0 The number indicating a parity group #0 connected to this parity group1,2
RAID Concatenation #1 The number indicating a parity group #1 connected to this parity group1,2
RAID Concatenation #2 The number indicating a parity group #1,2 connected to this parity group1,2
Encryption Indicates whether the parity group is encrypted.
  • For internal volumes: Enabled (encrypted) or Disabled (not encrypted)
  • For external volumes: A hyphen (-) is displayed.
RPMRevolutions-per-minute (RPM) (unit: krpm) of the drives in the parity group.1

A hyphen (-) is displayed when the drive type is not HDD.

This item is output only when the firmware version is 93-05-02 or later.

Notes:

  1. A hyphen is displayed if the parity group contains external volumes.
  2. A hyphen is displayed if the parity group is not connected with another parity group or if the parity group contains external volumes including volumes for FICON DM.

PDEVs report

The following table describes the items in the PDEVs report.

Item Description
LocationPDEV name
CR#C# and R# (2-digit hexadecimal numbers that identify the PDEV Output in the format XX/YY, where:
  • XX: C#
  • YY: R#
PGPDEVs parity group
Emulation TypePDEVs emulation type
Drive TypePDEVs drive type

Output example: HDD, FMD DC2, SCM, SSD

InterfacePDEVs control type

Output example: SAS, SATA, NVMe

RPMRevolutions per minute (unit: rpm)

A hyphen (-) indicates that the drive is not a hard disk drive (HDD).

Drive Type-CodeDrive type code of the drive to which the parity group belongs

Output example: SLB5E-M19RSS;SLB5G-M19RSS

If multiple drive types are configured, they are separated by semicolons (;).
Drive SizeDrive size (inches)

Output example: 2.5, 3.5

Drive CapacityPhysical drive capacity (GB or TB)
Drive VersionDrive firmware version
DKB1Name of the DKB1 controlling the PDEV
DKB2Name of the DKB2 controlling the PDEV
DKB3Name of the DKB3 controlling the PDEV
DKB4Name of the DKB4 controlling the PDEV
Serial Number#Serial number of this PDEV
RAID LevelRAID level of PDEVs

Output example: RAID1(2D+2D), RAID5(7D+1P), RAID6(14D+2P)

RAID Concatenation#0Number of parity group (#0) being concatenated to Physical drive Output example: 2-1, 3-1, 4-1
RAID Concatenation#1Number of parity group (#1) being concatenated to Physical drive Output example: 2-1, 3-1, 4-1
RAID Concatenation#2Number of parity group (#2) being concatenated to Physical drive Output example: 2-1, 3-1, 4-1
Resource Group NameName of the resource group to which the PDEV parity group belongs
Resource Group IDID of the resource group to which the PDEV parity group belongs (0 to 1023, decimal number)
EncryptionEncryption status of the parity group to which the PDEV belongs:
  • Enabled: Encryption is enabled
  • Disabled: Encryption is disabled

Ports report

Item Description
CHB Name of the channel board
Type Package type of the channel board
Port Location Name of the port on the channel board
iSCSI Virtual Port Mode Mode of the iSCSI virtual port
TCP Port Number Port number to use for a socket (decimal)
Internal WWN / Internal iSCSI Name Port WWN (16-digit hexadecimal) or iSCSI name of the port
Fabric One of the Fibre topology settings indicating the setting status of the Fabric switch

A hyphen (-) is displayed for mainframe ports.

Connection Type Fibre topology setting:
  • Point to Point
  • FC-AL

A hyphen (-) is displayed for mainframe ports.

IPv4 : IP Address IPv4 address of the port

Output example: 192.168.0.100

IPv4 : Subnet Mask IPv4 subnet mask of the port

Output example: 255.255.255.0

IPv4 : Default Gateway IPv4 default gateway of the port

Output example: 255.255.255.0

IPv6 : Mode IPv6 settings of the port (enabled or disabled)
IPv6 : Link Local Address IPv6 link local address of the port (16-digit hexadecimal)
IPv6 : Global Address IPv6 global address of the port.

Output example: xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx (hexadecimal)

IPv6 : Global Address 2 IPv6 global address 2 of the port.

Output example: xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx (hexadecimal)

IPv6 : Assigned Default Gateway Assigned IPv6 default gateway
Selective ACK Selective ACK mode (enabled or disabled)
Ethernet MTU Size (Byte) MTU settings (binary)

Output example: 1,500

Keep Alive Timer iSCSI keep alive timer (0 to 64,800) (sec)
VLAN : Tagging Mode Tagging mode of VLAN (enabled or disabled)
VLAN : ID Number of VLAN set to the port (1 to 4,094)
CHAP User Name User name for the CHAP authentication
iSNS Server : Mode iSNS mode settings (on or off)
iSNS Server : IP Address IP address of the iSNS server (30 to 65,535)
iSNS Server : TCP Port Number Number of the TCP port used in iSNS (binary)
Address (Loop ID) Fibre port address and Loop ID of the port

A hyphen (-) is displayed for mainframe ports.

Port Security Security of the port (enabled or disabled)

A hyphen (-) is displayed for mainframe ports.

Speed Data transfer speed of the port

A hyphen (-) is displayed for mainframe ports.

SFP Data Transfer Rate Maximum transfer rate of SFP which the mounted package supports.

Output example: 32G

T10 PI Mode

Indicates whether the T10 PI mode can be applied to the port.
  • Enabled
  • Disabled
  • Blank: The port type is a Fibre port other than 16FC2(CHB).
  • - (hyphen): iSCSI port
Resource Group Name Name of the resource group to which the port belongs
Resource Group ID ID of the resource group to which the port belongs (0 to 1023)
Number of Hosts Number of hosts registered to the port

A hyphen (-) is displayed for mainframe ports.

Number of LUNs Number of LU paths defined to the port

A hyphen (-) is displayed for mainframe ports.

Number of LDEVs Number of logical volumes that can be accessed through the port

A hyphen (-) is displayed for mainframe ports.

Number of PGs Number of parity groups having the logical volumes that can be accessed through the port

A hyphen (-) is displayed for mainframe ports.

Number of DKBs Number of disk boards controlling the parity group that contains the logical volumes that can be accessed through the port

A hyphen (-) is displayed for mainframe ports.

ModeOperation mode of the Fibre Channel port:
  • SCSI: SCSI port
  • NVMe: NVMe port
  • - (hyphen): The port that is not used for Fibre Channel.

This item is displayed only for VSP E1090.

Power Consumption report

Note
  • If the storage system is turned off, no records are created. If the system is in maintenance mode or if the SVP is rebooted, up to 2 hours of records could be lost.
  • If a failure occurs in the storage system, the correct information might not be output.
  • If the power and temperature information cannot be acquired due to a unit or network failure, a hyphen(-) is displayed.
  • For unimplemented DBs, the temperature information is blank.
Item Description
Date and TimeDate and time when the power or temperature information was recorded.
Power Consumption Average (W) Average of the power consumption
Power Consumption Maximum (W) Maximum of the power consumption
Power Consumption Minimum (W) Minimum of the power consumption
TEMP:DKC0-Cluster1 Average (°C) Average temperature of DKC0:CL1
TEMP:DKC0-Cluster1 Maximum (°C) Maximum temperature of DKC0:CL1
TEMP:DKC0-Cluster1 Minimum (°C) Minimum temperature of DKC0:CL1
TEMP:DKC0-Cluster2 Average (°C) Average temperature of DKC0:CL2
TEMP:DKC0-Cluster2 Maximum (°C) Maximum temperature of DKC0:CL2
TEMP:DKC0-Cluster2 Minimum (°C) Minimum temperature of DKC0:CL2

Example of Power Consumption report for VSP E590 or VSP E790 (for DB50)

Item for DB50Description
Date and TimeDate and time when the power or temperature information was recorded.
TEMP:DB50-DBPS50-1 Average (°C)Average temperature, maximum temperature, and minimum temperature of the DB for the two-hour period. Outputs in the following format:

TEMP:DBXX-DBPSXX-CL Average, Maximum, or Minimum (°C)

where

  • DBXX: DB location number

    The display format of the DB location number differs depending on the type and mount location of the DB:

    • DBXX: DBS/DBL/DB60 location number (decimal) (50 to 61)
    • DBXX&YY: DBS2 location number (decimal) (50&51, or 52&53)
  • DBPSXX-CL: DBPS location number
    • XX: XX in the DB location number (decimal) (00, or 50 to 61)
    • CL: DBPS number (1 or 2)
TEMP:DB50-DBPS50-1 Maximum (°C)
TEMP:DB50-DBPS50-1 Minimum (°C)
TEMP:DB50-DBPS50-2 Average (°C)
TEMP:DB50-DBPS50-2 Maximum (°C)
TEMP:DB50-DBPS50-2 Minimum (°C)

Example of Power Consumption report for VSP E990 (for DB01)

Item for DB01Description
Date and TimeDate and time when the power or temperature information was recorded.
TEMP:DB01-DBPS01-1 Average (°C)Average temperature, maximum temperature, and minimum temperature of the DB for the two-hour period. Outputs in the following format:

TEMP:DBXX-DBPSXX-CL Average, Maximum, or Minimum (°C)

where

  • XX: DB number (00 to 03)
  • CL: Cluster number (1 or 2)
TEMP:DB01-DBPS01-1 Maximum (°C)
TEMP:DB01-DBPS01-1 Minimum (°C)
TEMP:DB01-DBPS01-2 Average (°C)
TEMP:DB01-DBPS01-2 Maximum (°C)
TEMP:DB01-DBPS01-2 Minimum (°C)

Example of Power Consumption report for VSP E1090 (for DB69)

Item for DB01Description
Date and TimeDate and time when the power or temperature information was recorded.
TEMP:DB69-DBPS69-1 Average (°C)Average temperature, maximum temperature, and minimum temperature of the DB for the two-hour period. Outputs in the following format:

TEMP:DBXX-DBPSXX-CL Average, Maximum, or Minimum (°C)

where

  • DBXX: DB location number

    The display format of the DB location number differs depending on the type and mount location of the DB:

    • DBXX: DBN location number (decimal) (00 to 03), DBS, DBL, DB60 location number (decimal) (00 to 61)
    • DBXX&YY: DBS2 location number (decimal) (00&01, 02&03, 50&51, or 52&53)
  • DBPSXX-CL: DBPS location number
    • XX: DB location number (decimal) (00 to 69)
    • CL: DBPS number (1 or 2)
TEMP:DB69-DBPS69-1 Maximum (°C)
TEMP:DB69-DBPS69-1 Minimum (°C)
TEMP:DB69-DBPS69-2 Average (°C)
TEMP:DB69-DBPS69-2 Maximum (°C)
TEMP:DB69-DBPS69-2 Minimum (°C)

Spare Drives report

Item

Description

Drive Capacity

Capacity of the spare drive

Drive Type-Code

Type code of the spare drive

Location

Location of the spare drive

SSD Endurance report

Item

Description

Drive Type-Code

Type code of the drive

Drive Capacity

Capacity of the drive

Location

Location of the drive

Used Endurance Indicator (%)

The used endurance of SSD life (0 to 100)

The value of this indicator increases due to drive operation associated with internal processing of the storage system, and the host I/O. Even when no data is copied due to a drive failure, the value of this indicator increases because the spare drive also performs internal processing.

Storage System Summary report

Item Description
Storage System Type Type of the storage system
Serial Number Serial number of the storage system
IP Address IP address of the SVP
Software Versions Version of the following programs.

VSP E590, VSP E790:

  • Main
  • DKB
  • ROM BOOT
  • RAM BOOT
  • Expander
  • Config
  • CFM
  • HDD
  • Printout Tool
  • CHB (iSCSI)
  • CHB (FC32G)
  • GUM
  • CTL_NSW
  • CTL_eDKBN
  • DKBN (not supported by VSP E590 or VSP E790)
  • NSW (not supported by VSP E590 or VSP E790)

VSP E990:

  • Main
  • DKBN
  • NSW
  • ROM BOOT
  • RAM BOOT
  • Config
  • CFM
  • HDD
  • Printout Tool
  • CHB (iSCSI)
  • CHB (FC32G)
  • GUM
  • EDKBN

VSP E1090:

  • Main
  • CHB (iSCSI)
  • CHB (FC32G)
  • DKB
  • DKBN
  • EDKBN
  • GUM
  • ROM BOOT
  • RAM BOOT
  • Expander
  • NSW
  • Config
  • CFM
  • HDD
  • Printout Tool
Number of CUs The number of control units in the storage system
Shared Memory Size (GB) Capacity of shared memory

Includes the cache management information (directory)

Cache Size (GB) Capacity of the cache
Number of DKBs The number of disk boards on the module
System Options List of the system options specified for the storage system
Drive Capacity (TB) Total capacity of drives in the storage system except for external volumes
Spare Drive Capacity (TB) Total capacity of the spare drives in the storage system
Free Drive Capacity (GB) Total capacity of the free drives in the storage system
Volume Capacity (GB) List of the capacity of the open volumes

You cannot sort the list.

Number of LDEVs List of the numbers of the volumes in the following status.
  • Allocated
  • Unallocated
  • Reserved
  • V-VOL

You cannot sort the list.