Hardware overview

 

The storage system consists of a controller chassis using a multi-node architecture that deploys a copper or optical link, as well as the basic rack layouts similar to previous model.

Hardware components

 

The storage system consists of a controller chassis comprising controller boards, drive chassis in which drives are installed, and a node interconnect switch consisting of interconnect switches and an SVP. The storage system also supports cache memory (DIMM) and cache flash memory (CFM).

The controller chassis, drive chassis, and node interconnect switch are installed in a 19-inch Hitachi Universal rack.

Controller chassis

 

The controller chassis consists of a controller board, front-end module, back-end module, fabric-acceleration module, power supply, and cache flash memory. Controllers are storage system components that cache and manage data, and provide hosts with a coherent, virtualized view of the system. A controller chassis contains two nodes with a 4U controller each, making the chassis 8U high. A storage system can contain 2 to 6 nodes, depending on the storage system model.

GUID-BA53A3CE-F0AA-4517-A7EB-74B46958978D-low.png
Number Item Description
1 POWER LED

Green: Storage system is powered on.

Amber: Storage system is receiving power.

2 READY LED

Green: Normal operation.

3 WARNING LED

Off: Normal operation.

Amber: Component requires maintenance.

Blink: Failure requires maintenance.

Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100.

LED might turn off during user maintenance.

4 ALARM LED

Off: Normal operation.

Red: Processor failure (system might be down). For assistance, contact customer support: https://support.hitachivantara.com/en_us/contact-us.html.

5 POWER ON/OFF (main switch)

Powers the storage system.

GUID-0D62DA7D-0B28-4A21-B22C-14CFD7E37ABB-low.png

Number Item Description
1 Controllers

Controller 1 (bottom) and Controller 2 (top).

2 Backup module N/A
3 BACKUP LED

Green: Power restoration in progress following power outage.

Fast blink green: Restoring.

Slow blink green: Restoring, or sequential shutdown in progress.

4 Cache flash memory N/A
5 ALM LED (for cache flash memory)

Red: Cache flash memory can be removed.

6

CTL ALM LED

Red: Controller can be removed.

Blink red: Failure with the power supply unit of the controller.

Amber: LAN reset switch was pressed.

7

LAN-RST switch

Use only when instructed by customer support.

8

STATUS LED (for BKMF)

Green: Charging of the battery in the backup module is complete.

Red: Backup module can be removed.

Blink red one time: Main battery failure.

Blink red two times: Backup battery failure.

Blink red three times: Both batteries failed or preventive maintenance replacement of batteries can run.

Off: Battery is not mounted, battery-mounting failure occurred, or firmware is being upgraded. Off is normal status for configurations without batteries.

9

POWER ON/OFF (main switch)

Powers the storage system.
10

POWER, READY, WARNING, and ALARM LEDs

Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100.

GUID-E49E2948-D32A-4570-8FCA-55F0888CFF2C-low.png

 

Number Item
1 Power supply unit
2 Front-end director
3 LAN blade
4 Fabric-Acceleration Module
5 Back-end director
GUID-BFCDF0DF-5CE1-4382-8964-B03F690BA79C-low.png
Number Item Description
1 ALM / RDY LED Red: Power supply unit can be replaced.
2 RDY LED Green: Normal operation.

Controller board

 
GUID-7D835195-EA39-4366-8592-A0819B24C599-low.png
Number Item Description
1 STATUS

LED Off: Battery is uninstalled, installed improperly or BKMF firmware is replaced (in case of a configuration with no battery installed, the LEDs for BKMF-10 and BKMF-20 go out).

Green On: Battery is fully charged.

Green Blinking: Battery is charged or discharged.

Red On: BKMF has an error.

Red Blinking: BKMF can be removed. A failure occurred in the battery or preventive maintenance replacement of the batteries is possible.

2 LAN-RST

This is a switch for GUM reset.

If GUM reboot fails, reset GUM forcibly from the hardware.

3 CTL ALM

Red On: The controller board is ready to be removed (when the maintenance work requiring insertion and removal of the controller board is performed). A failure is detected in the controller board (when the maintenance work mentioned above is not performed).

Red Blinking: A failure is detected in the controller board, cache memory, or cache flash memory (CFM).

Amber On: Indicates that the LAN RESET switch is pressed.
4 BACKUP STS

Green On : Indicates that power outage has occurred or power restoration is in progress after power outage.

  • Fast blinking (On and off are repeated at 0.1-second intervals.): The data is being restored.
  • Slow blinking (On and off are repeated at 0.5-second intervals.): A planned power off is being executed or the data is being stored.
5 ALARM Red On: Cache Flash Memories are removable.
GUID-0D0CE03D-3A6E-4F57-A398-D54B2DA0DCD7-low.png
Number Item Description
1 ACT/LINK LED Amber: Link status/data transfer status.
2 SPEED LED

On: Link speed = 1 Gbps.

Off: Link speed = 10 Mbps/100 Mbps.

3

LAN ALARM LED

Red: The removal of the LAN Board is possible.

10-Gbps iSCSI board(optical)

 
GUID-D72C85AE-D8E6-4878-88C4-4C568F348582-low.png
Number Item Description
1 ISCSI connectors Connect to Ethernet cables.
2 STATUS LED

Green: Front end module is in the power-on state.

Red: Front end module has an error.

3 PORT LED

Red: SFP has an error.

Blue: Normal link status.

Blink blue: Front end module is in communication status.

Port assignments for 10-Gbps iSCSI board
 
Number Port 1 Port 2
CHB-01A 1A 3A
CHB-01B 1C 3C
CHB-01E 1E 3E
CHB-01F 1G 3G
CHB-02A 1B 3B
CHB-02B 1D 3D
CHB-02E 1F 3F
CHB-02F 1H 3H
CHB-11A 2A 4A
CHB-11B 2C 4C
CHB-11E 2E 4E
CHB-11F 2G 4G
CHB-12A 2B 4B
CHB-12B 2D 4D
CHB-12E 2F 4F
CHB-12F 2H 4H

16-Gbps or 32-Gbps Fibre Channel (4-port) board

 

GUID-25255ED9-53B0-4812-AFE3-7BCF68D1AE5F-low.png

Table 1: 16-Gbps, 32-Gbps Fibre Channel
Number Item Description
1 Fibre Channel connectors Connect to Fibre Channel cables.
2

STATUS LED

Green: Front end module is in the power-on state.

Red: Front end module has an error.

3 PORT LED

Red: Small form-factor pluggable can be removed.

Blue: Normal link status at 16-Gbps (16-Gbps).

Blue: Normal link status at 32-Gbps (32-Gbps).

Green: Normal link status at 4-Gbps or 8-Gbps (16-Gbps).

Green: Normal link status at 8-Gbps or 16-Gbps (32-Gbps).

Port assignments for 16-Gbps or 32-Gbps Fibre Channel board
 
Number Port 1 Port 2 Port 3 Port 4
CHB-01A 1A 3A 5A 7A
CHB-01B 1C 3C 5C 7C
CHB-01E 1E 3E 5E 7E
CHB-01F 1G 3G 5G 7G
CHB-02A 1B 3B 5B 7B
CHB-02B 1D 3D 5D 7D
CHB-02E 1F 3F 5F 7F
CHB-02F 1H 3H 5H 7H
CHB-11A 2A 4A 6A 8A
CHB-11B 2C 4C 6C 8C
CHB-11E 2E 4E 6E 8E
CHB-11F 2G 4G 6G 8G
CHB-12A 2B 4B 6B 8B
CHB-12B 2D 4D 6D 8D
CHB-12E 2F 4F 6F 8F
CHB-12F 2H 4H 6H 8H

Back-end module

 
GUID-81D9B5C2-EBC1-441E-9410-14CA1D200693-low.png
Number Item Description
1 PATH 0 connector Connect to a drive tray.
2 PATH 1 connector Connects to a drive tray.
3 STATUS LED

Green: Back end module is in the power-on state.

Red: Back end module can be removed safely.

4 PORT LED Blue: Link status is normal.
 
Port assignments for the back-end module
 
Number Port 0 Port 1
DKB-01D 01D-0 01D-1
DKB-01H 01H-0 01H-1
DKB-02D 02D-0 02D-1
DKB-02H 02H-0 02H-1
DKB-11D 11D-0 11D-1
DKB-11H 11H-0 11H-1
DKB-12D 12D-0 12D-1
DKB-12H 12H-0 12H-1

Fabric-acceleration module

 
GUID-5EDCF9A4-36B7-47A5-9A0A-E69E16F25D25-low.png
Number Item Description
1 Ports  
2 TBD

Blinking (Yellow): The target port is incorrectly connected.

On (Yellow): Any of the ports is incorrectly connected.

Green: Not used.

3 PORT (LINK/LOCATE)

On (Blue): Linked state.

Blinking (Red): A failure has occurred. The port is blocked.

On (Red): The cable can be removed.

Off: Link down state.

4 STATUS

On (Green): The module is powered on.

On (Red): The module can be removed.

Off: The module is powered off.

Port assignments for fabric-acceleration module
 
Fabric-Acceleration Module Number Port 0 Port 1
HIE-01C HIE-01C-0 HIE-01C-1
HIE-01G HIE-01G-0 HIE-01G-1
HIE-02C HIE-02C-0 HIE-02C-1
HIE-02G HIE-02G-0 HIE-02G-1
HIE-11C HIE-11C-0 HIE-11C-1
HIE-11G HIE-11G-0 HIE-11G-1
HIE-12C HIE-12C-0 HIE-12C-1
HIE-12G HIE-12G-0 HIE-12G-1

Drive box

 

Drive boxes are compact storage enclosures that can hold a large numbers of disk drives in a small rack space (EIA-standard rack units).

GUID-17E60A53-28EE-4EE6-A93C-1F6900B94AB5-low.png

Number Item Description
1 POWER LED Green: Storage system is powered on.
2 READY LED

Green: Normal operation.

3 LOCATE LED Amber: Failure requires maintenance.

The LED can be lit/turned off by the Maintenance Utility.

The storage system supports the following drives:

Drive Box for SBX The media chassis for SBX contains four 2U drive boxes in which 2.5-inch disk drives and the 2.5-inch flash drives are installed. Each drive box consists of two enclosures and two power supplies with a built-in cooling fan.

The SBX holds 96 2.5-inch small form factor SAS/SSD drives or NVMe drives

GUID-CEF56240-66F9-4FC4-831B-CE6641E4F39E-low.png
Number Item Description
1 ALM

Red: Indicates that the removal of the HDD/SSD is possible when the storage system is powered on.

2 ACT

Green: Indicates that the HDD/SSD is powered on.

Blinking Green: Indicates that the HDD/SSD is active.

The blink speed may differ between HDDs and SSDs; however, this does not indicate a disk error or failure.

3 POWER Green: Indicates that the power supply is supplied to the storage system.
4 READY Green: Indicates that the ENC is operating normally.
5 LOCATE

Amber: Indicates the location of the chassis that detects a failure.

The LED can be lit/turned off by Maintenance Utility.

GUID-C1E0ED0B-E031-4DA7-B122-64AE12127984-low.png
Number Item Description
1 PATH (IN side) Green: Indicates that the IN side is linked up.
2 PATH (OUT side) Green: Indicates that the OUT side is linked up.
3 PATH (IN side) Green: Indicates that the IN side is linked up.
4 PATH (OUT side) Green: Indicates that the OUT side is linked up.
5 POWER Green: Indicates that the power is supplied to the ENC.
6 LOCATE

Amber: A LED to specify the chassis location on the rear of the chassis.

The LED can be lit/turned off by Maintenance Utility.

7 ALARM (REPLACE) Red: Lights up when replacement of the ENC is possible.
8 Consol port Not in use
GUID-08DF12AD-F4E4-46CF-A76E-B9F32E7E16FB-low.png
Number Item Description
1 RDY2

Green: Normal operation

Off: Erroneous operation or out of operation

2 RDY1

Green: Normal operation

Off: Erroneous operation or out of operation

3 AC IN Green: Indicates that AC input is normal.
4 ALM (REPLACE) Red: Indicates when the power supply can be replaced.
Drive Box for UBX

The media chassis for UBX contains eight 2U drive boxes in which 3.5-inch disk drives are installed. Each drive box consists of two ENCs and two power supplies with a built-in cooling fan.

The UBX holds 96 3.5-inch large form factor SAS/SSD drives

GUID-C2E36B57-0F10-4BD6-B59B-53658B57CEE7-low.png

Number Item Description
1 POWER Green: Indicates that the power supply is supplied to the storage system.
2 READY Green: Indicates that the ENC is operating normally.
3 LOCATE

Amber: Indicates the location of the chassis that detects a failure.

The LED can be lit/turned off by Maintenance Utility.

4 ACT

Green: Indicates that the HDD/SSD is powered on.

Blinking Green: Indicates that the HDD/SSD is active.

The blink speed may differ between HDDs and SSDs; however, this does not indicate a disk error or failure.

5 ALM

Red: Indicates that the removal of the HDD/SSD is possible when the storage system is powered on.

GUID-98E318E6-9194-465A-98A4-D464D1D39FDB-low.png
Number Item Description
1 POWER Green: Indicates that the power is supplied to the ENC.
2 LOCATE

Amber: A LED to specify the chassis location on the rear of the chassis.

The LED can be lit/turned off by Maintenance Utility.

3 ALARM (REPLACE) Red: Lights up when replacement of the ENC is possible.
4 PATH (IN side) Green: Indicates that the IN side is linked up.
5 PATH (OUT side) Green: Indicates that the OUT side is linked up.
6 Consol port Not in use
GUID-08DF12AD-F4E4-46CF-A76E-B9F32E7E16FB-low.png
Number Item Description
1 RDY2

Green: Normal operation

Off: Erroneous operation or out of operation

2 RDY1

Green: Normal operation

Off: Erroneous operation or out of operation

3 AC IN Green: Indicates that AC input is normal.
4 ALM (REPLACE) Red: Indicates when the power supply can be replaced.
Drive Box for NBX

The media chassis for NBX contains four 2U drive boxes in which 2.5-inch NVMe drives are installed. Each drive box consists of two ENCs and two power supplies with a built-in cooling fan.

The NBX holds 98 Hitachi Flash (FMD) drives

GUID-CEF56240-66F9-4FC4-831B-CE6641E4F39E-low.png
Number Item Description
1 ALM

Red: Indicates that the removal of the HDD/SSD is possible when the storage system is powered on.

2 ACT

Green: Indicates that the HDD/SSD is powered on.

Blinking Green: Indicates that the HDD/SSD is active.

The blink speed may differ between HDDs and SSDs; however, this does not indicate a disk error or failure.

3 POWER Green: Indicates that the power is supplied to the ENC.
4 READY Green: Indicates that the ENC is operating normally.
5 LOCATE

Amber: A LED to specify the chassis location on the rear of the chassis.

The LED can be lit/turned off by Maintenance Utility.

GUID-3E83FA9B-6629-4B7B-9D5C-449F5F70CBDB-low.png
Number Item Description
1 POWER Green: Indicates that the power is supplied to the ENC.
2 LOCATE

Amber: A LED to specify the chassis location on the rear of the chassis.

The LED can be lit/turned off by Maintenance Utility.

3 ALARM

Red: Indicates that the removal of the HDD/SSD is possible when the storage system is powered on.

4 LINK Blue: Indicates that PCIe between DKBN and ENC is linked up.
GUID-08DF12AD-F4E4-46CF-A76E-B9F32E7E16FB-low.png
Number Item Description
1 RDY2

Green: Normal operation

Off: Erroneous operation or out of operation

2 RDY1

Green: Normal operation

Off: Erroneous operation or out of operation

3 AC IN Green: Indicates that AC input is normal.
4 ALM (REPLACE) Red: Indicates when the power supply can be replaced.
Drive Box for FBX

The media chassis for FBX contains four 2U drive boxes in which FMD drives are installed. Each drive box consists of two ENCs and two power supplies with a built-in cooling fan.

The FBX holds 48 Hitachi Flash (FMD) drives

GUID-33FD4B4D-7747-4D04-9AA7-3F4E9E18CC74-low.png
Number Item Description
1 ACT

Green: Indicates FMD status.

Blinking Green: Indicates that the FMD is active.

The blink speed may differ between FMD LEDs; however, this does not indicate a disk error or failure.

2 ALM

Red: Indicates that the removal of the FMD is possible when the storage system is powered on.

3 POWER Green: Indicates that the power supply is supplied to the storage system.
4 READY Green: Indicates that the ENC is operating normally.
5 LOCATE

Amber: Indicates the location of the chassis that detects a failure.

The LED can be lit/turned off by Maintenance Utility.

GUID-049C245E-2A3C-4F53-A9AE-E9F764FAC993-low.png
Number Item Description
1 PATH (IN side) Green: Indicates that the IN side is linked up.
2 PATH (OUT side) Green: Indicates that the OUT side is linked up.
3 POWER Green: Indicates that the power is supplied to the ENC.
4 LOCATE

Amber: A LED to specify the chassis location on the rear of the chassis.

The LED can be lit/turned off by Maintenance Utility.

5 ALARM (REPLACE) Red: Lights up when replacement of the ENC is possible.
GUID-FEA8BC72-35CB-4F60-B8C4-AD6983FD8F9A-low.png
Number Item Description
1 RDY 1

Green: Normal operation

Off: Erroneous operation or out of operation

2 RDY 2

Green: Normal operation

Off: Erroneous operation or out of operation

3 ALM REPLACE Red: Indicates when the power supply can be replaced.

Disk drive and flash drive

 

The disk drives and flash drives supported by the storage system are shown below.

Group Interface Size (inch) Transfer rate (Gbps) Revolution Speed (min-1) or Flash Memory Technology Capacity
HDD NL-SAS 3.5 12 7,200
  • 10TB
  • 14TB
HDD SAS 2.5 12 10,000
  • 2.4TB
SSD SAS 2.5 12 MLC/TLC
  • 960GB
  • 1.9TB
  • 3.8TB
  • 7.6TB
  • 15.3TB
  • 30TB
SSD NVMe 2.5 8 TLC
  • 1.9TB
  • 3.8TB
  • 7.6TB
  • 15.3TB

Node interconnect switch

 

The node interconnect switch is a 1U switch chassis that contains interconnect and management components. A node interconnect switch consists of two interconnect switches, a service processor (SVP), an ethernet switch (SSVP), an operation panel, and two power supplies with a built-in cooling fan. The primary and secondary node interconnect switches must be installed in the storage system. For the secondary node interconnect switch, SVP and SSVP are optional.

GUID-0FF2C73A-43E5-45FE-A385-ECC6C3E39F49-low.png

Identifier Name Description
1 Operation Panel The operation panel show system status with LED, and controls power on and off of the storage system.
2 Backup Service Processor A redundant SVP in case main SVP fails.
3 Main Service Processor The SVP provides status information about the storage system.
4 Ethernet Switch (SSVP) The SSVP is a LAN hub that connects the SVP to each controller chassis, optional SSVP, and maintenance PC.
GUID-05C86AE5-DD54-4CA9-81E6-83FA6387FB71-low.png
Number Item Description
1 REMOTE MAINTENANCE ENABLE/DISABLE

Used to enable or disable the remote maintenance of the storage system.

ENABLE : Remote maintenance is allowed.

DISABLE : Remote maintenance is not allowed.

2 PS SW ENABLE

Move this switch to the ENABLE position to allow the PS ON/PS OFF switch to power on or power off the storage system..

3 PS ON/PS OFF

To power on or off the storage system, move this switch while holding the PS SW ENABLE switch in the ENABLE position.

4 LOCATE

Amber: The node interconnect switch needs maintenance.

Off: Normal condition.

5 READY

Green: I/O operation on the channel interface is possible.

Off: Not ready.

6 ALARM

Red: The storage system is down, or an MP block occurred.

Off: Not in the alarm status.

7 MESSAGE

Amber: The storage system is down, or an MP block occurred. The storage system detected a failure, and a SIM related to the failure was reported to the SVP. The LED continues to light until the maintenance personnel changes the SIM attribute to 'complete'.

One blinking amber: SVP became faulty in a single SVP configuration.

Two blinking amber: SVPs became faulty in a dual SVP configuration. If one of the two SVPs becomes faulty in a dual SVP configuration, this LED does not blink.

8 REMOTE MAINTENANCE PROCESSING

Amber: Remote maintenance (ASSIST) is being operated.

GUID-AD387755-B8BC-4D36-A910-CE028D3EBE30-low.png
Number Item Description
1 REMOTE MAINTENANCE ENABLE/DISABLE

Used to enable or disable the remote maintenance of the storage system.

ENABLE : Remote maintenance is allowed.

DISABLE : Remote maintenance is not allowed.

2 PS SW ENABLE

Move this switch to the ENABLE position to allow the PS ON/PS OFF switch to power on or power off the storage system..

3 PS ON/PS OFF

To power on or off the storage system, move this switch while holding the PS SW ENABLE switch in the ENABLE position.

4 LOCATE

Amber: The node interconnect switch needs maintenance.

Off: Normal condition.

5 READY

Green: I/O operation on the channel interface is possible.

Off: Not ready.

6 ALARM

Red: The storage system is down, or an MP block occurred.

Off: Not in the alarm status.

7 MESSAGE

Amber: The storage system is down, or an MP block occurred. The storage system detected a failure, and a SIM related to the failure was reported to the SVP. The LED continues to light until the maintenance personnel changes the SIM attribute to 'complete'.

One blinking amber: SVP became faulty in a single SVP configuration.

Two blinking amber: SVPs became faulty in a dual SVP configuration. If one of the two SVPs becomes faulty in a dual SVP configuration, this LED does not blink.

8 REMOTE MAINTENANCE PROCESSING

Amber: Remote maintenance (ASSIST) is being operated.

9 BS ON

Amber: The auxiliary power supply in the storage system is powered on.

10 PS ON

Green: The storage system is powered on.

Interconnect switch

 
GUID-63913C0E-6C5A-4B5B-A0D3-B55262971E9C-low.png

 

Number Item Description
1 PORT

Red: The cable needs maintenance

Blinking Red: Error state (not linked state)

Blinking Amber/Green): Error state (linked state)

Green: Normal state (linked state)

Off: Link down state.

2 ALARM On: An error has occurred.
3 POWER On: The ISW is powered on.

Service Processor

 

The SVP monitors storage system operations by collecting statistics and reporting this information to the Hitachi Remote Ops monitoring system.

If an optional second SVP is installed, the primary SVP is the active unit while the secondary SVP acts as a hot standby. If the primary SVP fails, the hot standby SVP takes over within three minutes. In this way, the dual-SVP configuration eliminates single points of failure with the SVP. GUID-8550D973-1E3F-447A-A1CF-909BBC7D1701-low.png
Number Item Description
1 SVP PS ON/OFF

Used to power on or off the SVP power supply.

Holding down this switch shuts down the power supply.

2 SVP POWER Green: The SVP power supply is powered on.
3 SVP DCIN Green: The SVP is receiving DC power.
4 SVP HDD Green: The HDD in the SVP is being accessed.
5 SVP SHUT DOWN Red: The SVP can be removed when the storage system is powered on.

The table lists the technical specifications of the service processor.

Component

Specifications

Operating System

Windows 10 IoT Enterprise 2016 LTSB

CPU

Intel® Pentium® N4200 2.5GHz Processor

Internal Memory

8GB

Disk drive

256GB (SATA3.0 mSATA)

LAN

On-Board 10Base-T/ 100Base-TX /1000Base-T x 2 Port

HUB

10Base-T/ 100Base-TX /1000Base-T x 10 Port

USB

Version 2.0/3.0 x 4 ports

*Because the SVP has no monitor or keyboard, a maintenance PC must be connected to the SVP to view the information collected by the SVP.

Ethernet Switch(SSVP)

 

GUID-B63CD9E0-9020-49CF-AFE1-9AE4402AFE9D-low.png

Number Item Description
1 SSVP RESET Used to reset the hardware of the SSVP.
2 SVP RAS SET

Used to set the RAS function of the SVP.

Use this switch together with the SVP RAS switches #2, #3, and #4.

3 SVP RAS

#1 : The SVP PS ON/OFF INH switch to suppress rebooting the SVP.

#2, #3, and #4 : Used with the SVP RAS SET switch to set each function of the SVP. See table below for functions.

4 SSVP REP

The SSVP is ready to be replaced for maintenance.

This LED is lit by SVP control.

5 SVP STATUS This LED is turned on or off by program control via a RAS driver.
Setting Operation #2 #3 #4 SVP RAS SET switch

SVP IP ADDRESS DISPLAY

First time ON OFF OFF Press down
HUB RESET First time ON OFF ON Press down

Disabling the setting, or cancelling the first operation

First time ON ON ON Press down
Second time OFF OFF OFF Press down

SVP PASSWORD/IP ADDRESS INITIALIZATION

First time ON ON ON Press down
Second time OFF OFF ON Press down

Interconnect switch power supply

 

GUID-122FD001-9F96-40B3-8F4D-9E39232D2231-low.png

Number Item Description
1 PORT Blue: AC input is normal.
2 ALM/RDY

Red : The ISWPS is ready to be replaced.

Green : The ISWPS is operating normally.

LED locations for high availability node

 

GUID-BA53A3CE-F0AA-4517-A7EB-74B46958978D-low.png

GUID-66A7F722-A2C0-4512-A2FA-4B089C3C4084-low.png

 

Number Item Description
1 POWER LED

Green: Storage system is powered on.

Amber: Storage system is receiving power.

2 READY LED

Green: Normal operation.

3 WARNING LED

Off: Normal operation.

Amber: Component requires maintenance.

Blink: Failure requires maintenance.

Note: When System Option Mode 1097 is set to ON, the WARNING LED does not blink, even if the following failure service information messages (SIM) are issued: 452xxx, 462xxx, 3077xx, 4100xx, and 410100.

LED might turn off during user maintenance.

4 ALARM LED

Off: Normal operation.

Red: Processor failure (system might be down). For assistance, contact customer support: https://support.hitachivantara.com/en_us/contact-us.html.

5 POWER ON/OFF (main switch)

Powers the storage system.