Troubleshooting I/O card firmware upgrade issues
Use the following guidelines and suggested steps to help resolve I/O card firmware upgrade problems due to configuration issues.
Condition:
Unable to upgrade the I/O card firmware due to the following error:
Unable to upgrade the I/O card firmware on server <xxx.xx.xx.xxx> because of error response from the upgrade server(its workFlowId: 108). Configuration issues. Check configurations.
What it Means:
A Serial-over-LAN (SOL) communication error occurred.
Corrective Action:
Reset the BMC, and then re-run the firmware upgrade operation for the specific compute node.
- Using SSH, log on to the BMC of the compute node, and then run the following command:
reset sp
- Wait 10 minutes.
- On the Refresh icon. page, click the
- Re-run the Upgrade Firmware operation for the specific compute node.
- Using SSH, log on to the BMC of the compute node, and then run the following command: