Report examples: table view
Some Device Manager - Storage Navigator reports appear in table format.
The following figure provides examples of reports in table format. The icons are displayed before the names of the reports in table view. If the icons are not displayed correctly, update the window. To sort data in table reports, click any column header.
CHAP Users report
Item | Description |
Port Location | Name of the port |
User Name | Name of the CHAP user for authentication |
iSCSI Target Alias | Alias of the iSCSI target |
iSCSI Target Name | Name of the iSCSI target |
Disk Boards report
Item |
Description |
DKB |
Location of the disk board.
|
Number of PGs |
The number of the parity groups that the disk board controls.
|
Number of LDEVs (Total) |
The number of the logical volumes belonging to the parity groups that the disk board controls. |
Number of LDEVs (Unallocated) |
The number of the logical volumes that are inaccessible from the host and belong to the parity groups controlled by the disk board. |
Total LDEV Capacity (MB) |
Total capacity of the logical volumes belonging to the parity groups that the disk board controls. |
Unallocated LDEV Capacity (MB) |
Total capacity of the logical volumes that are inaccessible from the host and belong to the parity groups controlled by the disk board. |
Host Groups / iSCSI Targets report
Item |
Description |
Port Location | Name of the port |
Type | Type of the host group |
Host Group Name / iSCSI Target Alias | Name of the host group / alias of the iSCSI target |
Host Group ID / iSCSI Target ID | Number of the host group / ID of the iSCSI target |
iSCSI Target Name | Name of the iSCSI target |
Resource Group Name | Resource Group Name where the host group belongs |
Resource Group ID | Resource Group ID where the host group belongs |
Number of LUNs | The number of LU paths defined to the host group |
Number of LDEVs | The number of logical volumes that are accessible from the hosts in the host group |
Number of PGs | The number of parity groups with logical volumes that are accessible from the hosts in the host group |
Number of DKBs | The number of disk boards controlling the parity groups where the logical volumes that are accessible from the hosts in the host group belong |
Total LDEV Capacity (MB) | Total capacity of the logical volumes accessible from the hosts in the host group. This is the total capacity of LDEVs referred to in "Number of LDEVs". |
Port Security | Security of the port |
Authentication : Method |
iSCSI target method authentication settings
|
Authentication : Mutual CHAP |
Enable or disable the iSCSI target mutual CHAP
|
Authentication : User Name | Authenticated iSCSI target user name |
Authentication : Number of Users | The number of authenticated users registered in the iSCSI target |
Host Mode | Host mode of the host group |
Host Mode Option | Host mode option of the host group. Host mode options are separated by semicolons (;) when more than one option is specified. |
Number of Hosts | The number of the hosts in the host group. |
Hosts report
Item |
Description |
Port Location | Name of the port |
Type | Port type |
Port Internal WWN | Port WWN |
Port Security | Port security setting |
Host Group Name / iSCSI Target Alias | Name of the host group / alias of the iSCSI target |
iSCSI Target Name | Name of the iSCSI target |
Host Mode | Host mode of the host group |
Host Mode Option | Host group host mode option. When more than one host mode option is specified, they are separated by semicolons (;) |
Host Name | Name of the host that can access the LU path through the port |
HBA WWN / iSCSI Name | Host WWN / host iSCSI name. The name is in 16-digit hex format. |
Logical Devices report
Item |
Description |
LDEV ID |
The logical volume number |
LDEV Name |
The logical volume name |
Capacity (MB) |
Capacity of the logical volume |
Emulation Type |
Emulation type of the logical volume |
Resource Group Name |
Name of the resource group to which the LDEV belongs |
Resource Group ID |
ID of the resource group to which the LDEV belongs |
PG |
Number of the parity group to which the LDEV belongs.
|
RAID Level |
RAID level of the parity group to which the LDEV belongs1 |
Drive Type/RPM |
Drive type, drive control name, and revolutions-per-minute (RPM) of the drive of the parity group to which the LDEV belongs. A hyphen (-) is displayed as RPM when the drive is SSD.1 For VSP E990, this item is displayed as Drive Type/Interface. |
Drive Type-Code |
Type code of the drives in the parity group to which the logical volume belongs1 |
Drive Capacity |
Capacity of the drives in the parity group to which the LDEV belongs1 |
PG Members |
Drive locations of the parity group to which the LDEV belongs1 |
Allocated |
Information about whether the host can access the LDEV:
|
SSID |
SSID of the LDEV |
CVS |
Information about whether the LDEV is a custom-size volume |
OCS |
Oracle checksum |
Attribute |
Attribute of the LDEV |
Provisioning Type |
Provisioning type of the LDEV |
Pool Name |
|
Pool ID |
ID of the pool indicated by "Pool Name". A hyphen (-) is displayed for volumes other than pool-VOLs or V-VOLs. |
Current MPU |
Number of the MP unit that currently controls the LDEV |
Setting MPU |
Number of the MP unit that you specified to control the LDEV |
Command Device: Security |
Indicates whether Security is specified as the attribute for the command device. A hyphen (-) is displayed when "Attribute" is not "CMDDEV". |
Command Device: User Authentication |
Indicates whether User Authentication is specified as the attribute for the command device. A hyphen (-) is displayed when "Attribute" is not "CMDDEV". |
Command Device: Device Group Definition |
Indicates whether Device Group Definition is specified as the attribute for the command device. A hyphen (-) is displayed when "Attribute" is not "CMDDEV". |
Encryption |
Indicates whether the parity group to which the LDEV belongs is encrypted:
|
T10 PI |
Indicates the T10 PI attribute set for the LDEV:
|
ALUA Mode |
Indicates whether the ALUA mode is enabled:
|
Notes:
|
LUNs report
Item |
Description |
Port Location |
Name of the port |
HBA WWN / iSCSI Name |
Port WWN or name of the iSCSI (16 digits in hexadecimal) |
Port Security |
Name of the type of security of the port |
Host Group Name / iSCSI Target Alias |
Name of the host group or alias of the iSCSI target |
iSCSI Target Name |
Name of the iSCSI target |
Host Mode |
Host mode of the host group |
Host Mode Option |
Host mode option of the host group. Host mode options are separated by semicolons (;) when more than one option is specified. |
LUN |
Logical unit number |
LDEV ID |
Logical volume number |
Emulation Type |
Emulation type of the logical volume |
Capacity (MB) |
Capacity of the logical volume |
Asymmetric Access State |
Asymmetric access status:
|
MP Units report
Item |
Description |
MP Unit ID |
MP unit ID |
Auto Assignment |
Auto assignment attribute for the MP unit |
Number of Resources (LDEV) |
Number of LDEVs that the MP unit controls |
Number of Resources (Journal) |
Number of journals that the MP unit controls |
Number of Resources (External Volume) |
Number of external volumes that the MP unit controls (includes volumes for FICON DM) |
Number of Resources (Total) |
The total number of resources that the MP unit controls. It is the total of Number of Resources (LDEV), Number of Resources (Journal), and Number of Resources (External Volume). |
MP Unit Details report
Item |
Description |
MP Unit ID |
MP unit ID |
Auto Assignment |
Auto assignment attribute for the MP unit |
Resource ID |
ID of this resource that the MP unit controls |
Resource Name |
The name of the resource that the MP unit controls. If "Type" is LDEV, the LDEV name that is set is displayed. A hyphen (-) displays for journal volumes or external volumes. |
Type |
The type of the resource that the MP unit controls |
Parity Groups report
Item |
Description |
PG |
Parity group number
|
DKB |
Name of the disk board that controls the parity group1 |
RAID Level |
RAID level of the parity group1 |
Resource Group Name |
Name of the resource group in which the parity group belongs |
Resource Group ID |
ID for the resource group in which the parity group belongs |
Emulation Type |
Emulation type of the parity group |
Number of LDEVs (Total) |
The number of the logical volumes in the parity group |
Number of LDEVs (Unallocated) |
The number of the logical volumes in the parity group that the host cannot access |
Total LDEV Capacity (MB) |
Capacity of the logical volumes in the parity group |
Unallocated LDEV Capacity (MB) |
Capacity of the logical volumes in the parity group that the host cannot access |
Drive Type-Code |
The type code of the drive in the parity group.
|
Drive Type/Interface/RPM |
Drive type, drive control name, and revolutions-per-minute (RPM) of the drive in the parity group where the LDEV belongs1 A hyphen (-) is displayed instead of the RPM when the drive is an SSD or FMD. For VSP E990, this item is displayed as Drive Type/Interface. |
Drive Capacity |
Capacity of the drive in the parity group1 |
RAID Concatenation #0 |
The number indicating a parity group #0 connected to this parity group1,2 |
RAID Concatenation #1 |
The number indicating a parity group #1 connected to this parity group1,2 |
RAID Concatenation #2 |
The number indicating a parity group #1,2 connected to this parity group1,2 |
Encryption |
Indicates whether the parity group is encrypted.
|
Accelerated Compression |
Accelerated compression of the parity group
|
Notes:
|
PDEVs report
The following table describes the items in the PDEVs report.
Item |
Description |
Location | PDEV name |
CR# |
C# and R# (2-digit hexadecimal numbers that identify the PDEV Output in the format XX/YY, where:
|
PG | PDEVs parity group |
Emulation Type | PDEVs emulation type |
Drive Type | PDEVs drive type Output example: HDD, FMD DC2, SCM, SSD |
Interface | PDEVs control type Output example: SAS, SATA, NVMe |
RPM | Revolutions per minute Output example: 7200, 10000, 15000 A hyphen (-) indicates that the drive is not a hard disk drive (HDD). |
Drive Type-Code | Drive type code of the drive to which the parity group belongs Output example: SLB5E-M19RSS;SLB5G-M19RSS If multiple drive types are configured, they are separated by semicolons (;). |
Drive Size | Drive size (inches) Output example: 2.5, 3.5 |
Drive Capacity | Physical drive capacity (GB or TB) |
Drive Version | Drive firmware version |
DKB1 | Name of the DKB1 controlling the PDEV |
DKB2 | Name of the DKB2 controlling the PDEV |
DKB3 | Name of the DKB3 controlling the PDEV |
DKB4 | Name of the DKB4 controlling the PDEV |
Serial Number# | Serial number of this PDEV |
RAID Level | RAID level of PDEVs Output example: RAID1(2D+2D), RAID5(7D+1P), RAID6(14D+2P) |
RAID Concatenation#0 | Number of parity group (#0) being concatenated to Physical drive Output example: 2-1, 3-1, 4-1 |
RAID Concatenation#1 | Number of parity group (#1) being concatenated to Physical drive Output example: 2-1, 3-1, 4-1 |
RAID Concatenation#2 | Number of parity group (#2) being concatenated to Physical drive Output example: 2-1, 3-1, 4-1 |
Resource Group Name | Name of the resource group to which the PDEV parity group belongs |
Resource Group ID | ID of the resource group to which the PDEV parity group belongs (0 to 1023, decimal number) |
Encryption | Encryption status of the parity group to which the PDEV belongs:
|
Ports report
Item |
Description |
CHB | Name of the channel board |
Type | Package type of the channel board |
Port Location | Name of the port on the channel board |
iSCSI Virtual Port Mode | Mode of the iSCSI virtual port |
TCP Port Number | Port number to use for a socket (decimal) |
Internal WWN / Internal iSCSI Name | WWN / iSCSI name of the port |
Fabric | One of the Fibre topology settings indicating the setting status of the Fabric switch |
Connection Type | One of the Fibre topology settings
|
IPv4 : IP Address |
IPv4 address of the port Output example: 192.168.0.100 |
IPv4 : Subnet Mask |
IPv4 subnet mask of the port Output example: 255.255.255.0 |
IPv4 : Default Gateway |
IPv4 default gateway of the port Output example: 255.255.255.0 |
IPv6 : Mode | IPv6 settings of the port
|
IPv6 : Link Local Address | IPv6 link local address of the port (16-digit hexadecimal) |
IPv6 : Global Address |
IPv6 global address of the port. Output example: xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx (hexadecimal) |
IPv6 : Global Address 2 |
IPv6 global address 2 of the port. Output example: xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx (hexadecimal) |
IPv6 : Assigned Default Gateway | Assigned IPv6 default gateway |
Selective ACK | Selective ACK mode
|
Ethernet MTU Size (Byte) | MTU settings (binary)
|
Keep Alive Timer | iSCSI keep alive timer (0 to 64,800) (sec) |
VLAN : Tagging Mode | Tagging mode of VLAN
|
VLAN : ID | Number of VLAN set to the port (1 to 4,094) |
CHAP User Name | User name for the CHAP authentication |
iSNS Server : Mode | iSNS mode settings
|
iSNS Server : IP Address | IP address of the iSNS server (30 to 65,535) |
iSNS Server : TCP Port Number | Number of the TCP port used in iSNS (binary) |
Address (Loop ID) | Fibre port address and Loop ID of the port |
Port Security | Security of the port
|
Speed | Data transfer speed of the port |
SFP Data Transfer Rate | Maximum transfer rate of SFP which the mounted package
supports.
|
T10 PI Mode |
Indicates whether the T10 PI mode can be applied to the port.
|
Resource Group Name | Name of the resource group to which the port belongs |
Resource Group ID | ID for the resource group to which the port belongs (0 to 1023) |
Number of Hosts | The number of the hosts registered to the port |
Number of LUNs | The number of the LU paths defined to the port |
Number of LDEVs | The number of the logical volumes that can be accessed through the port |
Number of PGs | The number of the parity groups having the logical volumes that can be accessed through the port |
Number of DKBs | The number of the disk boards controlling the parity group that contains the logical volumes that can be accessed through the port |
Power Consumption report
No records are created if the storage system is turned off. If the system is in maintenance mode or the SVP is rebooted, up to two hours of records could be lost.
If a failure occurs in the storage system, the correct information might not be output.
A hyphen(-) is displayed if the power and temperature information cannot be acquired due to a unit or network failure.
Item |
Description |
Power Consumption Average (W) |
Average of the power consumption |
Power Consumption Maximum (W) |
Maximum of the power consumption |
Power Consumption Minimum (W) |
Minimum of the power consumption |
TEMP:HSNBX0-HSNPANEL0 Average (degrees C) | Average temperature of HSNBX0:HSNPANEL0 |
TEMP:HSNBX0-HSNPANEL0 Maximum (degrees C) | Maximum temperature of HSNBX0:HSNPANEL0 |
TEMP:HSNBX0-HSNPANEL0 Minimum (degrees C) | Minimum temperature of HSNBX0:HSNPANEL0 |
TEMP:HSNBX1-HSNPANEL1 Average (degrees C) | Average temperature of HSNBX1:HSNPANEL1 |
TEMP:HSNBX1-HSNPANEL1 Maximum (degrees C) | Maximum temperature of HSNBX1:HSNPANEL1 |
TEMP:HSNBX1-HSNPANEL1 Minimum (degrees C) | Minimum temperature of HSNBX1:HSNPANEL1 |
TEMP:DKC0-Cluster1 Average (degrees C) |
Average temperature of DKC0:CL1 |
TEMP:DKC0-Cluster1 Maximum (degrees C) |
Maximum temperature of DKC0:CL1 |
TEMP:DKC0-Cluster1 Minimum (degrees C) |
Minimum temperature of DKC0:CL1 |
TEMP:DKC0-Cluster2 Average (degrees C) |
Average temperature of DKC0:CL2 |
TEMP:DKC0-Cluster2 Maximum (degrees C) |
Maximum temperature of DKC0:CL2 |
TEMP:DKC0-Cluster2 Minimum (degrees C) |
Minimum temperature of DKC0:CL2 |
Item |
Description |
TEMP:DB00-DBPS00-1 Average (Temperature in degrees C) TEMP:DB00-DBPS00-1 Maximum (Temperature in degrees C), TEMP:DB00-DBPS00-1 Minimum (Temperature in degrees C), TEMP:DB00-DBPS00-2 Average (Temperature in degrees C), TEMP:DB00-DBPS00-2 Maximum (Temperature in degrees C), TEMP:DB00-DBPS00-2 Minimum (Temperature in degrees C) |
Average temperature, maximum temperature, and minimum temperature of the DB for the two-hour period. Outputs in the following format: TEMP:DB XX -DBPS XX -CL Average, Maximum, or Minimum (Temperature in degrees Celsius)
00 to 07 (VSP F350, VSP G350) 00 to 11 (VSP F370, VSP G370) 00 to 47 (VSP F700, VSP F900, VSP G700, VSP G900) 00 to 03 (VSP E990)
|
Spare Drives report
Item |
Description |
Drive Capacity |
Capacity of the spare drive |
Drive Type-Code |
Type code of the spare drive |
Location |
Location of the spare drive |
SSD Endurance report
Item |
Description |
Drive Type-Code |
Type code of the drive |
Drive Capacity |
Capacity of the drive |
Location |
Location of the drive |
Used Endurance Indicator (%) |
The used endurance of SSD life (0 to 100) The value of this indicator increases due to drive operation associated with internal processing of the storage system, and the host I/O. Even when no data is copied due to a drive failure, the value of this indicator increases because the spare drive also performs internal processing. |
Storage System Summary report
Item |
Description |
Storage System Type |
Type of the storage system |
Serial Number |
Serial number of the storage system |
IP Address |
IP address of the SVP |
Software Versions |
Version of the following programs. For VSP G130, G/F350, G/F370, G/F700, G/F900
For VSP E990
|
Number of CUs |
The number of control units in the storage system |
Shared Memory Size (GB) |
Capacity of shared memory Includes the cache management information (directory) |
Cache Size (GB) |
Capacity of the cache |
Number of DKBs |
The number of disk boards on the module |
System Options |
List of the system options specified for the storage system |
Drive Capacity (TB) |
Total capacity of drives in the storage system except for external volumes |
Spare Drive Capacity (TB) |
Total capacity of the spare drives in the storage system |
Free Drive Capacity (GB) |
Total capacity of the free drives in the storage system |
Volume Capacity (GB) 1 |
List of the capacity of the open volumes |
Number of LDEVs1 |
List of the numbers of the volumes in the following status.
|
Notes:
|