Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

Report examples: table view

Some Device Manager - Storage Navigator reports appear in table format.

The following figure provides examples of reports in table format. The GUID-6E7A0CA5-8D25-488F-AAF7-55B9446F25B8-low.gif icons are displayed before the names of the reports in table view. If the icons are not displayed correctly, update the window. To sort data in table reports, click any column header.

GUID-F5600162-28B6-41C5-8798-1A11A94C99D5-low.png

CHAP Users report

The following figure shows an example of a CHAP Users report. The table following the figure describes the items in the report.

GUID-928C4B72-2112-4F0C-9BB2-737A4F67E7AF-low.png
Item Description
Port Location Name of the port
User Name Name of the CHAP user for authentication
iSCSI Target Alias Alias of the iSCSI target
iSCSI Target Name Name of the iSCSI target

Disk Boards report

The following figure shows an example of a Disk Boards report. The table following the figure describes the items in the report.

GUID-556768F6-A26B-4A81-982D-7E2F629A0D85-low.png

Item

Description

DKB

Location of the disk board.

  • "External" is displayed when the storage system has an external storage system.
  • "External (FICON DM)" is displayed when the storage system has volumes for FICON DM.

Number of PGs

The number of the parity groups that the disk board controls.

  • If "DKB" is "External", this item indicates the number of parity groups mapped to external volumes.
  • If "DKB" is "External (FICON DM)", this item indicates the number of parity groups mapped to volumes for FICON DM.

Number of LDEVs (Total)

The number of the logical volumes belonging to the parity groups that the disk board controls.

Number of LDEVs (Unallocated)

The number of the logical volumes that are inaccessible from the host and belong to the parity groups controlled by the disk board.

Total LDEV Capacity (MB)

Total capacity of the logical volumes belonging to the parity groups that the disk board controls.

Unallocated LDEV Capacity (MB)

Total capacity of the logical volumes that are inaccessible from the host and belong to the parity groups controlled by the disk board.

Host Groups / iSCSI Targets report

The following figure shows an example of a Host Groups / iSCSI Targets report. The table following the figure describes the items in the report.

GUID-5D63919B-156C-42E6-A1C7-EB0A02C7E1A7-low.png

Item

Description

Port Location Name of the port
Type Type of the host group
Host Group Name / iSCSI Target Alias Name of the host group / alias of the iSCSI target
Host Group ID / iSCSI Target ID Number of the host group / ID of the iSCSI target
iSCSI Target Name Name of the iSCSI target
Resource Group Name Resource Group Name where the host group belongs
Resource Group ID Resource Group ID where the host group belongs
Number of LUNs The number of LU paths defined to the host group
Number of LDEVs The number of logical volumes that are accessible from the hosts in the host group
Number of PGs The number of parity groups with logical volumes that are accessible from the hosts in the host group
Number of DKBs The number of disk boards controlling the parity groups where the logical volumes that are accessible from the hosts in the host group belong
Total LDEV Capacity (MB) Total capacity of the logical volumes accessible from the hosts in the host group. This is the total capacity of LDEVs referred to in "Number of LDEVs".
Port Security Security of the port
Authentication : Method

iSCSI target method authentication settings

  • CHAP
  • None
  • Comply with Host Setting
Authentication : Mutual CHAP

Enable or disable the iSCSI target mutual CHAP

  • Enabled
  • Disabled
Authentication : User Name Authenticated iSCSI target user name
Authentication : Number of Users The number of authenticated users registered in the iSCSI target
Host Mode Host mode of the host group
Host Mode Option Host mode option of the host group. Host mode options are separated by semicolons (;) when more than one option is specified.
Number of Hosts The number of the hosts in the host group.

Hosts report

The following figure shows an example of a hosts report. The table following the figure describes the items in the report. When a host is registered to more than one port, more than one record shows information about the same host.

GUID-735430D2-8E39-40E1-8DFA-55AE2A2387BB-low.png

Item

Description

Port Location Name of the port
Type Port type
Port Internal WWN Port WWN
Port Security Port security setting
Host Group Name / iSCSI Target Alias Name of the host group / alias of the iSCSI target
iSCSI Target Name Name of the iSCSI target
Host Mode Host mode of the host group
Host Mode Option Host group host mode option. When more than one host mode option is specified, they are separated by semicolons (;)
Host Name Name of the host that can access the LU path through the port
HBA WWN / iSCSI Name Host WWN / host iSCSI name. The name is in 16-digit hex format.

Logical Devices report

The following figure shows an example of a logical volumes report. The table following the figure describes the items in the report.

GUID-E54AA79D-D876-4B86-B42E-F58B12AAF429-low.png

Item

Description

LDEV ID

The logical volume number

LDEV Name

The logical volume name

Capacity (MB)

Capacity of the logical volume

Emulation Type

Emulation type of the logical volume

Resource Group Name

Resource group name where LDEV belongs

Resource Group ID

Resource group ID where LDEV belongs

PG

The parity group number.

  • If the number starts with "E" (for example, E1-1), the parity group contains external volumes.
  • If the number starts with "M" (for example, M1-1), the parity group contains FICON DM volumes.

    A hyphen displays for Dynamic Provisioning or Thin Image V-VOLs.

RAID Level

RAID level of the parity group where the logical volume belongs1

Drive Type/Interface/RPM

Drive type, drive control name, and revolutions-per-minute (RPM) of the drive of the parity group where the logical volume belongs.

A hyphen (-) is displayed as RPM when the drive is not HDD.1

Drive Type-Code

Type code of the drive of the parity group where the logical volume belongs1

Drive Capacity

Capacity of the drive of the parity group where the logical volume belongs.1

PG Members

List of the drive locations of the parity group where the logical volume belongs1

Allocated

Information about whether the host can access the logical volume.

For mainframe volumes and multi-platform volumes, "Y" is displayed unless the volumes are in the reserved status.

SSID

SSID of the logical volume

CVS

Information about whether the logical volume is a customized volume

OCS

Oracle checksum

Attribute

The attribute of the logical volume

Provisioning Type

Provisioning type of the logical volume

Pool Name

  • For V-VOLs of Dynamic Provisioning, the name of the pool related to the logical volume is displayed1
  • If the logical volume attribute is Pool, the name of the pool where the logical volume belongs is displayed
  • When neither of the above are displayed, the pool name is blank

Pool ID

The ID of the pool indicated by "Pool Name" A hyphen (-) displays for volumes other than pool-VOLs or V-VOLs

Current MPU

The MP unit controlling LDEVs actually.

Setting MPU

The MP unit configured to control LDEVs.

Command Device: Security

Indicates whether Security is specified as the attribute for the command device. A hyphen (-) displays when "Attribute" is not "CMDDEV".

Command Device:

User Authentication

Indicates whether User Authentication is specified as the attribute for the command device. A hyphen (-) displays when "Attribute" is not "CMDDEV".

Command Device:

Device Group Definition

Indicates whether Device Group Definition is specified as the attribute for the command device. A hyphen (-) displays when "Attribute" is not "CMDDEV".

Encryption

Indicates whether the parity group to which the LDEV belongs is encrypted.

  • For internal volumes: Enabled (encrypted) or Disabled (not encrypted)
  • For external volumes: blank

Notes:

  1. A hyphen (-) displays if the LDEV is an external volume or a FICON DM volume.

LUNs report

The following figure shows an example of an LU path definitions report. A record is created for each LU path. The table following the figure describes the items in the report.

GUID-EAF048E4-5D0B-4A21-9C54-776BECA132D0-low.png

Item

Description

Port Location

Name of the port

HBA WWN / iSCSI Name

Port WWN or name of the iSCSI (16 digits in hexadecimal)

Port Security

Name of the type of security of the port

Host Group Name / iSCSI Target Alias

Name of the host group or alias of the iSCSI target

iSCSI Target Name

Name of the iSCSI target

Host Mode

Host mode of the host group

Host Mode Option

Host mode option of the host group. Host mode options are separated by semicolons (;) when more than one option is specified.

LUN

Logical unit number

LDEV ID

Logical volume number

Emulation Type

Emulation type of the logical volume

Capacity (MB)

Capacity of the logical volume

Asymmetric Access State

Asymmetric access status:

  • Active/Optimized: Prioritized
  • Active/Non-Optimized: Lower priority

MP Units report

The following figure shows an example of an MP units report. The table following the figure describes the items in the report.

GUID-54793331-F317-47D1-8B1C-96441C9415B4-low.png

Item

Description

MP Unit ID

MP unit ID

Auto Assignment

Auto assignment attribute for the MP unit

Number of Resources (LDEV)

Number of LDEVs that the MP unit controls

Number of Resources (Journal)

Number of journals that the MP unit controls

Number of Resources (External Volume)

Number of external volumes that the MP unit controls (includes volumes for FICON DM)

Number of Resources (Total)

The total number of resources that the MP unit controls. It is the total of Number of Resources (LDEV), Number of Resources (Journal), and Number of Resources (External Volume).

MP Unit Details report

The following figure shows an example of an MP unit details report. The table following the figure describes the items in the report.

GUID-DD7D2070-57B6-4EA6-B264-D4CDF1F78F00-low.png

Item

Description

MP Unit ID

MP unit ID

Auto Assignment

Auto assignment attribute for the MP unit

Resource ID

ID of this resource that the MP unit controls

Resource Name

The name of the resource that the MP unit controls. If "Type" is LDEV, the LDEV name that is set is displayed. A hyphen (-) displays for journal volumes or external volumes.

Type

The type of the resource that the MP unit controls

Parity Groups report

The following figure shows an example of a parity groups report. The table following the figure describes the items in the report.

GUID-2041C466-B20C-448C-B918-F662E86B2B7E-low.png

Item

Description

PG

Parity group number

  • If the number starts with "E" (for example, E1-1), the parity group contains external volumes (Hitachi Universal Volume Manager User Guide).
  • If the number starts with "M" (for example, M1-1), the parity group contains volumes for FICON DM.

DKB

Name of the disk board that controls the parity group1

RAID Level

RAID level of the parity group1

Resource Group Name

Name of the resource group in which the parity group belongs

Resource Group ID

ID for the resource group in which the parity group belongs

Emulation Type

Emulation type of the parity group

Number of LDEVs (Total)

The number of the logical volumes in the parity group

Number of LDEVs (Unallocated)

The number of the logical volumes in the parity group that the host cannot access

Total LDEV Capacity (MB)

Capacity of the logical volumes in the parity group

Unallocated LDEV Capacity (MB)

Capacity of the logical volumes in the parity group that the host cannot access

Drive Type-Code

The type code of the drive in the parity group.

  • The type code of the first drive in the parity group.
  • If the parity group contains external volumes, the drive type code displays the vendor, the model, and the serial number of the storage system.
  • A hyphen (-) displays if the parity group contains volumes for FICON DM.

Drive Type/Interface/RPM

Drive type, drive control name, and revolutions-per-minute (RPM) of the drive in the parity group where the LDEV belongs1

A hyphen (-) is displayed instead of the RPM when the drive is not HDD.

Drive Capacity

Capacity of the drive in the parity group1

RAID Concatenation #0

The number indicating a parity group #0 connected to this parity group1,2

RAID Concatenation #1

The number indicating a parity group #1 connected to this parity group1,2

RAID Concatenation #2

The number indicating a parity group #1,2 connected to this parity group1,2

Encryption

Indicates whether the parity group is encrypted.

  • For internal volumes: Enabled (encrypted) or Disabled (not encrypted)
  • For external volumes: A hyphen (-) is displayed

Accelerated Compression

Accelerated compression of the parity group

  • If accelerated compression is supported, Enabled or Disabled is displayed.
  • If accelerated compression is not supported, a hyphen (-) is displayed.
Automatically manage compressed space of FMD parity group

Indicates whether to manage the compressed area of the FMD parity group automatically.

  • When accelerated compression is supported, Enabled (the area is managed automatically) or Disabled (the area is not managed automatically) is displayed
  • If accelerated compression is not supported, a hyphen (-) is displayed.

Notes:

  1. A hyphen is displayed if the parity group contains external volumes or FICON DM volumes.
  2. A hyphen is displayed if the parity group is not connected with another parity group or if the parity group contains external volumes including volumes for FICON DM.

Physical Devices report

Item

Description

LocationPDEVs name
CR#

C# and R# (2-digit hexadecimal numbers), which identify the PDEV Output in the format XX/YY, where:

  • XX: C#
  • YY: R#
PGPDEVs parity group
Emulation TypePDEVs emulation type
Drive TypePDEVs drive types
  • HHD
  • SSD
  • FMD DC2
  • SCM
  • SSD(RI)
InterfacePDEVs control name
  • SAS
  • SATA
  • NVMe
RPM

Revolutions per minute

  • 7200
  • 10000
  • 15000
A hyphen (-) displays as RPM when the drive is not HDD.
Drive Type-Code

Drive type code of the drive to which the parity group belongs

Output example: SLB5E-M19RSS;SLB5G-M19RSS

If multiple drive types are configured, they are separated by semicolon (;).
Drive Size

Drive size (inches)

  • 2.5
  • 3.5
Drive CapacityPhysical drive capacity (GB or TB)
Drive VersionDrive firmware version
DKB1Name of the DKB1 controlling the PDEV
DKB2Name of the DKB2 controlling the PDEV
Serial Number#

Serial number of this PDEV (yymm xxxxxxxx)

yy: Last 2 digits of the year

mm: month (2 characters)

xxxxxxxx: Serial number of this PDEV
RAID Level

RAID level of PDEVs

  • RAID1(2D+2D)
  • RAID5(3D+1P)
  • RAID5(7D+1P)
  • RAID6(6D+2P)
  • RAID6(14D+2P)
RAID Concatenation#0

Number of parity group (#0) being concatenated to Physical drive

Output example: 2-1, 3-1, 4-1
RAID Concatenation#1

Number of parity group (#1) being concatenated to Physical drive

Output example: 2-1, 3-1, 4-1
RAID Concatenation#2

Number of parity group (#2) being concatenated to Physical drive

Output example: 2-1, 3-1, 4-1
Resource Group NameName of the resource group to which the PDEV parity group belongs
Resource Group IDID of the resource group to which the PDEV parity group belongs (0 to 1023 decimal number)
Encryption

Encryption status of the parity group to which the PEDV belongs

  • Enabled: Encryption enabled

  • Disabled: Encryption disabled

Ports report

The following figure shows an example of part of a ports report. The actual report includes several more columns of information. The table following the figure describes the items in the report. GUID-7AF385B8-1D82-4414-8111-296528B4D352-low.png

Item

Description

CHB Name of the channel board (also called a front-end director)
Type Package type of the channel board
Port Location Name of the port on the channel board
Port Attribute Attribute of the port
iSCSI Virtual Port Mode Mode of the iSCSI virtual port
TCP Port Number Port number to use for a socket (decimal)
Internal WWN / Internal iSCSI Name WWN / iSCSI name of the port
Fabric One of the Fibre topology settings indicating the setting status of the Fabric switch1
Connection Type One of the Fibre topology settings1
  • Point to Point
  • FC-AL
IPv4 : IP Address

IPv4 address of the port

Output example: 192.168.0.100

IPv4 : Subnet Mask

IPv4 subnet mask of the port

Output example: 255.255.255.0

IPv4 : Default Gateway

IPv4 default gateway of the port

Output example: 255.255.255.0

IPv6 : Mode IPv6 settings of the port
  • Enabled
  • Disabled
IPv6 : Link Local Address IPv6 link local address of the port (16-digit hexadecimal)
IPv6 : Global Address

IPv6 global address of the port.

Output example: xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx (hexadecimal)

IPv6 : Global Address 2

IPv6 global address 2 of the port.

Output example: xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx (hexadecimal)

IPv6 : Assigned Default Gateway Assigned IPv6 default gateway
Selective ACK Selective ACK mode
  • Enabled
  • Disabled
Ethernet MTU Size (Byte) MTU settings (binary)
  • 1,500
Keep Alive Timer iSCSI keep alive timer (0 to 64,800) (sec)
VLAN : Tagging Mode Tagging mode of VLAN
  • Enabled
  • Disabled
VLAN : ID Number of VLAN set to the port (1 to 4,094)
CHAP User Name User name for the CHAP authentication
iSNS Server : Mode iSNS mode settings
  • ON
  • OFF
iSNS Server : IP Address IP address of the iSNS server (30 to 65,535)
iSNS Server : TCP Port Number Number of the TCP port used in iSNS (binary)
Address (Loop ID) Fibre port address and Loop ID of the port1
Port Security Security of the port1
  • Enabled
  • Disabled
Speed Data transfer speed of the port1
SFP Data Transfer Rate Maximum transfer rate of SFP which the mounted package supports.
  • 10G
  • 16G
  • 32G

A hyphen (-) is displayed if "Type" is "2HS10S".

T10 PI Mode

Indicates whether the T10 PI mode can be applied to the port.

  • Enabled
  • Disabled
  • Blank if the port type is a Fibre port other than 16FC2(CHB). For iSCSI ports, a hyphen (-) is displayed.
Resource Group Name Name of the resource group to which the port belongs
Resource Group ID ID for the resource group to which the port belongs (0 to 1023)
Number of Hosts The number of the hosts registered to the port1
Number of LUNs The number of the LU paths defined to the port1
Number of LDEVs The number of the logical volumes that can be accessed through the port1
Number of PGs The number of the parity groups having the logical volumes that can be accessed through the port1
Number of DKBs The number of the disk boards controlling the parity group that contains the logical volumes that can be accessed through the port1

Notes:

  1. For ports in a mainframe system, a hyphen is displayed.

Power Consumption report

The following figure shows an example of a power consumption report. A record is created every two hours for each power consumption and temperature monitoring data. The table following the figure describes the items in the report.

No records are created if the DKC is turned off. If the system is in maintenance mode or the SVP is rebooted, up to two hours of records could be lost.

If a failure occurs in the storage system, the correct information might not be output.

A hyphen(-) is displayed if the power and temperature information cannot be acquired due to a unit or network failure.

GUID-D8C3B3A6-5190-406D-95CD-D98D2088E368-low.png

Item

Description

Power Consumption Average (W)

Average of the power consumption

Power Consumption Maximum (W)

Maximum of the power consumption

Power Consumption Minimum (W)

Minimum of the power consumption

TEMP:HSNBX0-HSNPANEL0 Average (degrees C)Average temperature of HSNBX0:HSNPANEL0
TEMP:HSNBX0-HSNPANEL0 Maximum (degrees C)Maximum temperature of HSNBX0:HSNPANEL0
TEMP:HSNBX0-HSNPANEL0 Minimum (degrees C)Minimum temperature of HSNBX0:HSNPANEL0
TEMP:HSNBX1-HSNPANEL1 Average (degrees C)Average temperature of HSNBX1:HSNPANEL1
TEMP:HSNBX1-HSNPANEL1 Maximum (degrees C)Maximum temperature of HSNBX1:HSNPANEL1
TEMP:HSNBX1-HSNPANEL1 Minimum (degrees C)Minimum temperature of HSNBX1:HSNPANEL1

TEMP:DKC0-Cluster1 Average (degrees C)

Average temperature of DKC0:CL1

TEMP:DKC0-Cluster1 Maximum (degrees C)

Maximum temperature of DKC0:CL1

TEMP:DKC0-Cluster1 Minimum (degrees C)

Minimum temperature of DKC0:CL1

TEMP:DKC0-Cluster2 Average (degrees C)

Average temperature of DKC0:CL2

TEMP:DKC0-Cluster2 Maximum (degrees C)

Maximum temperature of DKC0:CL2

TEMP:DKC0-Cluster2 Minimum (degrees C)

Minimum temperature of DKC0:CL2

TEMP:DKC1-Cluster1 Average (degrees C)

Average temperature of DKC1:CL1

TEMP:DKC1-Cluster1 Maximum (degrees C)

Maximum temperature of DKC1:CL1

TEMP:DKC1-Cluster1 Minimum (degrees C)

Minimum temperature of DKC1:CL1

TEMP:DKC1-Cluster2 Average (degrees C)

Average temperature of DKC1:CL2

TEMP:DKC1-Cluster2 Maximum (degrees C)

Maximum temperature of DKC1:CL2

TEMP:DKC1-Cluster2 Minimum (degrees C)

Minimum temperature of DKC1:CL2

Power Consumption report for DKU00

Item

Description

TEMP:DKU00-DBS000-1 Average (Temperature in degrees C) ,

TEMP:DKU00-DBS000-1 Maximum (Temperature in degrees C) ,

TEMP:DKU00-DB000-1 Minimum (Temperature in degrees C) ,

… ,TEMP:DKU00-DB007-2 Average (Temperature in degrees C) ,

TEMP:DKU00-DB-2 Maximum (Temperature in degrees C) ,

TEMP:DKU00-DB-2 Minimum (Temperature in degrees C)

Average temperature, maximum temperature, and minimum temperature of the drive box (DB) for the two-hour period. Outputs in the following format:

TEMP:DKUXX-DBYYY-DBPSYYY-A Average, Maximum, or Minimum (Temperature in degrees Celsius)

  • DKUXX: DKU location number (decimal)
  • DBYYY or DBYYY&ZZZ: DB location number

    The display format of DB location numbers differs depending on the type of DB.

    • DBYYY: DBL location number (decimal)
    • DBYYY&ZZZ: Location number of DBS2, DBF3, or DBN (decimal)

      Two DB numbers are written together, and then displayed as one DB location.

  • DBPSYYY-A: DBPS location number
    • YYY: DB location number (decimal)
    • A: DBPS number (1, 2)

Spare Drives report

The following figure shows an example of a spare drives report. The table following the figure describes the items in the report.

GUID-EA7FDAAD-60BE-4704-8701-A6914C2F8200-low.png

Item

Description

Drive Capacity

Capacity of the spare drive

Drive Type-Code

Type code of the spare drive

Location

Location of the spare drive

SSD Endurance report

The following figure shows an example of an SSD/SCM endurance report. The table following the figure describes the items in the report.

GUID-4E2A04FD-DF7B-47E3-8D07-4932A19E0A0C-low.png

Item

Description

Drive Type-Code

Type code of the drive

Drive Capacity

Capacity of the drive

Location

Location of the drive

Used Endurance Indicator (%)

The used endurance of SSD life (0 to 100)

The value of this indicator increases due to drive operation associated with internal processing of the storage system, and the host I/O. Even when no data is copied due to a drive failure, the value of this indicator increases because the spare drive also performs internal processing.

Storage System Summary report

The following illustration shows an example of part of a report of a summary of the storage system. The actual report includes several more rows of information. The table following the illustration describes the items in the report.

GUID-A2D3647F-A5F4-4047-B102-05909DE8CD12-low.png
Item Description
Storage System Type Type of the storage system.
Serial NumberSerial number of the storage system.
IP Address IP address of the SVP.
Software Versions Version of the following programs.
  • DKCMAIN
  • HTP
  • ISCF
  • FCBK
  • ISW
  • DKB
  • DKBN
  • SVP
  • CBA
  • SSVP
  • GUM
  • FCDG
  • ROMBOOT
  • RAMBOOT
  • Expander
  • NSW
  • CONFIG
  • CFM
  • HDD
  • HDD (SVP)
  • Printout Tool
  • EDKBN
Number of CUs The number of control units in the storage system
Shared Memory Size (GB) Shared memory capacity

Includes the cache management information (directory)

Cache Size (GB) Cache capacity
Number of DKBs The number of disk boards on the module
System Options List of the system options specified for the storage system
Drive Capacity (TB) Total capacity of drives in the storage system except for external volumes
Spare Drive Capacity (TB) Total capacity of the spare drives in the storage system
Free Drive Capacity(TB) Total capacity of the free drives in the storage system
OPEN Volume Capacity (GB) 1 List of the capacity of the open volumes
M/F Volume Capacity (GB) 1 The list of the capacity of the mainframe volumes and multi-platform volumes
Number of LDEVs1 List of the numbers of the volumes in the following status.
  • allocated
  • unallocated
  • reserved
  • free

The list for open-systems and the list for mainframe-systems are separate.

Notes:
  1. You cannot sort this list.