Skip to main content
Outside service Partner
Hitachi Vantara Knowledge

Troubleshooting Fibre Channel switch functionality failures

Use the following guidelines and suggested steps to help resolve common UCP Advisor Fibre Channel switch issues.

  • Condition:

    Add FC switch throws functionality error. Error - Failed to get FC network switch status information. This functionality or a part of it is not supported for this device. Authentication failed. Please check your username and password.

  • What it means:

    The SNMP config SNMPV1 might be disabled.

  • Corrective action:

    Login to the Fibre Channel switch using SSH, then run the following command:

snmpconfig --enable snmpv1