Skip to main content

We've Moved!

Product Documentation has moved to docs.hitachivantara.com
Hitachi Vantara Knowledge

Server specifications

The following specifications are for the server. Except for the power and cooling values, these specifications do not reflect differences among models; they are the maximum for all server models. For more detailed specifications of a particular model or configuration, contact your representative.

Physical:

  • Weight: 25 kg (55 lb.) with plastic bezel or 26 kg (57 lb.) with metal bezel
  • Height: 132 mm. (5 in.)
  • Width: 440 mm. (17.3 in.)
  • Rack space required: 3U (5.25 in.)
    NoteA rack unit, or U, is a unit of measure that is used to describe the height of equipment intended to be mounted in a rack. One rack unit is equivalent to 1.75 inches or 44.45 millimeters.

Power and cooling:

NoteThe power supplies and cooling fans noted in the following table are hot-swappable.

Other thermal:

  • Temperature range (operational): 10° to 35° C (50° to 95° F)
  • Maximum rate of temperature change per hour (operational) 10° C (18° F)
  • Temperature range (storage): -10° to 45° C (14° to 113° F)
  • Maximum rate of temperature change per hour (storage) 15° C (27° F)
  • Temperature range (transit): -20° to 60° C (-4° to 140° F)
  • Maximum rate of temperature change per hour (transit) 20° C (36° F)

Humidity:

  • Operational: 20-80%
  • Storage: 10-90%
  • Transit: 5-95%

Noise: A-weighted Sound Power Level, Lwa (db re 1pW):

  • Typical: 71
  • Max: 81

Shock and vibration:

  • Optional random vibration: 10 to 350 Hz @ 0.18 Grms
  • Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
  • Non-operational shock: 3g 11ms, half sine

Packaged transport specification:

  • Drops from 356mm and 508mm as per ASTM D5276
  • Vibration at up to 0.53 Grms as per ASTM D4728

Altitude:

  • Maximum of 2000 meters