Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

SIM codes

You can use the failure trap reference to identify trap reference codes (SIM codes) to see what section it affects and the alert levels.

Failure trap reference codes

The following table lists and describes the failure trap reference codes.

For details on alert levels, see the System Administrator Guide.

Trap reference code

Section

Description

Alert level

Host report1

SIM 22

SIM 23

SIM 13

18

00

00

AuditLog lost

DKC environment

MODERATE

Yes

21

20

xx

Channel port blocking

Processor

MODERATE

Yes

21

60

xx

HIE blocking

Cache

MODERATE

Yes

21

61

xx

ISW blocking

Cache

MODERATE

Yes

21

62

xx

X path blocking

Cache

MODERATE

Yes

21

63

xx

HIE warning

Cache

MODERATE

Yes

21

64

xx

X path warning

Cache

MODERATE

Yes

21

80

xx

Logical path(s) on the remote copy connections was logically blocked (Due to an error condition)

Processor

MODERATE

Yes2

21

81

xx

RIO PATH AUTOMATICALLY RECOVERED

Processor

SERVICE

Yes

21

90

xx

AL_PA VALUE CONFLICT

Processor

SERVICE

No

21

93

xx

LINK FAILURE

Processor

SERIOUS

Yes

21

94

xx

LINK FAILURE2

Processor

SERIOUS

Yes

21

a3

xx

HTP blocking

Processor

MODERATE

Yes

21

a4

xx

Fiber Cable Failure

Processor

SERVICE

No

21

a8

xx

SFP wrong type

Processor

MODERATE

No

21

aa

xx

SFP TxFault

Processor

MODERATE

No

21

bx

xx

HTP hard error

Processor

MODERATE

Yes

21

d0

xx

External storage system connection path blocking

Processor

MODERATE

Yes

21

d1

xx

External storage system connection path restore

Processor

SERVICE

No

21

d2

xx

Threshold over by external storage system connection path response time-out

Processor

SERVICE

Yes

21

d4

xx

Blocking the Data Migration path

Processor

MODERATE

No

21

d5

xx

Data Migration Path Recovery

Processor

SERVICE

No

30

70

xx

CHK1A THRESHOLD OVER

Processor

SERVICE

No

30

71

xx

CHK1B THRESHOLD OVER

Processor

SERVICE

No

30

72

xx

CHK3 THRESHOLD OVER

Processor

SERVICE

No

30

73

xx

PROCESSOR BLOCKING

Processor

MODERATE

Yes

30

75

xx

FM ERROR

Processor

MODERATE

Yes

30

76

xx

Incorrect SUM value of FM

Processor

SERVICE

No

30

77

xx

PROCESSOR MEMORY TEMPORARY ERROR

Processor

SERVICE

No

30

80

xx

WCHK1 dump

Processor

MODERATE

No

30

a1

00

DKC Blockade

Processor

ACUTE

Yes

38

8f

00

P/S OFF IMPOSSIBLE

PS(DKC)

MODERATE

No

38

9f

00

P/S OFF IMPOSSIBLE(DEVICE RESERVED)

PS(DKC)

MODERATE

No

39

90

xx

Undefined Package is mounted

Processor

MODERATE

No

39

91

xx

V-R OR SERIAL NUMBER IS INCONSISTENT

Processor

MODERATE

No

39

93

xx

REPLACE FAILED

Processor

MODERATE

No

39

9d

xx

Injustice DC voltage control

Processor

MODERATE

Yes

39

9e

xx

Injustice CEMODE

Processor

MODERATE

Yes

39

9f

xx

Injustice CEDT

Processor

MODERATE

Yes

39

b0

xx

SMA SLAVE ERROR

Processor

SERVICE

No

39b200CPU frequency setting failure

Processor

SERVICE

No

3a

0x

xx

LDEV Blockade (Effect of microcode error)

Processor

MODERATE

Yes

3c

95

00

CHB/DKB Type disagreement

Processor

MODERATE

No

3c

97

xx

iSCSI firmware update warning

Processor

MODERATE

Yes

3c

cd

xx

CHA Injustice dc voltage control

Processor

MODERATE

No

3c

ce

xx

CHA temperature abnormality

Processor

MODERATE

No

3d

cd

xx

DKA Injustice dc voltage control

Processor

MODERATE

No

3d

ce

xx

DKA temperature abnormality

Processor

MODERATE

No

41

00

xx

Format complete

Drive

SERVICE

No

41

01

00

Quick Format finish

Drive

SERVICE

No

43

4x

xx

DRIVE MEDIA ERROR6

Drive

SERVICE

No

43

5x

xx

Drive media error

Drive

SERVICE

Yes

43

ax

xx

Drive blockade (media)(with redundancy)

Drive

SERIOUS

Yes

43

bx

xx

Drive blockade (media)(with redundancy)6

Drive

SERIOUS

Yes

43

cx

xx

Drive blockade (media)(without redundancy)6

Drive

SERIOUS

Yes

43

dx

xx

Drive blockade (media)(without redundancy)

Drive

SERIOUS

Yes

45

1x

xx

CORRECTION COPY START6

Drive

SERVICE

Yes

45

2x

xx

CORRECTION COPY NORMAL END6

Drive

SERVICE

Yes

45

3x

xx

CORRECTION COPY ABNORMAL END6

Drive

SERIOUS

Yes

45

4x

xx

CORRECTION COPY DISCONTINUED6

Drive

SERVICE

No

45

5x

xx

Correction copy warning end(With blockade LDEV or some error)6

Drive

SERVICE

Yes

46

1x

xx

DYNAMIC SPARING(DRIVE COPY)START6

Drive

SERVICE

Yes

46

2x

xx

DYNAMIC SPARING(DRIVE COPY)NORMAL END6

Drive

SERVICE

Yes

46

3x

xx

DYNAMIC SPARING(DRIVE COPY)ABNORMAL END6

Drive

MODERATE

Yes

46

4x

xx

DYNAMIC SPARING(DRIVE COPY)DISCONTINUED6

Drive

SERVICE

No

46

5x

xx

Dynamic sparing warning end(With blockade LDEV or some error)(Drive copy)6

Drive

SERVICE

Yes

46

8x

xx

Collection Copy/Copyback disabled(drive replace)

Drive

MODERATE

No

46

9x

xx

Collection Copy/Copyback disabled(drive replace)

Drive

MODERATE

No

46

ax

xx

Drive Copy/Correction Copy delay

Drive

MODERATE

Yes

46

bx

xx

Drive Copy/Correction Copy delay

Drive

MODERATE

Yes

47

dx

xx

SIMF/SI Copy abnormal end

Failure with paired volumes

MODERATE

Yes

47

e5

00

All FlashCopy(R) Option abnormal end by SM volatile

Failure with paired volumes

MODERATE

Yes

47

e7

00

Forcible suspend by SM volatile (SIMF/SI)

Failure with paired volumes

MODERATE

Yes

47

ec

00

Thin Image ABNORMAL END BY SM VOLATILE

Failure with paired volumes

MODERATE

Yes

47

fx

xx

Volume Migration Abnormal End

Volume Migration

MODERATE

No3

49

10

00

CACHE WRITE PENDING RATIO IS OVER 65%

Cache

SERVICE

No

4a

80

xx

Expander Micro Exchange failed

Processor

MODERATE

No

4b

2x

xx

Compatible FlashCopy(R) ABNORMAL END

Failure with paired volumes

MODERATE

Yes

4b

3x

xx

Thin Image ABNORMAL END

Failure with paired volumes

MODERATE

Yes

4b

4x

xx

FlashCopy(R) Hierarchical memory access error

Failure with paired volumes

MODERATE

Yes

4b

6x

xx

Correction copy start

Failure with paired volumes

SERVICE

Yes

4b

7x

xx

Correction copy start

Failure with paired volumes

SERVICE

Yes

4b

8x

xx

Correction copy normal end

Failure with paired volumes

SERVICE

Yes

4b

9x

xx

Correction copy normal end

Failure with paired volumes

SERVICE

Yes

4b

ax

xx

Correction copy abnormal end

Failure with paired volumes

SERIOUS

Yes

4b

bx

xx

Correction copy abnormal end

Failure with paired volumes

SERIOUS

Yes

4b

cx

xx

Correction copy discontinued

Failure with paired volumes

SERVICE

No

4b

dx

xx

Correction copy discontinued

Failure with paired volumes

SERVICE

No

4b

ex

xx

Correction copy warning end (With blockade LDEV or some error)

Failure with paired volumes

SERVICE

Yes

4b

fx

xx

Correction copy warning end (With blockade LDEV or some error)

Failure with paired volumes

SERVICE

Yes

4c

10

xx

PDEV Erase Start

Drive

SERVICE

No

4c

20

xx

PDEV Erase Normal End

Drive

SERVICE

No

4c

30

xx

PDEV Erase Abnormal End

Drive

SERVICE

No

4c

4x

xx

Flash module drive initialization failed

Drive

MODERATE

Yes

4c

5x

xx

Flash module drive initialization failed

Drive

MODERATE

Yes

4c

6x

xx

Dynamic sparing start (Drive copy)

Drive

SERVICE

Yes

4c

7x

xx

Dynamic sparing start (Drive copy)

Drive

SERVICE

Yes

4c

8x

xx

Dynamic sparing normal end (Drive copy)

Drive

SERVICE

Yes

4c

9x

xx

Dynamic sparing normal end (Drive copy)

Drive

SERVICE

Yes

4c

ax

xx

Dynamic sparing abnormal end (Drive copy)

Drive

MODERATE

Yes

4c

bx

xx

Dynamic sparing abnormal end (Drive copy)

Drive

MODERATE

Yes

4c

cx

xx

Dynamic sparing discontinued (Drive copy)

Drive

SERVICE

No

4c

dx

xx

Dynamic sparing discontinued (Drive copy)

Drive

SERVICE

No

4c

ex

xx

Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy)

Drive

SERVICE

Yes

4c

fx

xx

Dynamic sparing warning end (With blockade LDEV or some error) (Drive copy)

Drive

SERVICE

Yes

4d

1x

xx

Differential area blocking

Drive

SERIOUS

Yes

4d

6x

xx

PDEV Erase Start

Drive

SERVICE

Yes

4d

7x

xx

PDEV Erase Start

Drive

SERVICE

Yes

4d

8x

xx

PDEV Erase Normal End

Drive

SERVICE

Yes

4d

9x

xx

PDEV Erase Normal End

Drive

SERVICE

Yes

4d

ax

xx

PDEV Erase Abnormal End

Drive

SERVICE

Yes

4d

bx

xx

PDEV Erase Abnormal End

Drive

SERVICE

Yes

50

0x

xx

Drive temporary error

Drive

SERVICE

No

50

1x

xx

DRIVE TEMPORARY ERROR

Drive

SERVICE

No

50

2x

xx

DRIVE MEDIA ERROR6

Drive

SERVICE

No

50

3x

xx

Drive media error

Drive

SERVICE

No

50

ax

xx

Flash drive End of life

Drive

SERVICE

Yes

50

bx

xx

Flash drive End of life6

Drive

SERVICE

Yes

50

cx

xx

Flash module drive End of life6

Drive

SERVICE

Yes

50

dx

xx

Flash module drive End of life

Drive

SERVICE

Yes

50

f0

00

Flash module drive micro-program version warning

Drive

MODERATE

No

60

2x

xx

Pool blocking

Thin Image pool

MODERATE

Yes

60

30

00

SM Space Warning

SM

MODERATE

Yes4

60

4x

xx

Exceeded Threshold of pool use rate

Thin Image pool

MODERATE

Yes

60

5x

xx

Actual pool use rate reaches upper limit

Thin Image pool

MODERATE

Yes

60

6x

xx

Exceeded Fixed outage Threshold of pool use rate

Thin Image pool

MODERATE

Yes

61

00

xx

BACKUP/RESTORE SM INFORMATION FAILED

SM

MODERATE

No

62

3x

xx

The DP POOL error is detected (XXX : Pool ID)

Dynamic Provisioning pool

MODERATE

Yes

62

40

00

SM(DP/TI) AREA DEPLETION

Dynamic Provisioning pool

MODERATE

Yes

62

7x

xx

The DP POOL LDEV blockade

Dynamic Provisioning pool

SERIOUS

Yes

62

80

00

DP Protect attribute setting of DRU

Dynamic Provisioning pool

SERIOUS

Yes

62

9x

xx

Exceeded Warning Threshold of DP pool use rate

Dynamic Provisioning pool

MODERATE

Yes

62

ax

xx

DP pool use rate reaches upper limit

Dynamic Provisioning pool

MODERATE

Yes

62

b0

00

Threshold of DP pool use rate remains exceeded

Dynamic Provisioning pool

MODERATE

Yes

62

cx

xx

Exceeded Depletion Threshold of DP pool use rate

Dynamic Provisioning pool

MODERATE

Yes

62

dx

xx

Exceeded Fixed outage Threshold of DPpool use rate

Dynamic Provisioning pool

MODERATE

Yes

62

ex

xx

Exceeded DP pool depletion threshold for TI pairs

Dynamic Provisioning pool

MODERATE

Yes

64

1x

xx

Tier relocation is not completed

Dynamic Tiering pool

SERVICE

Yes

66

01

00

No free encryption key

Encryption key

MODERATE

Yes

66

02

00

Remaining free encryption key warning

Encryption key

SERVICE

Yes

66

10

xx

Acquisition of encryption key from KMS failed

Encryption key

MODERATE

Yes

66

20

xx

Encryption key setting abnormality

Processor

SERIOUS

Yes

67

00

00

Warning for depletion of cache management devices

Thin Image

MODERATE

Yes

6800xx Dedupe and compression abnormality detectDKC environmentMODERATEYes

70

xx

00

Logical inconsistency

SVP failure

MODERATE

No

71

xx

00

Heap error

SVP failure

MODERATE

No

72

xx

00

File error

SVP failure

MODERATE

No

73

xx

00

LAN error

SVP failure

MODERATE

No

74

xx

xx

SSVP error

SVP failure

MODERATE

Yes

75

xx

00

Windows error

SVP failure

MODERATE

No

76

00

00

CUDG3 detected error

SVP failure

MODERATE

No

76

04

00

CUDG3 detected error

SVP failure

MODERATE

No

76

10

00

LCDG3 detected error

SVP failure

MODERATE

No

7a

00

00

NORMAL END

SVP failure

SERVICE

No

7a

01

00

ABNORMAL END(SVP)

SVP failure

SERVICE

No

7a

02

00

ABNORMAL END(MP)

SVP failure

SERVICE

No

7a

03

xx

VERSION CHK ERROR

SVP failure

SERVICE

No

7a

04

xx

Sum check error

SVP failure

SERVICE

No

7a

05

xx

HTP patch error

SVP failure

SERVICE

No

7a

10

00

WARNING(CONFIGURATION INCONSISTENCY)

SVP failure

SERVICE

No

7a

11

00

WARNING(S-SVP BUSY)

SVP failure

SERVICE

No

7a

12

xx

Warning (HTP busy)

SVP failure

SERVICE

No

7a

20

00

INTERNET DOWNLOAD ERROR

SVP failure

SERVICE

No

7a

23

00

Discontinuation by the user

SVP failure

SERVICE

No

7b

00

03

ISDN Router failure

SVP failure

MODERATE

Yes

7c

00

00

SVP reboot stop (FD Inserted)

SVP failure

MODERATE

No

7c

01

0x

Battery replacement should be scheduled

Battery

SERVICE

No

7c

02

00

Audit Log failure of Host instruction configuration change

SVP failure

MODERATE

No

7c

03

00

Audit Log FTP Transfer failed

SVP failure

MODERATE

Yes

7c

04

00

Dump Tool failed

SVP failure

SERVICE

Yes

7c

05

00

Invalid SIM data detection

SVP failure

SERVICE

No

7c0800Dump collection startsSVP failureSERVICENo
7c0900Dump collection ends normallySVP failureSERVICENo
7c0a00Dump collection ends abnormallySVP failureSERVICENo
7c0b00Cancellation of the dump collection completedSVP failureSERVICENo

7e

12

xx

MP Operating Ratio Error

Monitor

MODERATE

Yes

7e

20

xx

Loss Of Signal Count(Fibre) Excess

Monitor

MODERATE

No

7e

21

xx

Bad Received Character Count(Fibre) Excess

Monitor

MODERATE

No

7e

22

xx

Loss Of Synchronization Count(Fibre) Excess

Monitor

MODERATE

No

7e

23

xx

Link Failure Count(Fibre) Excess

Monitor

MODERATE

No

7e

24

xx

Received EOFa Count(Fibre) Excess

Monitor

MODERATE

No

7e

25

xx

Discarded Frame Count(Fibre) Excess

Monitor

MODERATE

No

7e

26

xx

Bad CRC Count(Fibre) Excess

Monitor

MODERATE

No

7e

27

xx

Protocol Error Count(Fibre) Excess

Monitor

MODERATE

No

7e

28

xx

Expired Frame Count (Fibre) Excess

Monitor

MODERATE

No

7e

29

xx

HTP/FNP Multiplicity Excess

Monitor

MODERATE

No

7e

2a

xx

FEC Un-correctable Count(Fibre) threshold exceeded

Monitor

MODERATE

No

7e

2c

xx

HTP/FNP Read Data Transfer Ratio Error

Monitor

MODERATE

No

7e

2d

xx

HTP/FNP Write Data Transfer Ratio Error

Monitor

MODERATE

No

7e

2e

xx

HTP/FNP Operating Ratio Error

Monitor

MODERATE

No

7e

30

00

Read Hit Ratio Excess

Monitor

MODERATE

No

7e

50

xx

MAC CRC Error Count(iSCSI) threshold exceeded

Monitor

MODERATE

No

7e

51

xx

IP Error Packet Count(iSCSI) threshold exceeded

Monitor

MODERATE

No

7e

52

xx

IPv6 Error Packet Count(iSCSI) threshold exceeded

Monitor

MODERATE

No

7e

53

xx

TCP Retransmit Timer Expired Count(iSCSI) exceeded

Monitor

MODERATE

No

7e

54

xx

iSCSI Header Digest Error Count(iSCSI) exceeded

Monitor

MODERATE

No

7e

55

xx

iSCSI Data Digest Error Count(iSCSI) exceeded

Monitor

MODERATE

No

7e

ax

xx

Cache Use Ratio Error

Monitor

MODERATE

No

7e

bx

xx

Cache Write Pending Ratio Error

Monitor

MODERATE

No

7e

cx

xx

Cache MCU Side File Use Ratio Error

Monitor

MODERATE

No

7f

f1

00

TCMF/TC

SVP failure

SERVICE

No

7f

f1

02

SIMF/SI

SVP failure

SERVICE

No

7f

f1

03

URMF/UR

SVP failure

SERVICE

No

7f

f1

04

TI

SVP failure

SERVICE

No

7f

f1

05

FlashCopy(R)

SVP failure

SERVICE

No

7f

f1

06

Volume Migration

SVP failure

SERVICE

No

7f

f2

xx

STANDBY SVP FAIL

SVP failure

MODERATE

No

7f

f3

xx

SVP FAIL OVER

SVP failure

MODERATE

No

7f

f7

xx

The term of validity is over

License key

MODERATE

Yes

7f

f8

xx

The capacity of validity is over

License key

MODERATE

Yes

7f

f9

xx

The PP is invalid by assumption PP invalidity

License key

MODERATE

Yes

7f

fa

0x

Synchronization time failure

SVP failure

SERVICE

Yes

ac

50

xx

DB power off

PS(DKU)

MODERATE

Yes

ac

60

00

DKC was set to power error mode

PS(DKC)

MODERATE

No

ac

61

00

DKC was released from power error mode

PS(DKC)

SERVICE

No

ac

62

00

When DKC was set to power error mode, Urgent Destaging start succeeded

PS(DKC)

SERVICE

No

ac

63

00

When DKC was set to power error mode, Urgent Destaging start failed.

PS(DKC)

MODERATE

No

af

00

xx

Injustice JP Warning

Environmental error

MODERATE

Yes

af

10

xx

MP Temperature abnormality warning

Environmental error

MODERATE

Yes

af

11

xx

External temperature warning

Environmental error

MODERATE

Yes

af

12

xx

External temperature alarm

Environmental error

MODERATE

Yes

af

13

xx

Thermal monitor warning

Environmental error

MODERATE

Yes

af

20

xx

DKCPS warning

Environmental error

MODERATE

Yes

af

21

xx

DKCPS input voltage abnormality

Environmental error

MODERATE

Yes

af

30

xx

Environmental microcontroller warning

Environmental error

MODERATE

Yes

af

31

xx

Device movement mode warning

Environmental error

MODERATE

Yes

af

33

xx

Voltage change setting warning

Environmental error

MODERATE

Yes

af

40

xx

BKM/BKMF warning

Environmental error

MODERATE

Yes

af

41

xx

Battery replacement should be scheduled

Environmental error

MODERATE

Yes

af

4d

xx

Panel switch warning

Environmental error

MODERATE

Yes

af

4e

xx

Invalid PS ON warning

Environmental error

MODERATE

Yes

af

51

xx

DBPS-1 warning

PS(DKU)

MODERATE

Yes

af

52

xx

DBPS-2 warning

PS(DKU)

MODERATE

Yes

af

61

xx

DBPS-1 input voltage abnormality

PS(DKU)

MODERATE

Yes

af

62

xx

DBPS-2 input voltage abnormality

PS(DKU)

MODERATE

Yes

af

70

00

DB External temperature warning

Environmental error

MODERATE

Yes

af

71

00

DB External temperature Alarm

Environmental error

MODERATE

Yes

af

81

xx

ENC-1 warning

Environmental error

MODERATE

Yes

af

82

xx

ENC-2 warning

Environmental error

MODERATE

Yes

af

b0

xx

HSNBX ambient temperature warning

Environmental error

MODERATE

Yes

af

b1

xx

ISW PS warning

Environmental error

MODERATE

Yes

af

b2

xx

ISW FAN warning

Environmental error

MODERATE

Yes

af

b3

xx

ISW PS input voltage abnormality

Environmental error

MODERATE

Yes

af

b4

xx

ISW warning

Environmental error

MODERATE

Yes

af

b5

xx

HSNBX thermal monitor warning

Environmental error

MODERATE

Yes

af

b6

xx

HSNBX PANEL JP setting abnormality

Environmental error

MODERATE

Yes

af

b7

xx

HSNBX PANEL JP setting warning

Environmental error

MODERATE

Yes

af

b8

xx

HSNBX PSONOFF I/F inconsistent

Environmental error

MODERATE

Yes

af

d1

xx

Battery charge EMPTY

Battery

MODERATE

No

af

d4

xx

CM Backup mounting warning

Cache

MODERATE

No

af

f0

xx

SSW data disagreement

DKC environment

MODERATE

No

af

f1

xx

GUM warning

Environmental error

MODERATE

Yes

af

f2

xx

CFM error

Processor

MODERATE

Yes

af

f3

xx

FAN warning

Environmental error

MODERATE

Yes

bf

10

1x

External temperature alarm

Environmental error

MODERATE

Yes

bf

11

1x

External high temperature warning

Environmental error

MODERATE

Yes

bf

12

1x

External low temperature warning

Environmental error

MODERATE

Yes

bf

13

1x

Internal temperature alarm

Environmental error

MODERATE

Yes

bf

14

1x

Internal temperature warning_2

Environmental error

MODERATE

Yes

bf

15

1x

Internal temperature warning_1

Environmental error

MODERATE

Yes

bf

16

1x

External high temperature warning (40 degrees C)

Environmental error

MODERATE

Yes

bf

22

xx

SSVP voltage warning (PS_SUB)

PS(DKC)

MODERATE

Yes

bf

23

xx

SSVP voltage warning (SVP supply)

PS(DKC)

MODERATE

Yes

bf

4x

1x

DKCPS warning

PS(DKC)

MODERATE

Yes

bf

6x

1x

DKCPS input voltage abnormality

PS(DKC)

MODERATE

Yes

bf

7x

1x

DKCFAN warning

Fan(DKC)

MODERATE

Yes

bf

85

a3

JP remains

Environment

MODERATE

Yes

bf

86

a3

JP remains

Environment

MODERATE

Yes

bf

9x

ax

Communication Error between SSVP and MN

DKC environment

MODERATE

No

bf

a0

ax

Logic PS voltage alarm disagreement

PS(DKC)

MODERATE

No

bf

a2

ax

External temperature disagreement

DKC environment

MODERATE

No

bf

a3

ax

Internal temperature alarm disagreement

DKC environment

MODERATE

No

bf

a4

ax

Internal temperature warning disagreement

DKC environment

MODERATE

No

bf

a5

ax

PSOFFREQ I/F disagreement

DKC environment

MODERATE

No

bf

a6

ax

PSOFFOK I/F disagreement

DKC environment

MODERATE

No

bf

a7

ax

SYSON I/F disagreement

DKC environment

MODERATE

No

bf

a8

ax

DKCPS I/F disagreement

DKC environment

MODERATE

No

bf

a9

ax

DKCPS I/F disagreement

DKC environment

MODERATE

No

bf

aa

a0

DKCPS I/F disagreement

DKC environment

MODERATE

No

bf

aa

a4

DKCPS I/F disagreement

DKC environment

MODERATE

No

bf

ab

a0

DKCPS I/F disagreement

DKC environment

MODERATE

No

bf

ab

a4

DKCPS I/F disagreement

DKC environment

MODERATE

No

bf

ac

a0

Communication Error between MN and MN

Environment

MODERATE

No

bf

ac

a1

Communication Error between MN and MN

Environment

MODERATE

No

bf

ac

a4

Communication Error between MN and MN

Environment

MODERATE

No

bf

ac

a5

Communication Error between MN and MN

Environment

MODERATE

No

bf

ad

a3

Cable connection error

Environment

MODERATE

No

bf

ad

a4

Cable connection error

Environment

MODERATE

No

bf

ae

a1

Cable connection error

Environment

MODERATE

No

bf

af

a0

PCTL/PNL abnormally

Environment

MODERATE

No

bf

af

a4

PCTL/PNL abnormally

Environment

MODERATE

No

bf

bx

ax

PCTL/PNL abnormally

DKC environment

MODERATE

No

bf

c0

10

DKC ALARM LED light on

DKC environment

SERIOUS

Yes

bf

e3

a2

Duplex SVP Setup fail

SVP failure

MODERATE

Yes

bf

e4

00

SVP FAN0 error

SVP failure

MODERATE

No

bf

e4

01

SVP FAN1 error

SVP failure

MODERATE

No

bf

e4

02

SVP FAN2 error

SVP failure

MODERATE

No

bf

e4

06

EXTENDER Hardware error

SVP failure

MODERATE

No

bf

e4

07

USB interface error

Environmental error

MODERATE

No

bf

e4

08

SVP receiving voltage error (CL1)

SVP failure

MODERATE

No

bf

e4

09

SVP receiving voltage error (CL2)

SVP failure

MODERATE

No

cf

10

xx

SAS CTL blocking

Processor

MODERATE

Yes

cf

11

xx

SAS Port (WideLink) is partially blocked

Processor

SERVICE

No

cf

12

xx

SAS PORT blocked

Processor

MODERATE

Yes

cf

13

xx

SAS-CTL Error detection

Processor

SERIOUS

Yes

cf

20

xx

PSW blockade

Processor

MODERATE

Yes

cf

22

xx

NVMe port blockade

Processor

MODERATE

Yes

cf

88

xx

CTL blocking

Processor

MODERATE

Yes

d0

0x

xx

TCMF/TC started the initial copy or out of sync for this volume

Failure with paired volumes

SERVICE

Yes

d0

1x

xx

TCMF/TC completed the initial copy for this volume

Failure with paired volumes

SERVICE

Yes

d0

2x

xx

TCMF/TC for this volume was deleted(Operation from an SVP/Web Console or a host processor)

Failure with paired volumes

SERVICE

Yes

d1

0x

xx

Remote Copy pair status change (MCU Command) (From Simplex to Duplex Pending)

Failure with paired volumes

SERVICE

Yes

d1

1x

xx

Remote Copy pair status change (MCU Command) (From Simplex to Duplex)

Failure with paired volumes

SERVICE

Yes

d1

2x

xx

Remote Copy pair status change (MCU Command) (From Duplex Pending to Duplex)

Failure with paired volumes

SERVICE

Yes

d1

3x

xx

Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend)

Failure with paired volumes

SERVICE

Yes

d1

4x

xx

Remote Copy pair status change (MCU Command) (From Duplex to Suspend)

Failure with paired volumes

SERVICE

Yes

d1

5x

xx

Remote Copy pair status change (MCU Command) (From Duplex to Simplex)

Failure with paired volumes

SERVICE

Yes

d1

6x

xx

Remote Copy pair status change (MCU Command) (From Duplex Pending to Simplex)

Failure with paired volumes

SERVICE

Yes

d1

7x

xx

Remote Copy pair status change (MCU Command) (From Suspend to Simplex)

Failure with paired volumes

SERVICE

Yes

d1

8x

xx

Remote Copy pair status change (MCU Command) (From Suspend to Duplex Pending)

Failure with paired volumes

SERVICE

Yes

d1

9x

xx

Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend(continue))

Failure with paired volumes

SERVICE

Yes

d1

ax

xx

Remote Copy pair status change (MCU Command) (From Duplex Pending to Suspend(complete))

Failure with paired volumes

SERVICE

Yes

d1

bx

xx

Remote Copy pair status change (MCU Command) (From Suspend (continue) to Suspend)

Failure with paired volumes

SERVICE

Yes

d4

0x

xx

TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the remote copy connections)

Failure with paired volumes

SERIOUS

Yes

d4

1x

xx

TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the P-VOL or the remote copy connections)

Failure with paired volumes

SERIOUS

Yes

d4

2x

xx

TCMF/TC for this volume was suspended (Due to an unrecoverable failure on the S-VOL)

Failure with paired volumes

SERIOUS

Yes

d4

4x

xx

TCMF/TC for this volume was suspended (Due to an internal error condition detected by the RCU)

Failure with paired volumes

SERIOUS

Yes

d4

5x

xx

TCMF/TC for this volume was suspended (Caused by Delete pair operation was issued to the S-VOL)

Failure with paired volumes

SERIOUS

Yes

d4

6x

xx

The S-VOL has suspended. (Due to an unrecoverable failure on the remote copy connections)

Failure with paired volumes

SERIOUS

Yes

d4

7x

xx

The S-VOL has suspended (Due to an unrecoverable failure on the S-VOL)

Failure with paired volumes

SERIOUS

Yes

d4

fx

xx

Status of the P-VOL was not consistent with the S-VOL

Failure with paired volumes

SERIOUS

Yes

d5

7x

xx

Command device operation execution of command device in state of ONLINE

Drive

SERVICE

No

d8

0x

xx

A volume to be used by the URMF/UR was defined

Failure with paired volumes

SERVICE

Yes5

d8

1x

xx

The volume being used by the URMF/UR began a copying

Failure with paired volumes

SERVICE

Yes5

d8

2x

xx

The volume being used by the URMF/UR completed a copying

Failure with paired volumes

SERVICE

Yes5

d8

3x

xx

The volume being used by the URMF/UR received a request for suspension

Failure with paired volumes

SERVICE

Yes5

d8

4x

xx

The volume being used by the URMF/UR completed a suspension transaction

Failure with paired volumes

SERVICE

Yes5

d8

5x

xx

The volume being used by the URMF/UR received a request for deletion

Failure with paired volumes

SERVICE

Yes5

d8

6x

xx

The volume being used by the URMF/UR completed the deletion

Failure with paired volumes

SERVICE

Yes5

d8

7x

xx

The volume being used by the URMF/UR was defined (placed in the PSUS status immediately)

Failure with paired volumes

SERVICE

Yes5

d8

8x

xx

A Delta volume to be used by the URMF/UR was defined

Failure with paired volumes

SERVICE

Yes5

d8

9x

xx

A Delta volume to be used by the URMF/UR was redefined

Failure with paired volumes

SERVICE

Yes5

d9

0x

xx

A change to an S-VOL was received from the MCU (From Simplex to Duplex Pending)

Failure with paired volumes

SERVICE

Yes5

d9

1x

xx

A change to an S-VOL was received from the MCU (From Simplex to Duplex)

Failure with paired volumes

SERVICE

Yes5

d9

2x

xx

A change to an S-VOL was received from the MCU (From Duplex Pending to Duplex)

Failure with paired volumes

SERVICE

Yes5

d9

3x

xx

A change to an S-VOL was received from the MCU (From Duplex Pending to Suspend)

Failure with paired volumes

SERVICE

Yes5

d9

4x

xx

A change to an S-VOL was received from the MCU (From Duplex to Suspend)

Failure with paired volumes

SERVICE

Yes5

d9

5x

xx

A change to an S-VOL was received from the MCU (From Duplex to Simplex)

Failure with paired volumes

SERVICE

Yes5

d9

6x

xx

A change to an S-VOL was received from the MCU (From Duplex Pending to Simplex)

Failure with paired volumes

SERVICE

Yes5

d9

7x

xx

A change to an S-VOL was received from the MCU (From Suspend to Simplex)

Failure with paired volumes

SERVICE

Yes5

d9

8x

xx

A change to an S-VOL was received from the MCU (From Suspend to Duplex Pending)

Failure with paired volumes

SERVICE

Yes5

d9

9x

xx

A change to an S-VOL was received from the MCU (HOLD -> PAIR)

Failure with paired volumes

SERVICE

Yes5

d9

ax

xx

A change to an S-VOL was received from the MCU (HOLD -> COPY)

Failure with paired volumes

SERVICE

Yes5

d9

bx

xx

A change to an S-VOL was received from the MCU (HOLD -> SMPL)

Failure with paired volumes

SERVICE

Yes5

d9

cx

xx

A change to an S-VOL was received from the MCU (From Simplex to Suspend)

Failure with paired volumes

SERVICE

Yes5

d9

dx

xx

A change to an S-VOL was received from the MCU (SMPL -> HOLD)

Failure with paired volumes

SERVICE

Yes5

d9

ex

xx

A change to an S-VOL was received from the MCU (PSUx(Suspend) -> HOLD)

Failure with paired volumes

SERVICE

Yes5

d9

fx

xx

A change to an S-VOL was received from the MCU (From Duplex to Duplex Pending)

Failure with paired volumes

SERVICE

Yes5

da

0x

xx

A change to an S-VOL was received from the RCU (A request for suspension was received.)

Failure with paired volumes

SERVICE

No

da

1x

xx

A change to an S-VOL was received from the RCU (A suspension transaction was completed.)

Failure with paired volumes

SERVICE

No

da

2x

xx

A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Suspend status.)

Failure with paired volumes

SERVICE

No

da

3x

xx

A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Duplex Pending status.)

Failure with paired volumes

SERVICE

No

da

4x

xx

A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Duplex status.)

Failure with paired volumes

SERVICE

No

da

5x

xx

A change to an S-VOL was received from the RCU (A pair deletion was completed.)

Failure with paired volumes

SERVICE

No

da

6x

xx

A change to an S-VOL was received from the RCU (An instruction to delete a pair was received in the Hold status.)

Failure with paired volumes

SERVICE

No

db

0x

xx

Drive port temporary error

Drive error

SERVICE

Yes

db

1x

xx

Drive port temporary error

Drive error

SERVICE

Yes

db

2x

xx

Drive port temporary error

Drive error

SERVICE

Yes

db

3x

xx

Drive port temporary error

Drive error

SERVICE

Yes

db

4x

xx

Drive port blockade

Drive error

MODERATE

Yes

db

5x

xx

Drive port blockade

Drive error

MODERATE

Yes

db

6x

xx

Drive port blockade

Drive error

MODERATE

Yes

db

7x

xx

Drive port blockade

Drive error

MODERATE

Yes

db

8x

xx

LDEV blockade (Effect of Drive port blockade)

Drive error

SERIOUS

Yes

db

9x

xx

LDEV blockade (Effect of Drive port blockade)

Drive error

SERIOUS

Yes

db

ax

xx

LDEV blockade (Effect of Drive port blockade)

Drive error

SERIOUS

Yes

db

bx

xx

LDEV blockade (Effect of Drive port blockade)

Drive error

SERIOUS

Yes

db

cx

xx

Drive Link Rate Abnormality

Drive error

SERVICE

Yes

db

dx

xx

Drive Link Rate Abnormality

Drive error

SERVICE

Yes

db

ex

xx

Drive Link Rate Abnormality

Drive error

SERVICE

Yes

db

fx

xx

Drive Link Rate Abnormality

Drive error

SERVICE

Yes

dc

0x

xx

PAIR SUSPEND(RIO PATH CLOSE)

Failure with paired volumes

SERIOUS

Yes5

dc

1x

xx

PAIR SUSPEND(MVOL ERROR)

Failure with paired volumes

SERIOUS

Yes5

dc

2x

xx

PAIR SUSPEND(RVOL ERROR)

Failure with paired volumes

SERIOUS

Yes5

dc

4x

xx

PAIR SUSPEND(SUSPEND REPORT)

Failure with paired volumes

SERIOUS

Yes5

dc

5x

xx

PAIR SUSPEND(SIMPLEX REPORT)

Failure with paired volumes

SERIOUS

Yes5

dc

6x

xx

PAIR SUSPEND(COMMUNICATION ERROR AT RCU)

Failure with paired volumes

SERIOUS

Yes5

dc

7x

xx

PAIR SUSPEND(ERROR DETECTED AT RCU)

Failure with paired volumes

SERIOUS

Yes5

dc

8x

xx

A volume being used by an S-VOL was suspended (PS OFF on the MCU side was detected)

Failure with paired volumes

SERVICE

No

dc

9x

xx

ERASE FAIL

Failure with paired volumes

SERIOUS

Yes5

dc

ax

xx

Pair suspend (Spread by error of another Affiliate)

Failure with paired volumes

SERIOUS

Yes5

dc

e0

xx

URMF/UR M-JNL Meta overflow warning

Failure with paired volumes

MODERATE

No

dc

e1

xx

URMF/UR M-JNL Data overflow warning

Failure with paired volumes

MODERATE

No

dc

e2

xx

URMF/UR R-JNL Meta overflow warning

Failure with paired volumes

MODERATE

No

dc

e3

xx

URMF/UR R-JNL Data overflow warning

Failure with paired volumes

MODERATE

No

dc

f0

xx

The URMF/UR Read JNL was interrupted for one minute (A failure on the MCU side was detected)

Failure with paired volumes

MODERATE

No

dc

f1

xx

The URMF/UR Read JNL was interrupted for five minutes (A failure on the MCU side was detected)

Failure with paired volumes

SERIOUS

No

dc

f2

xx

The URMF/UR Read JNL was interrupted for one minute (A failure on the RCU side was detected)

Failure with paired volumes

MODERATE

No

dc

f3

xx

The URMF/UR Read JNL was interrupted for five minutes (A failure on the RCU side was detected)

Failure with paired volumes

SERIOUS

No

dc

f4

xx

URMFxURMF/URxUR M-JNL Meta full Warning

Failure with paired volumes

MODERATE

No

dc

f5

xx

URMFxURMF/URxUR M-JNL Data full Warning

Failure with paired volumes

MODERATE

No

dd

0x

xx

GAD for this volume was suspended (Due to an unrecoverable failure on the remote copy connections)

Failure with paired volumes

SERIOUS

Yes

dd

1x

xx

GAD for this volume was suspended (Due to a failure on the volume)

Failure with paired volumes

SERIOUS

Yes

dd

2x

xx

GAD for this volume was suspended (Due to an internal error condition detected)

Failure with paired volumes

SERIOUS

Yes

dd

3x

xx

Status of the P-VOL was not consistent with the S-VOL

Failure with paired volumes

SERIOUS

Yes

de

e0

xx

Quorum Disk Restore

Drive

SERVICE

Yes

de

f0

xx

Quorum Disk Blocked

Drive

SERIOUS

Yes

df

6x

xx

Drive port temporary error (Drive path: Boundary 0)6

Drive

SERVICE

No

df

7x

xx

Drive port temporary error (Drive path: Boundary 1)6

Drive

SERVICE

No

df

8x

xx

DRIVE PORT BLOCKADE(PATH 0)6

Drive

MODERATE

Yes

df

9x

xx

DRIVE PORT BLOCKADE(PATH 1)6

Drive

MODERATE

Yes

df

ax

xx

LDEV blockade(Drive path: Boundary 0/Effect of Drive port blockade)6

Drive

SERIOUS

Yes

df

bx

xx

LDEV blockade(Drive path: Boundary 1/Effect of Drive port blockade)6

Drive

SERIOUS

Yes

df

cx

xx

Drive Link Rate Abnormality (Path 0)6

Drive

SERVICE

Yes

df

dx

xx

Drive Link Rate Abnormality (Path 1)6

Drive

SERVICE

Yes

df

ex

xx

Response late Drive

Drive

SERVICE

Yes

df

fx

xx

Response late Drive6

Drive

SERVICE

No

eb

0x

xx

Drive blockade (drive)(with redundancy)

Drive

SERIOUS

Yes

eb

1x

xx

Drive blockade (drive)(with redundancy)

Drive

SERIOUS

Yes

eb

2x

xx

Drive blockade (drive)(without redundancy)

Drive

SERIOUS

Yes

eb

3x

xx

Drive blockade (drive)(without redundancy)

Drive

SERIOUS

Yes

eb

4x

xx

Drive blockade (Effect of Dynamic sparing normal end)

Drive

SERVICE

Yes

eb

5x

xx

Drive blockade (Effect of Dynamic sparing normal end)

Drive

SERVICE

Yes

eb

6x

xx

Correction access occurred

Drive

SERIOUS

Yes

eb

7x

xx

Correction access occurred

Drive

SERIOUS

Yes

eb

8x

xx

Reboot stopped due to much write pending data

Drive

SERVICE

No

eb

9x

xx

Reboot stopped due to much write pending data

Drive

SERVICE

No

ef

0x

xx

Drive blockade (drive)(with redundancy)6

Drive

SERIOUS

Yes

ef

1x

xx

Drive blockade (drive) (without redundancy)6

Drive

SERIOUS

Yes

ef

2x

xx

DRIVE BLOCKADE(EFFECT OF DRIVE COPY NORMAL END)6

Drive

SERVICE

Yes

ef

4x

xx

PINNED SLOT

Drive

MODERATE

No

ef

5x

xx

Abnormal end of Write processing in External storage system

Drive

MODERATE

No

ef

8x

xx

LDEV blockade (Effect of drive blockade)

Drive

SERIOUS

Yes

ef

9x

xx

LDEV blockade (Effect of drive blockade)6

Drive

SERIOUS

Yes

ef

ax

xx

DRIVE TEMPORARY ERROR6

Drive

SERVICE

No

ef

bx

xx

Drive temporary error

Drive

SERVICE

Yes

ef

cx

xx

Correction access occurred6

Drive

SERIOUS

Yes

ef

d0

00

External storage system connection device blockade

Drive

SERIOUS

Yes

ef

d4

00

Blocking the Data Migration source device

Drive

MODERATE

No

ef

fd

xx

Expander failure

Environmental error

SERIOUS

Yes

ef

fe

xx

UNIT CONNECTION ERROR

DKC environment

MODERATE

Yes

fe

00

00

Cache battery is being charged

Cache

SERIOUS

Yes

fe

01

0x

End of Cache Write Through

Cache

SERVICE

No

fe

02

0x

Start of Cache Write Through

Cache

MODERATE

Yes

fe

03

0x

Cache SSD mounting capacity shortage

Cache

SERIOUS

No

fe

04

xx

No CHB mounted

Cache

SERIOUS

Yes

ff

21

xx

LANB blocking

Processor

MODERATE

Yes

ff

4x

xx

PINNED SLOT

Cache

MODERATE

No

ff

5x

xx

Abnormal end of Read processing in External storage system

Drive

MODERATE

No

ff

c3

0x

CACHE PACKAGE BLOCKADE PROCESSING END

Cache

SERVICE

Yes

ff

cb

xx

CTL patrol check error

Cache

SERVICE

No

ff

cc

0x

CM/CMA patrol check error

Cache

SERVICE

No

ff

cd

0x

Area is volatilized

Cache

SERVICE

No

ff

cf

xx

Package is volatilized

Cache

SERVICE

No

ff

d4

xx

Constitution definition error

Processor

MODERATE

No

ff

de

xx

WDCP loss of duplicated information

SM

SERVICE

No

ff

e4

0x

REPLACE FAILED

Cache

SERIOUS

No

ff

e7

00

Rebooted with volatilization after an instantaneous down

SM

SERIOUS

Yes

ff

e8

00

Definition/Installation mismatch

SM

ACUTE

No

ff

ea

0x

RECOVERY OF AREA BLOCKED TEMPORARILY WAS COMPLETED

SM

SERVICE

Yes

ff

ee

0x

AREA TEMPORARY BLOCKING

SM

SERVICE

Yes

ff

ef

00

Rebooted without volatilization after an instantaneous down

SM

SERVICE

No

ff

f0

xx

DIMM Correctable error

Cache

SERVICE

No

ff

f3

0x

PACKAGE BLOCKING

Cache

MODERATE

Yes

ff

f4

00

AREA BLOCKING

Cache

SERIOUS

Yes

ff

f4

01

AREA BLOCKING

Cache

SERIOUS

Yes

ff

f5

0x

Both areas failed

Cache

MODERATE

No

ff

f6

xx

CM Injustice dc voltage control

Cache

MODERATE

No

ff

f7

xx

GUM blocking

Cache

MODERATE

Yes

ff

f9

0x

REPLACE FAILED

Cache

SERVICE

No

ff

fa

xx

Battery warning

Battery

MODERATE

No

ff

fb

xx

CMBK warning

Cache

MODERATE

No

ff

fc

xx

CM Temperature abnormality warning

Cache

MODERATE

No

ff

fe

xx

Warning for forcible volatile mode

Cache

MODERATE

No

Legend:

  • YesThis SIM performs the host report.
  • NoThis SIM does not perform the host report.
  • xA hexadecimal number between 0 and f.
  1. If you select All for Notification Alert in the Edit Alert Settings window, the SNMP agent reports all SIMs. If you select Host Report, the SNMP agent reports only SIMs that perform the host report.
  2. If the DKC emulation type is I-2105 or I-2107, SIMs are reported to the host only if SOM 308 is enabled. However, SOM 308 is disabled by default.
  3. This SIM is not reported to the host, but the SNMP agent reports the SIM when Host Report is selected for Notification Alert in the Edit Alert Settings window.
  4. The SNMP agent does not report this SIM when Host Report is selected for Notification Alert in the Edit Alert Settings window, because the SIM is reported to the host, but not to the SVP.
  5. SIMs are not reported to the host by default. To enable reporting of service SIMs, see the Hitachi Universal Replicator for Mainframe User Guide.
  6. xxx: Drive location. For details, see GUID-B94C5ABE-AA65-44AB-A830-9EF33D81DE08.

Converting CDEV and RDEV numbers to box and drive numbers

To identify the location of an error, convert the CDEV and RDEV numbers to box and drive numbers.

CDEV and RDEV numbers are output as hexadecimal numbers in the following format:GUID-3CE7918F-AB93-4DB4-B8E2-022FF2CC5AF5-low.png

Base drive box number

The base drive box number is a three-digit octal number that is mapped to a specific two-digit hexadecimal CDEV number. The following table lists drive box numbers based on the first and second digits of the CDEV numbers.

Second digit of CDEV

First digit of CDEV

0_

1_

2_

3_

4_

5_

_0 000 020 040 100 120 140
_1 002 022 042 102 122 142
_2 004 024 044 104 124 144
_3 006 026 046 106 126 146
_4 001 021 041 101 121 141
_5 003 023 043 103 123 143
_6 005 025 045 105 125 145
_7 007 027 047 107 127 147
_8 010 030 050 110 130 150
_9 012 032 052 112 132 152
_A 014 034 054 114 134 154
_B 016 036 056 116 136 156
_C 011 031 051 111 131 151
_D 013 033 053 113 133 153
_E 015 035 055 115 135 155
_F 017 037 057 117 137 157

For example:

  • CDEV 42 corresponds to drive box 124.
  • CDEV 5F corresponds to drive box 157.
Base drive number

The base drive number is the RDEV number converted from hexadecimal to a two-digit decimal number. For example:

  • RDEV 0C corresponds to drive 12.
  • RDEV 22 corresponds to drive 16.
Examples of exact box and drive numbers

The format for a specific drive in a specific drive box is:

  • Drive box numberHDU-<mapped-CDEV-number>
  • Drive numberHDD<mapped-CDEV-number>-<converted-RDEV-number>

The following table provides examples of CDEV and RDEV numbers and their corresponding drive box and drive numbers.

CDEV#/RDEV# Drive box number Drive number
04/02 HDU-001 HDD001-02
3F/0A HDU-117 HDD117-10
45/15 HDU-123 HDD123-21