You can monitor alerts and events in various ways including email, the management interfaces, as well as using the Windows Event Log.

Monitoring SIMs alerts in Device Manager - Storage Navigator

The Device Manager - Storage Navigator main window opens an icon indicating whether service information messages (SIMs) occurred in the storage system.

  1. In the Device Manager - Storage Navigator main window, click Alert. The Alerts window opens.

    GUID-E93E58B6-9F19-4B86-813F-E6AC5FE846AF-low.png
  2. To check the details of each alert, select and right-click one row, and then click Detail in the pop-up menu. The detail dialog box opens.

  3. If the following SIM reference codes appear (see table below), you must resolve the error.

    Reference code

    Program product

    601xxx*

    Thin Image

    602xxx*

    602ffe

    620xxx*

    Dynamic Provisioning

    Dynamic Provisioning for Mainframe

    621xxx*

    622xxx*

    624000

    Thin Image

    Dynamic Provisioning

    Dynamic Provisioning for Mainframe

    625000

    Dynamic Provisioning

    Dynamic Provisioning for Mainframe

    626xxx*

    641xxx*

    Dynamic Tiering

    Dynamic Tiering for Mainframe

    *xxx indicates a pool number. Pool numbers are decimal and displayed on the Alert Properties window.

    For details on how to resolve the error, see the Hitachi Thin Image User Guide, the Provisioning Guide for Open Systems, or the Provisioning Guide for Mainframe Systems.

Events that do not affect the operation of the storage system

Occurrence of the following events does not affect the operation of the storage system:

NoteThese events can be ignored.
Event Timing of occurrence of event

Log type: Application

Source: Application Error

Event ID: 1000

Level: Error

Application on which an error occurs:

DkcMan.exe

Module in which an error occurs:

ntdll.dll orjvm.dll

Exception code: 0xc0000005

This event might occur at the following timing:
  • When the storage management software is updated
  • When the SVP is shut down or rebooted

Log type: Application

Source: Application Error

Event ID: 1000

Level: Error

Application on which an error occurs:

KickJava.exe

Module in which an error occurs:

SVPCMN32.dll

Exception code: 0xc0000005

This event might occur when the service of the storage system is stopped.

Log type: Application

Source: Application Error

Event ID: 1000

Level: Error

Application on which an error occurs:

MpcL7Comm.exe

Module in which an error occurs:

MpcL7Mem.dll

Exception code: 0xc0000005

This event might occur at the following timing:
  • When the services on the storage system stop
  • When the storage management software is updated
  • When the SVP is shut down or rebooted