The storage system use the following specifications.

The Hitachi Virtual Storage Platform 5000 series(VSP 5000 series) storage systems are designed to operate in a controlled environment such as a data center. The following tables provide the environmental, electrical, and physical requirements and specifications for the storage systems.

Storage system specifications

The following table lists the technical specifications of the Hitachi Virtual Storage Platform 5000 series storage system.

Item

Specification

System

2.5-inch SAS HDD/SSD

Maximum number of drives

2-node system: 768

4-node system: 1,536

6-node system: 2,304

3.5-inch SAS HDDs

Maximum number of drives

2-node system: 384

4-node system: 768

6-node system: 1,152

Number of FMDs

Maximum number of drives

2-node system: 192

4-node system: 384

6-node system: 576

Number of NVMe drives

Maximum number of SSDs

2-node system: 96

4-node system: 192

6-node system: 288

Maximum number of SCM drives

2-node system: 33

4-node system: 66

6-node system: 99

RAID group configuration

RAID 6

  • 6D+2P
  • 14D+2P
RAID 5

  • 3D+1P
  • 7D+1P
RAID 1 (RAID 1+0)

  • 2D+2D
  • 4D+4D

Maximum number of spare drives

2-node system: 64

4-node system: 128

6-node system: 192

Maximum number of volumes

65,280

Maximum storage system capacity (physical capacity) (30-TB 2.5-inch SAS SSDs)

2-node system: 23.1 PB (20.5 PiB)

4-node system: 46.2 PB (41 PiB

6-node system: 69.3 PB (61.5 PiB)

Maximum external configuration

255 PiB

Memory

Cache memory capacity

512 GiB to 6,144 GiB

Storage interface

Controller-drive box (DKC-DB) interface

SAS/Dual Port

NVMe/Dual Port

(SAS and NVMe cannot be intermixed within each node pair.)

Data transfer rate

SAS Interface

12 Gbps

NVMe (PCIe) Interface8 Gbps

Maximum number of back-end modules (BEMs) (also called disk boards, or DKBs

2-node system: 8

4-node system: 16

6-node system: 24

Device interface Channel typeOpen Systems

Fibre Channel Shortwave

Fibre Channel Longwave*

iSCSI (Optic)

Mainframe

Fibre Channel Shortwave

Fibre Channel Longwave *

Data trasfer rate

Fibre Channel

Open System : 4/8/16/32 Gbps

Mainframe : 4/8/16 Gbps

iSCSI (Optic)

10 Gbps

Maximum number of CHB

2-node system: 16

2-node system: 32

6-node system: 48

*Longwave is not supported on 32 Gbps Fibre Channel.

Physical specifications

The following table provides power consumption, heat output, and airflow specifications of the individual Virtual Storage Platform 5000 series system components.

Component

Component model number

Power consumption

(VA)

Heat output

Airflow

(m3/min)

Weight

(kg)

Primary controller chassis DKC910I-CBX9208745.470.0
Secondary controller chassis DKC-F910I-CBX24694463.041.6

SFF drive chassis 

DKC-F910I-SBX

1,221

1,160

12.8

68

LFF drive chassis 

DKC-F910I-UBX

674

640

18.9

126.0

FMD Drive Chassis

DKC-F910I-FBX

473

450

6.4

76.7

Controller Chassis Bezel

DKC-F910I-CBLFB

-

-

-

1.0

Controller Chassis Bezel

DKC-F910I-CBLFBA

-

-

-

1.2

Drive Chassis Bezel

DKC-F910I-DBFB

-

-

-

0.5

Drive Chassis Bezel

DKC-F910I-DBFBA

-

-

-

0.5

HSN Chassis Bezel

DKC-F910I-HSNFB

-

-

-

0.6

HSN Chassis Bezel

DKC-F910I-HSNFBA

-

-

-

0.6

Flash Module Bezel

DKC-F910I-FBFB

-

-

-

0.7

Flash Module Bezel

DKC-F910I-FBFBA

-

-

-

0.9

Additional Service Processor

DKC-F910I-SVP

16.0

16.0

-

0.7

Additional RAID Controller Kit DKC-F910I-CTL390370

-

11.4
Safety Cover for empty CTL slotDKC-F910I-SCFC

-

-

-

1.8

Additional Hub

DKC-F910I-HUB

12.0

12.0

-

0.5

Fan Module

DKC-F910I-FANM

22.7

21.6

-

1.1

Operation Panel Kit

DKC-F910I-OPPNL

1.0

1.0

-

0.37

Mainframe Fibre 4-port 16G Host Adapter for Shortwave

DKC-F910I-4MS16

19.3

18.3

-

0.5

Mainframe Fibre 4-port 16G Host Adapter for Longwave

DKC-F910I-4ML16

19.3

18.3

-

0.5

Fibre 4-port 32Gbps Ready Host Adapter

DKC-F910I-4HF32R

24.9

22.4

-

0.5

iSCSi 2-port 10G Host Adapter

DKC-F910I-2HS10S

18.9

18.0

-

0.5

SFP for 16Gbps Longwave

DKC-F810I-1PL16

-

-

-

0.02

SFP for 16Gbps Shortwave

DKC-F810I-1PS16

-

-

-

0.02

SFP for 32Gbps Shortwave

DKC-F810I-1PS32

-

-

-

0.02

Disk Adapter

DKC-F910I-BS12G

17.2

16.0

-

0.5

Encryption Disk Adapter

DKC-F910I-BS12GE

17.2

16.0

-

0.5

Cache Memory 64GB

DW-F850-CM64GL5.04.8-

0.054

Cache Flash Memory 45

DKC-F910I-BM45

6.8

6.5

-

0.2

Cache Flash Memory 45 with encryption

DKC-F910I-BM4E

6.8

6.5

-

0.2

Rack Rail

A34V-600-850-UNI-S.P

-

-

-

-

HSN Chassis Rail

3292455-001

-

-

-

-

Rack Rail

A34V-600-850-UNI-S.P

-

-

-

-

Drive Chassis Rail for FBX

A3BF-HK-GL-740-1-S.P L

-

-

-

-

PCIe Cable set for primary module CBXA

DKC-F910I-MCC1

-

-

-

0.1

PCIe Cable set for primary module CBXB

DKC-F910I-MCC2

-

-

-

0.1

PCIe Cable 5m

DKC-F910I-MFC5

-

-

-

0.2

PCIe Optical Module

DKC-F910I-PQSFP

-

-

-

0.005

SAS Optical Module

DKC-F910I-SQSFP

-

-

-

0.005

Optical Cable 10m

DKC-F910I-MPC10

-

-

-

0.2

Optical Cable 20m

DKC-F910I-MPC20

-

-

-

0.3

Optical Cable 30m

DKC-F910I-MPC30

-

-

-

0.4

Optical Cable 100m

DKC-F910I-MPC1H

-

-

-

1.0

SAS Cable set for Disk Adapter

DKC-F910I-SCCS

-

-

-

1.4

QSFP Metal Cable 1m

DW-F800-SCQ1

-

-

-

0.2

QSFP Metal Cable 1.5m

DW-F800-SCQ1F

-

-

-

0.2

RJ45 bundled LAN Cable Kit

DKC-F910I-LC

-

-

-

0.2

RJ45 Cable 5m

DKC-F910I-LC5

-

-

-

0.3

RJ45 Cable 10m

DKC-F910I-LC10

-

-

-

0.5

RJ45 Cable 20m

DKC-F910I-LC20

-

-

-

0.9

RJ45 Cable 30m

DKC-F910I-LC30

-

-

-

1.4

RJ45 Cable 100m

DKC-F910I-LC1J

-

-

-

4.7

SFF 2.4TB Disk Drive

DKC-F810I-2R4JGM

9.4

9.0

-

0.26

LFF 14TB Disk Drive

DKC-F810I-14RH9M

13.5

12.9

-

0.86

SFF 960GB SSD Drive

DKC-F810I-960MGM

7.0

6.7

-

0.21

SFF 1.9TB SSD Drive

DKC-F810I-1T9MGM

7.0

6.7

-

0.21

SFF 3.8TB SSD Drive

DKC-F810I-3R8MGM

7.0

6.7

-

0.21

SFF 7.6TB SSD Drive

DKC-F810I-7R6MGM

8.3

7.9

-

0.21

SFF 15TB SSD Drive

DKC-F810I-15RMGM

8.3

7.9

-

0.21

SFF 30TB SSD Drive

DKC-F810I-30RMGM

8.3

7.9

-

0.21

7TB Flash Module Drive

DKC-F810I-7R0FP

26.0

25.0

-

1.4

14TB Flash Module Drive

DKC-F810I-14RFP

26.0

25.0

-

1.4

NVMe Disk Adapter

DKC-F910I-BN8G

17.1

16.2

-

0.5

NVMe SFF Drive Chassis

DKC-F910I-NBX

1221

1160

16.4

62

NVMe Chassis Rail

A3BF-HK-GL-740-1-S.P

-

-

-

-

NVMe Cable set for NVMe Disk Adapter

DKC-F910I-NCCS

-

-

-

1.1

SFF 1.9TB NVMe Drive

DKC-F910I-1R9RVM

20

19

-

0.21

SFF 3.8TB NVMe Drive

DKC-F910I-3R8RVM

20

19

-

0.21

SFF 7.6TB NVMe Drive

DKC-F910I-7R6RVM

20

19

-

0.21

SFF 15TB NVMe Drive

DKC-F910I-15RRVM

20

19

-

0.21

SFF 30TB NVMe Drive

DKC-F910I-30RRVM

20

19

-

0.21

SCM 375GB NVMe DriveDKC-F910I-375YVM

20

19

-

0.19

  1. Maximum values when all fans rotate at the maximum speed.

Electrical specifications

The Hitachi Virtual Storage Platform 5000 series storage system Power Distribution Units (PDUs) support single-phase AC power.

The Hitachi rack comes with either two, four, or six PDUs, depending on the PDU model selected. The PDUs are installed vertically in the rack.

  • If two PDUs are selected, one will be installed on the left side of the rack and the other will be installed on the right side.
  • If four PDUs are selected, the PDUs will be half-length and mounted vertically, one above the other, with two on the left side of the rack and two on the right side.
  • If six PDUs are selected, the PDUs will be 1/3-length and mounted vertically, one above the other, with three on the left side of the rack and two on the right side.
NoteThe current and power specifications of the storage system in the following tables were measured in a controlled environment. To calculate the power and current draw, and heat output of a specific system, see Physical specifications or use the weight and power calculator at the following URL:https://www.hitachivantara.com/ext/weight-and-power-calculator.html .

If you need assistance using this tool, contact Hitachi Vantara Support athttps://support.hitachivantara.com/en/contact-support.html .

Item Input Power Inrush Current (Rating) 1 Leakage Current Inrush Current
When one PS is operating When two PSs are operating 1st (0-p) 2nd (0-p) 1st (0-p) Time (-25%)
Node power supply Single phase, AC200V to AC240V 7.2 A 3.6 A 1.75 mA 30 A 30 A25 ms
DBPS (DBS2) 3.2 A 1.6 A 1.75 mA 30 A30 A25 ms
DBPS (DBL) 2.0 A 1.0 A 1.75 mA 30 A30 A25 ms
DBPS (DBF3) 3.1 A 1.55 A 1.75 mA 20 A 15 A 80 ms
DBPS (DBN)4.0 A2.0 A1.75 mA 30 A30 A25 ms
Node interconnect switch power supply 1.2 A 0.6 A 1.75 mA 30 A 30 A25 ms
  1. When two power supplies are operating, each power supply provides about half of the required power for the storage system. When only one of the two power supplies is operating, the power supply provides all required power for the storage system. Therefore, use the power supplies that meet the rated input current for when one power supply is operating.

The following table shows the supported input voltage and frequency for the controller chassis, drive box, and node interconnect switch.

Input voltage Voltage tolerance Frequency Wire connection
200V to 240V +10% or -11%

50Hz ± 2Hz

60Hz ± 2Hz

1 Phase 2 Wire + Ground
  • Use PDU with the standard plug.
  • If PDU is provided with connecting type B plug, use PDU with circuit breaker of 20 (16) A or less, or install circuit breaker of 20 (16) A in the power supply.

Environmental specifications

The following table lists the environmental specifications for the Hitachi Virtual Storage Platform 5000 series storage systems.

NoteEnvironmental conditions of operation should be completed before switch on a system
Environmental specifications

Item

Condition

Operating

Not operating

Shipping and storage

Temperature range

10 ºC to 40 ºC6

-10 ºC to 50 ºC

-30 ºC to 6 0ºC

Relative Humidity (No dew condensation)

8% to 80%

8% to 90%

5% to 95%

Max. Wet Bulb

29 ºC

29 ºC

29 ºC

Temperature gradient per hour

10 ºC

10 ºC

10 ºC

Dust

0.15 or less

-

-

Gaseous contaminants2

G1 classification levels

Altitude (m)

3 ~ 3,050

(10 ºC ~ 28 ºC)

~ 950

(10 ºC ~ 40 ºC)6

-60 to 3,000

-60 to 3,000

Noise Level

(Recommended)

90 dB or less1

-

-

Chassis Acoustic Level 45

  • CBX: LpAm 60dB, LwA 6.6Bel
  • HSNBX: LpAm 60dB, LwA 6.6Bel
  • DBS2: LpAm 60dB, LwA 6.4Bel
  • DBL: LpAm 60dB, LwA 6.4Bel
  • DBF3: LpAm 60dB, LwA 6.0Bel
  • DBN: LpAm 60dB, LwA 6.0Bel
  • CBX: LpAm 55dB
  • HSNBX: LpAm 55dB
  • DBS2: LpAm 55dB
  • DBL: LpAm 55dB
  • DBF3: LpAm 55dB
  • DBN: LpAm 55dB

-

  1. Fire suppression systems and acoustic noise: Hitachi does not test storage systems and hard disk drives for compatibility with fire suppression systems and pneumatic sirens. Hitachi also does not provide recommendations or claim compatibility with any fire suppression systems and pneumatic sirens. Customer is responsible to follow their local or national regulations.
  2. See ANSI/ISA-71.04-2013 Environmental Conditions for Process Measurement and Control Systems: Airborne Contaminants.
  3. Meets the highest allowable temperature conditions and complies with ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) 2011 Thermal Guidelines Class A2. The maximum value of the ambient temperature and the altitude is from 35 degrees C at an altitude of 950 meters (3000 feet) to 28 degrees C at an altitude of 3050 meters (10000 feet). The allowable ambient temperature is decreased by 1 degree C for every 300-meter increase in altitude above 950 meters.
  4. The acoustic level is measured under the following conditions in accordance with ISO7779 and the value is declared based on ISO9296.

    In a normal installation area (data center/general office), the storage system is surrounded by different elements from the following measuring conditions according to ISO, such as noise sources other than the storage system (other devices) , the walls and ceilings that reflect the sound.

    Therefore, the values described in the table do not guarantee the acoustic level in the actual installation area.

    • Measurement environment: In a semi-anechoic room whose ambient temperature is 23 degrees C ± 2 degrees C

    • Device installation position: The Controller Chassis is at the bottom of the rack and the Drive Box is at a height of 1.5 meters in the rack

    • Measurement position: 1 meter away from the front, rear, left, or right side of the storage system and 1.5 meters high (at four points)

    • Measurement value: Energy average value of the four points (front, rear, left, and right)
  5. Sound pressure level [LA] changes from 45 dB to 63 dB according to the ambient temperature, drive configuration and operating status. The maximum could be 67 dB during maintenance procedure for failed ENC or Power Supply.

  6. NVMe drives have a temperature range from 10 ºC to 35 ºC while in operation.

Mechanical environmental specifications

The following tables list the mechanical environmental conditions for the Hitachi Virtual Storage Platform 5000 series storage systems.

Mechanical environmental conditions

Item

In operation

In non-operation

Vibration value of storage system

0.25Grms, 5-500Hz, 30min.

0.6Grms, 3-500Hz, 30min.

Vibration value of chassis

-

  • 5G, 11ms half sine, 3axis direction
  • 10G, 6ms, half sine, 3axis direction
  • 10G, 11ms, half sine, bottom direction