Physical:

  • Weight: 23 kg (51 lb.) including 3 kg rail kit assemblies and metal bezel.
  • Height: 132 mm. (5 in.)
  • Depth (bezel to PSU): 725 mm. (28.6 in.)
  • Width: 440 mm. (17.3 in.)
  • Rack space required: 3U (5.25 in.)
    NoteA rack unit, or U, is a unit of measure that is used to describe the height of equipment intended to be mounted in a rack. One rack unit is equivalent to 1.75 inches or 44.45 millimeters.

The power and cooling information is shown as follows:

NoteThe power supplies and cooling fans are hot-swappable.
Power and cooling details
Power or cooling detailHitachi NAS Platform
Voltage range (Ave./Max.)

100 VAC – 2.1/2.6A

110 VAC – 1.9/2.4A

200 VAC – 1.0/1.3A

208 VAC – 1.0/1.3A

230 VAC – 0.9/1.2A

Power supply rating495W
Average thermal (BTU/hour)710
Max. thermal (BTU/hour)887
Max. power usage260W
Heighth/width/depth

3U, 5.2 in. (132mm)/

17.3 in. (440mm)/28.6 in. (725mm)

WeightWeight 51 lbs. (23kg) incl. rail kit assemblies.
Compliance

RoHS 6

China RoHS Compliant

EU RoHS Compliant

Safety

EU: EN62368-1: 2nd edition

Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition

US: UL 62368-1

EMC

EU: EN62368-1: 2nd edition

Canada: CAN/CSA-C22.2 No.60950-1-07 2nd edition

US: UL 62368-1

Other thermal:

  • Temperature range (operational): 10° to 35° C (50° to 95° F)
  • Maximum rate of temperature change per hour (operational) 10° C (18° F)
  • Temperature range (storage): -10° to 45° C (14° to 113° F)
  • Maximum rate of temperature change per hour (storage) 15° C (27° F)
  • Temperature range (transit): -20° to 60° C (-4° to 140° F)
  • Maximum rate of temperature change per hour (transit) 20° C (36° F)

Humidity:

  • Operational: 20-80%
  • Storage: 10-90%
  • Transit: 5-95%

Noise: A-weighted Sound Power Level, Lwa (db re 1pW):

  • Typical: 71
  • Max: 81

Shock and vibration:

  • Optional random vibration: 10 to 350 Hz @ 0.18 Grms
  • Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
  • Non-operational shock: 3g 11ms, half sine

Packaged transport specification:

  • Drops from 356mm and 508mm as per ASTM D5276
  • Vibration at up to 0.53 Grms as per ASTM D4728

Altitude:

  • Maximum of 2000 meters

 